| Motherboard | Super X11DPH-T; Super X11DPH-T; Super X11DPH-T; Super X11DPH-T |
| Processor - CPU | Dual Socket P (LGA 3647) 2nd Gen Intel® Xeon® Scalable Processors and Intel® Xeon® Scalable Processors ‡ , 3 UPI up to 10.4GT/s Support CPU TDP 70-205W |
| Processor - Note | ‡ BIOS version 3.2 or above is required to support 2nd Gen Intel® Xeon® Scalable processors (codenamed Cascade Lake-R) |
| System Memory - Memory Capacity | 16 DIMM slots Up to 4TB 3DS ECC DDR4-2933MHz † RDIMM/LRDIMM Supports Intel® Optane™ DCPMM †† |
| System Memory - Memory Type | 2933 † /2666/2400/2133MHz ECC DDR4 RDIMM/LRDIMM |
| On-Board Devices - Chipset | Intel® C622 chipset |
| On-Board Devices - SATA | SATA3 (6Gbps); RAID 0, 1, 5, 10 |
| On-Board Devices - IPMI | Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support |
| On-Board Devices - Network Controllers | Dual 10GBase-T LAN ports with Intel X722 + PHY Intel X557 |
| On-Board Devices - Video | ASPEED AST2500 BMC |
| Input Output - LAN | 2 RJ45 10GBase-T LAN ports 1 RJ45 Dedicated IPMI LAN port |
| Input Output - USB | 4 USB 3.0 ports (rear) 1 Type A |
| Input Output - Video | 1 VGA port |
| Input Output - Serial Port Header | 1 Fast UART 16550 port / 1 Header |
| PC Health Monitoring - FAN | Fans with tachometer monitoring Status monitor for speed control Pulse Width Modulated (PWM) fan connectors |
| PC Health Monitoring - Temperature | Monitoring for CPU and chassis environment Thermal Control for fan connectors |
| Chassis - Form Factor | 2U Rackmount |
| Chassis - Model | CSE-829HE1C4-R1K62LPB |
| Front Panel - Buttons | Power On/Off button System Reset button |
| Front Panel - LEDs | Power status LED Hard drive activity LED Network activity LEDs System Information LED Power fail LED |
| Expansion Slots - PCI-Express | 3 PCI-E 3.0 x16 slot 4 PCI-E 3.0 x8 slots Slot 3 occupied by controller |
| Drive Bays - Hot-swap | 16 Hot-swap 3.5" SAS3/SATA3 drive bays including 4 optional NVMe drives 2 Hot-swap 2.5" SATA3 drive bays (rear) |
| Backplane | SAS3 12Gb/s direct attached storage backplane, w/ 24x SAS3 2.5" drive slots; SAS3 12Gb/s direct attached storage backplane, w/ 24x SAS3 2.5" drive slots; SAS3 12Gb/s direct attached storage backplane, w/ 24x SAS3 2.5" drive slots; SAS3 12Gb/s direct attached storage backplane, w/ 24x SAS3 2.5" drive slots |
| System Cooling - Fans | 3 Hot-swap 8cm redundant PWM cooling fans |
| Power Supply | 1600W Redundant Power Supplies with PMBus; 1600W Redundant Power Supplies with PMBus; 1600W Redundant Power Supplies with PMBus; 1600W Redundant Power Supplies with PMBus |
| Power Supply - 12V | Max: 83.3A / Min: 0A (100-127Vac) Max: 133A / Min: 0A (200-240Vac) |
| Power Supply - Certification | Titanium Level [ Test Report ] |
| System BIOS - BIOS Type | 256Mb AMI UEFI |
