Информация
  • Как купить
  • Доставка
  • Оплата
  • Реквизиты
  • Отзывы
  • Возможности
Услуги
Блог
Контакты
Акции
Компания
  • О компании
  • Лицензии
  • Отзывы
  • Документы
    info@super-micro.ru
    +7 000 000-00-00
    Заказать звонок
    super-micro.ru
    Каталог
    • X14
      X14
      • 10U
      • 1U
      • 2U
      • 3U
      • 4U
      • 5U
      • 8U
      • Fan-based Embedded
      • Mid-Tower
    • X13
      X13
      • 10U
      • 1U
      • 2U
      • 3U
      • 4U
      • 5U
      • 5U (Full Tower)
      • 6U
      • 8U
      • Compact Mini-Tower
      • Fan-based Embedded
      • Fanless Embedded
      • Mid-Tower
      • Mini-1U
      • mini-tower
      • Tower
      • Tower or 5U
      • Еще
    • X12
      X12
      • 1U
      • 2U
      • 3U
      • 4U
      • 4U Tower
      • 8U
      • Fan-based Embedded
      • Fanless Embedded
      • Full-Tower
      • Mid-Tower
      • Mini-1U
      • Mini-ITX
      • mini-tower
      • Tower
      • Еще
    • X11
      X11
      • 10U
      • 1U
      • 2U
      • 3U
      • 4U
      • 7U
      • Mid-Tower
      • Mini-ITX
    • X10
      X10
      • 1U
      • 2U
      • 3U
      • 4U
      • 7U
      • Mid-Tower
      • Mini-ITX
    • H14
      H14
      • 10U
      • 1U
      • 2U
      • 4U
      • 5U
    • H13
      H13
      • 1U
      • 2U
      • 3U
      • 4U
      • 8U
      • Mid-Tower
      • Mini-Tower
    • H12
      H12
      • 1U
      • 2U
      • 4U
      • Mid-Tower
    0 Сравнение
    0 Избранное
    0 Корзина
    Blade Mid-Tower Mini-ITX
    super-micro.ru
    Каталог
    0 Сравнение
    0 Избранное
    0 Корзина
    super-micro.ru
    Телефоны
    +7 000 000-00-00
    Заказать звонок
    0
    0
    0
    super-micro.ru
    • +7 000 000-00-00
      • Назад
      • Телефоны
      • +7 000 000-00-00
      • Заказать звонок
    • info@super-micro.ru
    • г. Москва, ул. Пушкина 19
    • Пн. – Пт.: с 9:00 до 18:00
    • 0 Сравнение
    • 0 Избранное
    • 0 Корзина
    Главная
    X11
    4U
    SSG-6049SP-DE1CR60
    SSG-6049SP-DE1CR60
    SSG-6049SP-DE1CR60
    SSG-6049SP-DE1CR60
    SSG-6049SP-DE1CR60
    SSG-6049SP-DE1CR60
    SSG-6049SP-DE1CR60
    SSG-6049SP-DE1CR60
    SSG-6049SP-DE1CR60
    SSG-6049SP-DE1CR60
    SSG-6049SP-DE1CR60
    SSG-6049SP-DE1CR60
    SSG-6049SP-DE1CR60
    SSG-6049SP-DE1CR60
    SSG-6049SP-DE1CR60

    SuperStorage 6049SP-DE1CR6

    0
    Нет отзывов
    Арт. SSG-6049SP-DE1CR60
    Продается и поддерживается только в составе готовой системы

    Все характеристики    Все товары категории  
    Нашли дешевле?