| Parts List - Items Included | Part Number; Description; Motherboard / Chassis; MBD-X11DPH-T CSE-829HE1C4-R1K62LPB; Super X11DPH-T Motherboard 2U Chassis; Add-on Card / Module; AOC-S3108L-H8IR-16DD-P; AOC-S3108L-H8iR-16DD; Backplane; BPN-SAS3-826EL1-N4; 12-port 2U SAS3 12Gbps single-expander backplane, support up to 8x 3.5-inch SAS3/SATA3 HDD/SSD and 4x NVMe/SAS3/SATA3 storage devices; Backplane; BPN-SAS3-829HA-A4; 4-port internal SAS3 12Gbps backplane, support up to 4x 3.5-inch SAS3/SATA3 HDD/SSD; Cable 1; CBL-SAST-0532; MINI SAS HD,12G,INT,50CM,30AWG; MCP-260-00042-0N; STD I/O shield for X9 socket R server MB with Gasket.; MCP-220-82616-0N; 12G 2.5x2 Drive Kit w/ Status LED(216B/826B/417B/846X/847B); Heatsink / Retention; SNK-P0067PSWB; 1U Proprietary 96-mm Wide Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Heatsink / Retention; SNK-P0068APS4; 2U Active CPU Heat Sink Supporting Narrow Bolster Plate Mounting Mechanism for X11 Purley Platform; * Power Supply; PWS-1K62A-1R; AC-DC 1600W, Titanium Level, Redundancy, 1U, DC Output: +12V and +12Vs, 203 x 73.5 x 40 mm, AC Input: 90 - 264 VAC/47-63Hz, PMBus 1.2 with DSP controller,HF,RoHS/REACH; * Power Distributor; PDB-PT829H-2824; 2U standard output with 24Pin PDB support up to; * Cable 2; CBL-0160L; NEMA5-15P to C13 US power cord 16AWG 6ft, PBF (default for high watt); * Cable 3; CBL-0217L; CBL,CNTL PANEL CONVERTER,FOR SC826/846,FFC,16PIN,22CM; * FAN 1; FAN-0158L4; 80x80x38 mm, 10.5K RPM, Optional Middle Cooling Fan for X10 2U Ultra and HFT Series Servers,RoHS/REACH; * Front Panel; FPB-FP829H; Front Control Board for SC829H chassis; * Drive Tray(s); MCP-220-00075-0B; Black gen 5.5 hot-swap 3.5"; HDD tray; * Drive Tray(s); MCP-220-82902-0N; Middle tray plate for SC829H; * Drive Tray(s); MCP-220-82903-0N; Internal mid tray with handle for SC829H; * Front Panel; MCP-280-00018-0N; SC826 front control board adapter; * Rail Set; MCP-290-00053-0N-01; 36"; Rail set for Auto-latch, quick/quick, 2, 3U 17.2";W; * Drive Tray(s); MCP-290-82607-0N; 826B/216B rear dummy cover for 2 X 2.5; * Air Shroud; MCP-310-82930-0B; Mylar 1U air shroud for SC829H X11; Part Number; Description; Motherboard / Chassis; MBD-X11DPH-T CSE-829HE1C4-R1K62LPB; Super X11DPH-T Motherboard 2U Chassis; Add-on Card / Module; AOC-S3108L-H8IR-16DD-P; AOC-S3108L-H8iR-16DD; Backplane; BPN-SAS3-826EL1-N4; 12-port 2U SAS3 12Gbps single-expander backplane, support up to 8x 3.5-inch SAS3/SATA3 HDD/SSD and 4x NVMe/SAS3/SATA3 storage devices; Backplane; BPN-SAS3-829HA-A4; 4-port internal SAS3 12Gbps backplane, support up to 4x 3.5-inch SAS3/SATA3 HDD/SSD; Cable 1; CBL-SAST-0532; MINI SAS HD,12G,INT,50CM,30AWG; MCP-260-00042-0N; STD I/O shield for X9 socket R server MB with Gasket.; MCP-220-82616-0N; 12G 2.5x2 Drive Kit w/ Status LED(216B/826B/417B/846X/847B); Heatsink / Retention; SNK-P0067PSWB; 1U Proprietary 96-mm