    Информация о доставке
    • Характеристики
    • Документы
    • Отзывы
    • Оплата
    • Доставка
    Технические характеристики
    PC Health Monitoring - FAN Fans with tachometer monitoring Status monitor for speed control Pulse Width Modulated (PWM) fan connectors
    PC Health Monitoring - Temperature Monitoring for CPU and chassis environment Thermal Control for fan connectors
    Chassis - Form Factor 4U Rackmount
    Chassis - Model CSE-947STS-R2K63P
    Front Panel - Buttons Power On/Off button System Reset button
    Front Panel - LEDs Power status LED Hard drive activity LED Network activity LEDs System Information LED Power fail LED
    Drive Bays - Hot-swap 60x 3.5"/2.5" Hot-swap SAS3/SATA3
    Backplane SAS3/SATA3 single expander per backplane; SAS3/SATA3 single expander per backplane; SAS3/SATA3 single expander per backplane; SAS3/SATA3 single expander per backplane
    System Cooling - Fans 6x 8cm hot-swap counter-rotate redundant PWM cooling fans
    Power Supply 2600W Redundant Power Supplies with PMBus; 2600W Redundant Power Supplies with PMBus; 2600W Redundant Power Supplies with PMBus; 2600W Redundant Power Supplies with PMBus
    Power Supply - 12V Max: 216A / Min: 0A (200-240Vac)
    Power Supply - Certification Titanium Level
    System BIOS - BIOS Type AMI UEFI
    Parts List - Items Included Part Number; Description; Motherboard / Chassis; MBD-X11DSC CSE-947STS-R2K63P; Super X11DSC Motherboard SC947S 60-Bay top load chassis w/ 2600W titanium PWS, w/o BPN; Backplane; BPN-ADP-30SAS3-1; Adapter board between Expander and HDD BPN for CSE-947H,RoHS; Backplane; BPN-SAS3-947EB; HDD Backplane (15-slot) for CSE-947H 60/90-bay top load chassis/server.,RoHS; Backplane; BPN-SAS3-947EL; SAS3 expander module for top-load 60/90-bay single/twin/SBB CSE-947 project,RoHS; Backplane; BPN-SAS3-947SB; Midplane for topload CSE-947 60/90-bay SBB/Twin/single-node system,RoHS; Drive Tray(s); MCP-220-94601-0N; SC946ED 3.5" / 2.5" tool-less HDD tray; Cable 1; CBL-0066; 39" 9 PIN COM PORT EXTENSION CABLE; Cable 2; CBL-0082; Y SPLIT SATA POWER ADAPTER 6"; Cable 3; CBL-0473L; 21CM 30AWG SATA CBL, S-S; Cable 4; CBL-OTHR-1062-25; [NR] CBL,VGA,DP15/F, to 2X7F/P2.0,25CM,RoHS; Cable 5; CBL-OTHR-1103; [NR] 60-twin,SlimlineULP x12 to SlimlineLP x8,FFC,100 OHM to 2x8,PH3.0,M, to 2x8,PH3.0,F,6A/pin,18AWG; Cable 6; CBL-PWEX-1100-25; [NR] MicroFit 2x2F/PH3.0 to 1x4F/PH5.08,25cm,16AWG; Cable 7; CBL-PWEX-1016-3; GPU,2x4F/CPU to 2x4F/CPU,P4.2, 20CM,16AWG,RoHS; Chassis Part; MCP-220-94707-0N; SC947S/SC947H DP MB tray 2U height; Power Supply; PWS-2K63A-1R; 2600W Redundant Titanium Power Supply W/PMbus 73.5x40x265mm,RoHS/REACH; Heatsink / Retention; SNK-P0068PS; 2U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Part Number; Description; Motherboard / Chassis; MBD-X11DSC CSE-947STS-R2K63P; Super X11DSC Motherboard SC947S 60-Bay top load chassis w/ 2600W titanium PWS, w/o BPN; Backplane; BPN-ADP-30SAS3-1; Adapter board between Expander and HDD BPN for CSE-947H,RoHS; Backplane; BPN-SAS3-947EB; HDD Backplane (15-slot) for CSE-947H 60/90-bay top load chassis/server.,RoHS; Backplane; BPN-SAS3-947EL; SAS3 expander module for top-load 60/90-bay single/twin/SBB CSE-947 project,RoHS; Backplane; BPN-SAS3-947SB; Midplane for topload CSE-947 60/90-bay SBB/Twin/single-node system,RoHS; Drive Tray(s); MCP-220-94601-0N; SC946ED 3.5" / 2.5" tool-less HDD tray; Cable 1; CBL-0066; 39" 9 PIN COM PORT EXTENSION CABLE; Cable 2; CBL-0082; Y SPLIT SATA POWER ADAPTER 6"; Cable 3; CBL-0473L; 21CM 30AWG SATA CBL, S-S; Cable 4; CBL-OTHR-1062-25; [NR] CBL,VGA,DP15/F, to 2X7F/P2.0,25CM,RoHS; Cable 5; CBL-OTHR-1103; [NR] 60-twin,SlimlineULP x12 to SlimlineLP x8,FFC,100 OHM to 2x8,PH3.0,M, to 2x8,PH3.0,F,6A/pin,18AWG; Cable 6; CBL-PWEX-1100-25; [NR] MicroFit 2x2F/PH3.0 to 1x4F/PH5.08,25cm,16AWG; Cable 7; CBL-PWEX-1016-3; GPU,2x4F/CPU to 2x4F/CPU,P4.2, 20CM,16AWG,RoHS; Chassis Part; MCP-220-94707-0N; SC947S/SC947H DP MB tray 2U height; Power Supply; PWS-2K63A-1R; 2600W Redundant Titanium Power Supply W/PMbus 73.5x40x265mm,RoHS/REACH; Heatsink / Retention; SNK-P0068PS; 2U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Part Number; Description; Motherboard / Chassis; MBD-X11DSC CSE-947STS-R2K63P; Super X11DSC Motherboard SC947S 60-Bay top load chassis w/ 2600W titanium PWS, w/o BPN; Backplane; BPN-ADP-30SAS3-1; Adapter board between Expander and HDD BPN for CSE-947H,RoHS; Backplane; BPN-SAS3-947EB; HDD Backplane (15-slot) for CSE-947H 60/90-bay top load chassis/server.,RoHS; Backplane; BPN-SAS3-947EL; SAS3 expander module for top-load 60/90-bay single/twin/SBB CSE-947 project,RoHS; Backplane; BPN-SAS3-947SB; Midplane for topload CSE-947 60/90-bay SBB/Twin/single-node system,RoHS; Drive Tray(s); MCP-220-94601-0N; SC946ED 3.5" / 2.5" tool-less HDD tray; Cable 1; CBL-0066; 39" 9 PIN COM PORT EXTENSION CABLE; Cable 2; CBL-0082; Y SPLIT SATA POWER ADAPTER 6"; Cable 3; CBL-0473L; 21CM 30AWG SATA CBL, S-S; Cable 4; CBL-OTHR-1062-25; [NR] CBL,VGA,DP15/F, to 2X7F/P2.0,25CM,RoHS; Cable 5; CBL-OTHR-1103; [NR] 60-twin,SlimlineULP x12 to SlimlineLP x8,FFC,100 OHM to 2x8,PH3.0,M, to 2x8,PH3.0,F,6A/pin,18AWG; Cable 6; CBL-PWEX-1100-25; [NR] MicroFit 2x2F/PH3.0 to 1x4F/PH5.08,25cm,16AWG; Cable 7; CBL-PWEX-1016-3; GPU,2x4F/CPU to 2x4F/CPU,P4.2, 20CM,16AWG,RoHS; Chassis Part; MCP-220-94707-0N; SC947S/SC947H DP MB tray 2U height; Power Supply; PWS-2K63A-1R; 2600W Redundant Titanium Power Supply W/PMbus 73.5x40x265mm,RoHS/REACH; Heatsink / Retention; SNK-P0068PS; 2U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Part Number; Description; Motherboard / Chassis; MBD-X11DSC CSE-947STS-R2K63P; Super X11DSC Motherboard SC947S 60-Bay top load chassis w/ 2600W titanium PWS, w/o BPN; Backplane; BPN-ADP-30SAS3-1; Adapter board between Expander and HDD BPN for CSE-947H,RoHS; Backplane; BPN-SAS3-947EB; HDD Backplane (15-slot) for CSE-947H 60/90-bay top load chassis/server.,RoHS; Backplane; BPN-SAS3-947EL; SAS3 expander module for top-load 60/90-bay single/twin/SBB CSE-947 project,RoHS; Backplane; BPN-SAS3-947SB; Midplane for topload CSE-947 60/90-bay SBB/Twin/single-node system,RoHS; Drive Tray(s); MCP-220-94601-0N; SC946ED 