Wide Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Heatsink / Retention; SNK-P0068APS4; 2U Active CPU Heat Sink Supporting Narrow Bolster Plate Mounting Mechanism for X11 Purley Platform; * Power Supply; PWS-1K62A-1R; AC-DC 1600W, Titanium Level, Redundancy, 1U, DC Output: +12V and +12Vs, 203 x 73.5 x 40 mm, AC Input: 90 - 264 VAC/47-63Hz, PMBus 1.2 with DSP controller,HF,RoHS/REACH; * Power Distributor; PDB-PT829H-2824; 2U standard output with 24Pin PDB support up to; * Cable 2; CBL-0160L; NEMA5-15P to C13 US power cord 16AWG 6ft, PBF (default for high watt); * Cable 3; CBL-0217L; CBL,CNTL PANEL CONVERTER,FOR SC826/846,FFC,16PIN,22CM; * FAN 1; FAN-0158L4; 80x80x38 mm, 10.5K RPM, Optional Middle Cooling Fan for X10 2U Ultra and HFT Series Servers,RoHS/REACH; * Front Panel; FPB-FP829H; Front Control Board for SC829H chassis; * Drive Tray(s); MCP-220-00075-0B; Black gen 5.5 hot-swap 3.5"; HDD tray; * Drive Tray(s); MCP-220-82902-0N; Middle tray plate for SC829H; * Drive Tray(s); MCP-220-82903-0N; Internal mid tray with handle for SC829H; * Front Panel; MCP-280-00018-0N; SC826 front control board adapter; * Rail Set; MCP-290-00053-0N-01; 36"; Rail set for Auto-latch, quick/quick, 2, 3U 17.2";W; * Drive Tray(s); MCP-290-82607-0N; 826B/216B rear dummy cover for 2 X 2.5; * Air Shroud; MCP-310-82930-0B; Mylar 1U air shroud for SC829H X11; Part Number; Description; Motherboard / Chassis; MBD-X11DPH-T CSE-829HE1C4-R1K62LPB; Super X11DPH-T Motherboard 2U Chassis; Add-on Card / Module; AOC-S3108L-H8IR-16DD-P; AOC-S3108L-H8iR-16DD; Backplane; BPN-SAS3-826EL1-N4; 12-port 2U SAS3 12Gbps single-expander backplane, support up to 8x 3.5-inch SAS3/SATA3 HDD/SSD and 4x NVMe/SAS3/SATA3 storage devices; Backplane; BPN-SAS3-829HA-A4; 4-port internal SAS3 12Gbps backplane, support up to 4x 3.5-inch SAS3/SATA3 HDD/SSD; Cable 1; CBL-SAST-0532; MINI SAS HD,12G,INT,50CM,30AWG; MCP-260-00042-0N; STD I/O shield for X9 socket R server MB with Gasket.; MCP-220-82616-0N; 12G 2.5x2 Drive Kit w/ Status LED(216B/826B/417B/846X/847B); Heatsink / Retention; SNK-P0067PSWB; 1U Proprietary 96-mm Wide Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Heatsink / Retention; SNK-P0068APS4; 2U Active CPU Heat Sink Supporting Narrow Bolster Plate Mounting Mechanism for X11 Purley Platform; * Power Supply; PWS-1K62A-1R; AC-DC 1600W, Titanium Level, Redundancy, 1U, DC Output: +12V and +12Vs, 203 x 73.5 x 40 mm, AC Input: 90 - 264 VAC/47-63Hz, PMBus 1.2 with DSP controller,HF,RoHS/REACH; * Power Distributor; PDB-PT829H-2824; 2U standard output with 24Pin PDB support up to; * Cable 2; CBL-0160L; NEMA5-15P to C13 US power cord 16AWG 6ft, PBF (default for high watt); * Cable 3; CBL-0217L; CBL,CNTL PANEL CONVERTER,FOR SC826/846,FFC,16PIN,22CM; * FAN 1; FAN-0158L4; 80x80x38 mm, 10.5K RPM, Optional Middle Cooling Fan for X10 2U Ultra and HFT