3.5" / 2.5" tool-less HDD tray; Cable 1; CBL-0066; 39" 9 PIN COM PORT EXTENSION CABLE; Cable 2; CBL-0082; Y SPLIT SATA POWER ADAPTER 6"; Cable 3; CBL-0473L; 21CM 30AWG SATA CBL, S-S; Cable 4; CBL-OTHR-1062-25; [NR] CBL,VGA,DP15/F, to 2X7F/P2.0,25CM,RoHS; Cable 5; CBL-OTHR-1103; [NR] 60-twin,SlimlineULP x12 to SlimlineLP x8,FFC,100 OHM to 2x8,PH3.0,M, to 2x8,PH3.0,F,6A/pin,18AWG; Cable 6; CBL-PWEX-1100-25; [NR] MicroFit 2x2F/PH3.0 to 1x4F/PH5.08,25cm,16AWG; Cable 7; CBL-PWEX-1016-3; GPU,2x4F/CPU to 2x4F/CPU,P4.2, 20CM,16AWG,RoHS; Chassis Part; MCP-220-94707-0N; SC947S/SC947H DP MB tray 2U height; Power Supply; PWS-2K63A-1R; 2600W Redundant Titanium Power Supply W/PMbus 73.5x40x265mm,RoHS/REACH; Heatsink / Retention; SNK-P0068PS; 2U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism
    Optional Parts List Part Number; Description; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license)
    Drive Bays - Fixed 2x 2.5" internal fixed slim SATA SSD
    Management - Software Intel® Node Manager IPMI 2.0 NMI SSM , SPM , SUM SuperDoctor® 5 Watchdog
    Dimensions - Width 17.68" (449mm)
    Dimensions - Height 6.96" (177mm)
    Dimensions - Depth 34.1" (866mm)
    Dimensions - Weight Gross Weight: 170.5 lbs (77.3kg) Net Weight: 118 lbs (53.5 kg)
    Dimensions - Available Colors Black
    System Memory per node - Memory Capacity 16 DIMM slots Up to 4TB 3DS ECC DDR4-2933MHz † RDIMM/LRDIMM Supports Intel® Optane™ DCPMM ††
    System Memory per node - Memory Type 2933 † /2666/2400/2133MHz ECC DDR4 RDIMM/LRDIMM
    Expansion Slots per node - PCI-Express 2 PCI-E 3.0 x16 (HHHL) slots 1 PCI-E 3.0 x8 (HHHL) slot
    On-Board Devices per node - Chipset Intel® C621 chipset
    On-Board Devices per node - IPMI Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support
    On-Board Devices per node - Graphics ASPEED AST2500 BMC
    Input Output per node - LAN 2 RJ45 10GBase-T LAN ports 1 Dedicated IPMI LAN port
    PC Health Monitoring - CPU Monitors for CPU Cores, Chipset Voltages, Memory. 4+1 Phase-switching voltage regulator
    Operating Environment - RoHS RoHS Compliant
    Operating Environment - Environmental Spec Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F) Non-operating Temperature: -40°C to 60°C (-40°F to 140°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing)
    Power Supply - Total Output Power 2600W: 200 – 240Vac 2600W: 200 – 220Vdc (CQC only)
    Power Supply - DimensionW x H x L 73.5 x 40 x 265 mm
    Power Supply - 12Vsb Max: 3.5A / Min: 0A
    Power Supply - Output Type 25 Pairs Gold Finger Connector
    Input Output per node - USB 2 USB 3.0 ports (rear) 1 Type A
    Input Output per node - VGA 1 VGA D-Sub connector port
    Power Supply - AC Input Frequency 50-60Hz
    Drive Bays - M2 2x NVMe M.2 (form factor: 2280 and 22110)
    On-Board Devices per node - Network Controllers Dual 10GBase-T LAN ports via Intel X550
    System Memory per node - Note † 2933MHz in two DIMMs per channel can be achieved by using memory purchased from Supermicro †† Cascade Lake only. Contact your Supermicro sales rep for more info.