Series Servers,RoHS/REACH; * Front Panel; FPB-FP829H; Front Control Board for SC829H chassis; * Drive Tray(s); MCP-220-00075-0B; Black gen 5.5 hot-swap 3.5"; HDD tray; * Drive Tray(s); MCP-220-82902-0N; Middle tray plate for SC829H; * Drive Tray(s); MCP-220-82903-0N; Internal mid tray with handle for SC829H; * Front Panel; MCP-280-00018-0N; SC826 front control board adapter; * Rail Set; MCP-290-00053-0N-01; 36"; Rail set for Auto-latch, quick/quick, 2, 3U 17.2";W; * Drive Tray(s); MCP-290-82607-0N; 826B/216B rear dummy cover for 2 X 2.5; * Air Shroud; MCP-310-82930-0B; Mylar 1U air shroud for SC829H X11; Part Number; Description; Motherboard / Chassis; MBD-X11DPH-T CSE-829HE1C4-R1K62LPB; Super X11DPH-T Motherboard 2U Chassis; Add-on Card / Module; AOC-S3108L-H8IR-16DD-P; AOC-S3108L-H8iR-16DD; Backplane; BPN-SAS3-826EL1-N4; 12-port 2U SAS3 12Gbps single-expander backplane, support up to 8x 3.5-inch SAS3/SATA3 HDD/SSD and 4x NVMe/SAS3/SATA3 storage devices; Backplane; BPN-SAS3-829HA-A4; 4-port internal SAS3 12Gbps backplane, support up to 4x 3.5-inch SAS3/SATA3 HDD/SSD; Cable 1; CBL-SAST-0532; MINI SAS HD,12G,INT,50CM,30AWG; MCP-260-00042-0N; STD I/O shield for X9 socket R server MB with Gasket.; MCP-220-82616-0N; 12G 2.5x2 Drive Kit w/ Status LED(216B/826B/417B/846X/847B); Heatsink / Retention; SNK-P0067PSWB; 1U Proprietary 96-mm Wide Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Heatsink / Retention; SNK-P0068APS4; 2U Active CPU Heat Sink Supporting Narrow Bolster Plate Mounting Mechanism for X11 Purley Platform; * Power Supply; PWS-1K62A-1R; AC-DC 1600W, Titanium Level, Redundancy, 1U, DC Output: +12V and +12Vs, 203 x 73.5 x 40 mm, AC Input: 90 - 264 VAC/47-63Hz, PMBus 1.2 with DSP controller,HF,RoHS/REACH; * Power Distributor; PDB-PT829H-2824; 2U standard output with 24Pin PDB support up to; * Cable 2; CBL-0160L; NEMA5-15P to C13 US power cord 16AWG 6ft, PBF (default for high watt); * Cable 3; CBL-0217L; CBL,CNTL PANEL CONVERTER,FOR SC826/846,FFC,16PIN,22CM; * FAN 1; FAN-0158L4; 80x80x38 mm, 10.5K RPM, Optional Middle Cooling Fan for X10 2U Ultra and HFT Series Servers,RoHS/REACH; * Front Panel; FPB-FP829H; Front Control Board for SC829H chassis; * Drive Tray(s); MCP-220-00075-0B; Black gen 5.5 hot-swap 3.5"; HDD tray; * Drive Tray(s); MCP-220-82902-0N; Middle tray plate for SC829H; * Drive Tray(s); MCP-220-82903-0N; Internal mid tray with handle for SC829H; * Front Panel; MCP-280-00018-0N; SC826 front control board adapter; * Rail Set; MCP-290-00053-0N-01; 36"; Rail set for Auto-latch, quick/quick, 2, 3U 17.2";W; * Drive Tray(s); MCP-290-82607-0N; 826B/216B rear dummy cover for 2 X 2.5; * Air Shroud; MCP-310-82930-0B; Mylar 1U air shroud for SC829H X11 |