    SAS Controllers choose one of the following Part Number; Description; Add-on Module 3616 (IT mode) (per node); AOM-S3616-S-O; Storage 3616 controller for serviceable 60/90 bay systems. This has two 3616 controller chips, PCI switch, 2x NVMe M.2 (Form factors: 2280 and 22110), RoHS; Add-on Card 3108 (HW RAID) (occupies PCI-E slots 1 and 2) (per node); AOC-S3108L-H8iR; LSI 3108 based SAS3 RAID, 12Gb, 8 internal ports, 240HDD - RAID 0, 1, 10, 5, 6, 50, 60, Gen3 x8 Standard Low Profile; AOM-SADPT-S; Bypass card with PCI switch, 2x NVMe M.2 (Form factors: 2280 and 22110) and 2x slimSAS x8 HD connectors, RoHS; CBL-SAST-1229-100; Slimline x8 (STR) to 2x MiniSAS HD x4 (STR),25CM,100 OHM; MCP-240-94711-0N + BTR-TFM8G-LSICVM02 (optional); SC947 MB Node Supercap holder module,RoHS Supercap/TFM Unit for cached data protection; Add-on Card 3908 (HW RAID) (occupies PCI-E slot 1); AOC-S3908L-H8IR; LSI 3908 based SAS3 RAID, 12Gb, 8 internal ports, 240HDD - RAID 0, 1, 10, 5, 6, 50, 60, Gen3 x8 Standard Low Profile; AOM-SADPT-S; Bypass card with PCI switch, 2x NVMe M.2 (Form factors: 2280 and 22110) and 2x slimSAS x8 HD connectors, RoHS; CBL-SAST-1301-100; Slimline x8 (STR) to 2x SLL x8 STR,14/14CM,100 Ohm,RoHS; MCP-240-94711-0N + BTR-CVPM05 (optional); SC947 MB Node Supercap holder module,RoHS Broadcom 05-50039-00 CacheVault w/ 24" Remote Extender; Part Number; Description; Add-on Module 3616 (IT mode) (per node); AOM-S3616-S-O; Storage 3616 controller for serviceable 60/90 bay systems. This has two 3616 controller chips, PCI switch, 2x NVMe M.2 (Form factors: 2280 and 22110), RoHS; Add-on Card 3108 (HW RAID) (occupies PCI-E slots 1 and 2) (per node); AOC-S3108L-H8iR; LSI 3108 based SAS3 RAID, 12Gb, 8 internal ports, 240HDD - RAID 0, 1, 10, 5, 6, 50, 60, Gen3 x8 Standard Low Profile; AOM-SADPT-S; Bypass card with PCI switch, 2x NVMe M.2 (Form factors: 2280 and 22110) and 2x slimSAS x8 HD connectors, RoHS; CBL-SAST-1229-100; Slimline x8 (STR) to 2x MiniSAS HD x4 (STR),25CM,100 OHM; MCP-240-94711-0N + BTR-TFM8G-LSICVM02 (optional); SC947 MB Node Supercap holder module,RoHS Supercap/TFM Unit for cached data protection; Add-on Card 3908 (HW RAID) (occupies PCI-E slot 1); AOC-S3908L-H8IR; LSI 3908 based SAS3 RAID, 12Gb, 8 internal ports, 240HDD - RAID 0, 1, 10, 5, 6, 50, 60, Gen3 x8 Standard Low Profile; AOM-SADPT-S; Bypass card with PCI switch, 2x NVMe M.2 (Form factors: 2280 and 22110) and 2x slimSAS x8 HD connectors, RoHS; CBL-SAST-1301-100; Slimline x8 (STR) to 2x SLL x8 STR,14/14CM,100 Ohm,RoHS; MCP-240-94711-0N + BTR-CVPM05 (optional); SC947 MB Node Supercap holder module,RoHS Broadcom 05-50039-00 CacheVault w/ 24" Remote Extender; Part