| Optional Parts List | Part Number; Description; Converter Trays; MCP-220-00118-0B MCP-220-00043-0N; Black gen-5.5 tool-less 3.5-to-2.5 converter drive tray Black hot-swap gen 4 3.5 to 2.5 HDD tray; Convert 2 Rear SATA to NVMe; MCP-220-82619-0N AOC-SLG3-2E4R-O CBL-SAST-0849; 2.5x2 NVMe Drive Kit for 216B/826B/417B/846X/847B,RoHS LP, PCIe3 x8, 2 internal Mini-SAS HD port redriver NVMe card MiniSAS HD source to OcuLink v 1.0,INT,PCIe,57CM,34AWG; 4 NVMe Drives Support; AOC-SLG3-2E4R-O CBL-SAST-0590 MCP-220-00116-0B; NVMe AOC Internal Mini-SAS HD cable for PCIe SSD NVMe, 12Gb/s, 70cm 3.5" to 2.5" NVMe drive tray; Network Card(s); AOC-S25G-m2S AOC-S40G-I2Q AOC-SG-I2 More; - - - -; Standard LP, 2x 25GbE SFP28, Mellanox ConnectX-4 LX EN Standard LP 2-port 40GbE controller, Intel Fortville XL710 Standard LP 2-port GbE, Intel 82575 AOC Compatibility Matrix; 3108 Cache Protection; BTR-TFM8G-LSICVM02 BKT-BBU-BRACKET-05; SuperCap Module Mounting PCIe Card; TPM security module (optional, not included); AOM-TPM-9670V AOM-TPM-9671V; TPM module (Vertical) TPM 2.0 TPM module (Vertical) TPM 1.2.; Intel VROC RAID Key; AOC-VROCINTMOD AOC-VROCSTNMOD AOC-VROCPREMOD; Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only) Intel VROC Standard, RAID 0, 1, 10 Intel VROC Premium, RAID 0, 1, 5, 10; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; Converter Trays; MCP-220-00118-0B MCP-220-00043-0N; Black gen-5.5 tool-less 3.5-to-2.5 converter drive tray Black hot-swap gen 4 3.5 to 2.5 HDD tray; Convert 2 Rear SATA to NVMe; MCP-220-82619-0N AOC-SLG3-2E4R-O CBL-SAST-0849; 2.5x2 NVMe Drive Kit for 216B/826B/417B/846X/847B,RoHS LP, PCIe3 x8, 2 internal Mini-SAS HD port redriver NVMe card MiniSAS HD source to OcuLink v 1.0,INT,PCIe,57CM,34AWG; 4 NVMe Drives Support; AOC-SLG3-2E4R-O CBL-SAST-0590 MCP-220-00116-0B; NVMe AOC Internal Mini-SAS HD cable for PCIe SSD NVMe, 12Gb/s, 70cm 3.5" to 2.5" NVMe drive tray; Network Card(s); AOC-S25G-m2S AOC-S40G-I2Q AOC-SG-I2 More; - - - -; Standard LP, 2x 25GbE SFP28, Mellanox ConnectX-4 LX EN Standard LP 2-port 40GbE controller, Intel Fortville XL710 Standard LP 2-port GbE, Intel 82575 AOC Compatibility Matrix; 3108 Cache Protection; BTR-TFM8G-LSICVM02 BKT-BBU-BRACKET-05; SuperCap Module Mounting PCIe Card; TPM security module (optional, not included); AOM-TPM-9670V AOM-TPM-9671V; TPM module (Vertical) TPM 2.0 TPM module (Vertical) TPM 1.2.; Intel VROC RAID Key; AOC-VROCINTMOD AOC-VROCSTNMOD AOC-VROCPREMOD; Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only) Intel VROC Standard, RAID 0, 1, 10 Intel VROC Premium, RAID 0, 1, 5, 10; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; Converter Trays; MCP-220-00118-0B MCP-220-00043-0N; Black gen-5.5 tool-less 3.5-to-2.5 converter drive tray Black hot-swap gen 4 3.5 to 2.5 HDD tray; Convert 2 Rear SATA to NVMe; MCP-220-82619-0N AOC-SLG3-2E4R-O CBL-SAST-0849; 2.5x2 NVMe Drive Kit for 216B/826B/417B/846X/847B,RoHS LP, PCIe3 x8, 2 internal Mini-SAS