Number; Description; Add-on Module 3616 (IT mode) (per node); AOM-S3616-S-O; Storage 3616 controller for serviceable 60/90 bay systems. This has two 3616 controller chips, PCI switch, 2x NVMe M.2 (Form factors: 2280 and 22110), RoHS; Add-on Card 3108 (HW RAID) (occupies PCI-E slots 1 and 2) (per node); AOC-S3108L-H8iR; LSI 3108 based SAS3 RAID, 12Gb, 8 internal ports, 240HDD - RAID 0, 1, 10, 5, 6, 50, 60, Gen3 x8 Standard Low Profile; AOM-SADPT-S; Bypass card with PCI switch, 2x NVMe M.2 (Form factors: 2280 and 22110) and 2x slimSAS x8 HD connectors, RoHS; CBL-SAST-1229-100; Slimline x8 (STR) to 2x MiniSAS HD x4 (STR),25CM,100 OHM; MCP-240-94711-0N + BTR-TFM8G-LSICVM02 (optional); SC947 MB Node Supercap holder module,RoHS Supercap/TFM Unit for cached data protection; Add-on Card 3908 (HW RAID) (occupies PCI-E slot 1); AOC-S3908L-H8IR; LSI 3908 based SAS3 RAID, 12Gb, 8 internal ports, 240HDD - RAID 0, 1, 10, 5, 6, 50, 60, Gen3 x8 Standard Low Profile; AOM-SADPT-S; Bypass card with PCI switch, 2x NVMe M.2 (Form factors: 2280 and 22110) and 2x slimSAS x8 HD connectors, RoHS; CBL-SAST-1301-100; Slimline x8 (STR) to 2x SLL x8 STR,14/14CM,100 Ohm,RoHS; MCP-240-94711-0N + BTR-CVPM05 (optional); SC947 MB Node Supercap holder module,RoHS Broadcom 05-50039-00 CacheVault w/ 24" Remote Extender; Part Number; Description; Add-on Module 3616 (IT mode) (per node); AOM-S3616-S-O; Storage 3616 controller for serviceable 60/90 bay systems. This has two 3616 controller chips, PCI switch, 2x NVMe M.2 (Form factors: 2280 and 22110), RoHS; Add-on Card 3108 (HW RAID) (occupies PCI-E slots 1 and 2) (per node); AOC-S3108L-H8iR; LSI 3108 based SAS3 RAID, 12Gb, 8 internal ports, 240HDD - RAID 0, 1, 10, 5, 6, 50, 60, Gen3 x8 Standard Low Profile; AOM-SADPT-S; Bypass card with PCI switch, 2x NVMe M.2 (Form factors: 2280 and 22110) and 2x slimSAS x8 HD connectors, RoHS; CBL-SAST-1229-100; Slimline x8 (STR) to 2x MiniSAS HD x4 (STR),25CM,100 OHM; MCP-240-94711-0N + BTR-TFM8G-LSICVM02 (optional); SC947 MB Node Supercap holder module,RoHS Supercap/TFM Unit for cached data protection; Add-on Card 3908 (HW RAID) (occupies PCI-E slot 1); AOC-S3908L-H8IR; LSI 3908 based SAS3 RAID, 12Gb, 8 internal ports, 240HDD - RAID 0, 1, 10, 5, 6, 50, 60, Gen3 x8 Standard Low Profile; AOM-SADPT-S; Bypass card with PCI switch, 2x NVMe M.2 (Form factors: 2280 and 22110) and 2x slimSAS x8 HD connectors, RoHS; CBL-SAST-1301-100; Slimline x8 (STR) to 2x SLL x8 STR,14/14CM,100 Ohm,RoHS; MCP-240-94711-0N + BTR-CVPM05 (optional); SC947 MB Node Supercap holder module,RoHS Broadcom 05-50039-00 CacheVault w/ 24" Remote Extender
    Motherboard Two per system Super X11DSC; Super X11DSC; Super X11DSC; Super X11DSC
    Product SKUs - SSG-6049SP-DE1CR60 SuperStorage 6049SP-DE1CR60 ( Black )
    ProcessorCache per node - CPU Dual Socket P (LGA 3647) 2nd Gen Intel® Xeon® Scalable Processors and Intel® Xeon® Scalable Processors ‡ , 3 UPI up to 10.4GT/s Support CPU TDP 70-205W
    ProcessorCache per node - Cores Up to 28 Cores
    ProcessorCache per node - Note ‡ BIOS version 3.2 or above is required to support 2nd Gen Intel® Xeon® Scalable processors (codenamed Cascade Lake-R)
    On-Board Devices per node - Storage Dual Broadcom 3616 controllers (IT Mode) or Broadcom 3108 (H/W RAID)
    Input Output per node - Serial Port Header 1 Fast UART 16550 port / 1 Header
    MNL-2385
    28,6 Мб
    datasheet_H12_2U2NodeGPU
    999,9 Кб
    Отзывы
    Загрузка отзывов...
    Нет отзывов
    Добавить отзыв

    Оплачивайте покупки удобным способом. В интернет-магазине доступно 3 варианта оплаты:

    1. Наличные при самовывозе или доставке курьером. Специалист свяжется с вами в день доставки, чтобы уточнить время и заранее подготовить сдачу с любой купюры. Вы подписываете товаросопроводительные документы, вносите денежные средства, получаете товар и чек.
    2. Безналичный расчет при самовывозе или оформлении в интернет-магазине: карты МИР, Visa и MasterCard. Чтобы оплатить покупку, система перенаправит вас на сервер системы ASSIST. Здесь нужно ввести номер карты, срок действия и имя держателя.
    3. ЮMoney при онлайн-заказе. Для совершения покупки система перенаправит вас на страницу платежного сервиса. Здесь необходимо заполнить форму по инструкции.

    Экономьте время на получении заказа. В интернет-магазине доступно 4 варианта доставки:

    1. Курьерская доставка работает с 9.00 до 19.00. Когда товар поступит на склад, курьерская служба свяжется для уточнения деталей. Специалист предложит выбрать удобное время доставки и уточнит адрес. Осмотрите упаковку на целостность и соответствие указанной комплектации.
    2. Самовывоз из магазина. Список торговых точек для выбора появится в корзине. Когда заказ поступит на склад, вам придет уведомление. Для получения заказа обратитесь к сотруднику в кассовой зоне и назовите номер.
    3. Постамат. Когда заказ поступит на точку, на ваш телефон или e-mail придет уникальный код. Заказ нужно оплатить в терминале постамата. Срок хранения — 3 дня.
    4. Почтовая доставка через почту России. Когда заказ придет в отделение, на ваш адрес придет извещение о посылке. Перед оплатой вы можете оценить состояние коробки: вес, целостность. Вскрывать коробку самостоятельно вы можете только после оплаты заказа. Один заказ может содержать не больше 10 позиций и его стоимость не должна превышать 100 000 р.