HD port redriver NVMe card MiniSAS HD source to OcuLink v 1.0,INT,PCIe,57CM,34AWG; 4 NVMe Drives Support; AOC-SLG3-2E4R-O CBL-SAST-0590 MCP-220-00116-0B; NVMe AOC Internal Mini-SAS HD cable for PCIe SSD NVMe, 12Gb/s, 70cm 3.5" to 2.5" NVMe drive tray; Network Card(s); AOC-S25G-m2S AOC-S40G-I2Q AOC-SG-I2 More; - - - -; Standard LP, 2x 25GbE SFP28, Mellanox ConnectX-4 LX EN Standard LP 2-port 40GbE controller, Intel Fortville XL710 Standard LP 2-port GbE, Intel 82575 AOC Compatibility Matrix; 3108 Cache Protection; BTR-TFM8G-LSICVM02 BKT-BBU-BRACKET-05; SuperCap Module Mounting PCIe Card; TPM security module (optional, not included); AOM-TPM-9670V AOM-TPM-9671V; TPM module (Vertical) TPM 2.0 TPM module (Vertical) TPM 1.2.; Intel VROC RAID Key; AOC-VROCINTMOD AOC-VROCSTNMOD AOC-VROCPREMOD; Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only) Intel VROC Standard, RAID 0, 1, 10 Intel VROC Premium, RAID 0, 1, 5, 10; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; Converter Trays; MCP-220-00118-0B MCP-220-00043-0N; Black gen-5.5 tool-less 3.5-to-2.5 converter drive tray Black hot-swap gen 4 3.5 to 2.5 HDD tray; Convert 2 Rear SATA to NVMe; MCP-220-82619-0N AOC-SLG3-2E4R-O CBL-SAST-0849; 2.5x2 NVMe Drive Kit for 216B/826B/417B/846X/847B,RoHS LP, PCIe3 x8, 2 internal Mini-SAS HD port redriver NVMe card MiniSAS HD source to OcuLink v 1.0,INT,PCIe,57CM,34AWG; 4 NVMe Drives Support; AOC-SLG3-2E4R-O CBL-SAST-0590 MCP-220-00116-0B; NVMe AOC Internal Mini-SAS HD cable for PCIe SSD NVMe, 12Gb/s, 70cm 3.5" to 2.5" NVMe drive tray; Network Card(s); AOC-S25G-m2S AOC-S40G-I2Q AOC-SG-I2 More; - - - -; Standard LP, 2x 25GbE SFP28, Mellanox ConnectX-4 LX EN Standard LP 2-port 40GbE controller, Intel Fortville XL710 Standard LP 2-port GbE, Intel 82575 AOC Compatibility Matrix; 3108 Cache Protection; BTR-TFM8G-LSICVM02 BKT-BBU-BRACKET-05; SuperCap Module Mounting PCIe Card; TPM security module (optional, not included); AOM-TPM-9670V AOM-TPM-9671V; TPM module (Vertical) TPM 2.0 TPM module (Vertical) TPM 1.2.; Intel VROC RAID Key; AOC-VROCINTMOD AOC-VROCSTNMOD AOC-VROCPREMOD; Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only) Intel VROC Standard, RAID 0, 1, 10 Intel VROC Premium, RAID 0, 1, 5, 10; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license) |
| On-Board Devices - SAS | SAS3 (12Gbps) via Broadcom 3108 AOC; HW RAID RAID 0, 1, 5, 6, 10, 50, 60 |
| Management - Software | Intel® Node Manager IPMI 2.0 NMI SPM , SUM SuperDoctor® 5 Watchdog |
| Dimensions - Width | 17.2" (437mm) |
| Dimensions - Height | 3.5" (89mm) |
| Dimensions - Depth | 27.75" (705 mm) |
| Dimensions - Available Colors | Black |
| PC Health Monitoring - CPU | Monitors for CPU Cores, Chipset Voltages, Memory. 4+1 Phase-switching voltage regulator |
| Processor - Cores | Up to 28 Cores |
| System Memory - Note | † 2933MHz in two DIMMs per channel can be achieved by using memory purchased from Supermicro †† Cascade Lake only. Contact your Supermicro sales rep for more info. |
| Operating Environment - RoHS | RoHS Compliant |
| Operating Environment - Environmental Spec | Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F) Non-operating Temperature: -40°C to 60°C (-40°F to 140°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) |
| Power Supply - Total Output Power | 1600W/1000W |
| Power Supply - DimensionW x H x L | 73.5 x 40 x 203 mm |
| Power Supply - Input | 100-127Vac / 13 - 9A / 50-60Hz 200-240Vac / 10 - 8A / 50-60Hz |
| Power Supply - 12Vsb | Max: 2.1A / Min: 0A |
| Power Supply - Output Type | 25 Pairs Gold Finger Connector |
| Dimensions - Gross Weight | 62 lbs (28.12 kg) |
| Drive Bays - Optional | 4 U.2 NVMe 2 M.2 NVMe |
| Product SKUs- Discontinued SKU EOL Please contact sales-rep for alternative options - SSG-6029P-E... | SuperStorage 6029P-E1CR16T ( Black ) |
Отзывы
Загрузка отзывов...
Добавить отзыв
Оплачивайте покупки удобным способом. В интернет-магазине доступно 3 варианта оплаты:
- Наличные при самовывозе или доставке курьером. Специалист свяжется с вами в день доставки, чтобы уточнить время и заранее подготовить сдачу с любой купюры. Вы подписываете товаросопроводительные документы, вносите денежные средства, получаете товар и чек.
- Безналичный расчет при самовывозе или оформлении в интернет-магазине: карты МИР, Visa и MasterCard. Чтобы оплатить покупку, система перенаправит вас на сервер системы ASSIST. Здесь нужно ввести номер карты, срок действия и имя держателя.
- ЮMoney при онлайн-заказе. Для совершения покупки система перенаправит вас на страницу платежного сервиса. Здесь необходимо заполнить форму по инструкции.
Экономьте время на получении заказа. В интернет-магазине доступно 4 варианта доставки:
- Курьерская доставка работает с 9.00 до 19.00. Когда товар поступит на склад, курьерская служба свяжется для уточнения деталей. Специалист предложит выбрать удобное время доставки и уточнит адрес. Осмотрите упаковку на целостность и соответствие указанной комплектации.
- Самовывоз из магазина. Список торговых точек для выбора появится в корзине. Когда заказ поступит на склад, вам придет уведомление. Для получения заказа обратитесь к сотруднику в кассовой зоне и назовите номер.
- Постамат. Когда заказ поступит на точку, на ваш телефон или e-mail придет уникальный код. Заказ нужно оплатить в терминале постамата. Срок хранения — 3 дня.
- Почтовая доставка через почту России. Когда заказ придет в отделение, на ваш адрес придет извещение о посылке. Перед оплатой вы можете оценить состояние коробки: вес, целостность. Вскрывать коробку самостоятельно вы можете только после оплаты заказа. Один заказ может содержать не больше 10 позиций и его стоимость не должна превышать 100 000 р.