| Motherboard | Super X11DPT-BH; Super X11DPT-BH; Super X11DPT-BH; Super X11DPT-BH |
| Processor - CPU | Dual Socket P (LGA 3647) 2nd Gen Intel® Xeon® Scalable Processors and Intel® Xeon® Scalable Processors ‡ , 3 UPI up to 10.4GT/s Support CPU TDP 70-205W * |
| Processor - Note | ‡ BIOS version 3.2 or above is required to support 2nd Gen Intel® Xeon® Scalable processors (codenamed Cascade Lake-R). Extended thermal solutions may be required to support CPUs higher than 165W TDP, please contact Supermicro Technical Support for additional information. |
| System Memory - Memory Capacity | 24 DIMM slots Up to 6TB 3DS ECC DDR4-2933MHz † RDIMM/LRDIMM Supports Intel® Optane™ DCPMM †† |
| System Memory - Memory Type | 2933 † /2666/2400/2133MHz ECC DDR4 RDIMM/LRDIMM |
| On-Board Devices - Chipset | Intel® C621 chipset |
| On-Board Devices - IPMI | Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support |
| On-Board Devices - Video | ASPEED AST2500 BMC |
| PC Health Monitoring - FAN | Fans with tachometer monitoring Status monitor for speed control Pulse Width Modulated (PWM) fan connectors |
| PC Health Monitoring - Temperature | Monitoring for CPU and chassis environment Thermal Control for fan connectors |
| Chassis - Form Factor | 2U Rackmount |
| Chassis - Model | CSE-217BHQ+-R2K60FP |
| Dimensions and Weight - Height | 3.47" (88mm) |
| Dimensions and Weight - Width | 17.6" (447mm) |
| Dimensions and Weight - Depth | 28.75" (730mm) |
| Dimensions and Weight - Package | 24.65" (H) x 9.76" (W) x 45.28" (D) |
| Dimensions and Weight - Weight | Gross Weight: 85 lbs (38.6kg) Net Weight: 54.5 lbs (24.7 kg) |
| Dimensions and Weight - Available Colors | Black |
| Front Panel - Buttons | Power On/Off button UID button |
| Front Panel - LEDs | Power status LED HDD activity LED Network activity LEDs Universal Information (UID) LED |
| System Cooling - Fans | 16 Heavy duty 40x56mm PWM fans with air shroud (4 fans per node) |
| System BIOS - BIOS Type | AMI 32Mb SPI Flash ROM |
| Parts List - Items Included | Part Number; Description; Motherboard / Chassis; MBD-X11DPT-BH CSE-217BHQ+-R2K60FP; Super X11DPT-BH Motherboard 2U Chassis; Backplane; BPN-ADP-6NVME3-1UB; 6x NVMe ports and 50A power sourcing daughter card for Big Twin; Backplane; BPN-NVME3-217BHQ; 2U 24-Port 4-Node NVMe Backplane Support 6x2.5; Cable 1; CBL-PWCD-0376-IS; PWCD,US,IEC60320 C19 TO C20,940mm (3ft),14AWG,15A,250V,Black; Drive Tray(s); MCP-220-00127-0B-BULK; Black gen3 Hotswap 2.5 NVMe drive tray, Orange tab/Lock/Bulk; Air Shroud; MCP-310-21719-0B; Bigtwin mylar air shroud for X11DPT-BH (4CM fan chassis); Air Shroud; MCP-310-21720-0B; Bigtwin plastic air shroud for X11DPT-BH (4CM fan chassis); Manual; MNL-2126-QRG; 2029BZ-HNR Quick Reference Guide; Riser Card; RSC-P-6; RSC-P-6 (1U LHS TwinPro RSC with 1 PCI-Ex16),RoHS; Riser Card; RSC-R1UTP-E16R; 1U RHS TwinPro Riser card with one PCI-E x16 slot; Heatsink / Retention; SNK-P0067PSMB; 1U Passive High Performance Front CPU Heat Sink w/ an 18-mm Wide Middle Air Channel for X11 Purley Platform Equipped w/ a Narrow Retention Mechanism/Bolster; Heatsink / Retention; SNK-P0071VS; 1U Proprietary Passive CPU Heat Sink (124 mm Long) for SYS-2029BZ-HNR Series Servers (X11 2U4N 3UPI Big Twin); Power Supply; PWS-2K60A-1R; 1U 2600W Redundant Titanium PWS, 45(W) X 40(H) X 480(L); Cooling Fans; FAN-0193L4; 40x40x56 mm, 23.3K-20.3K RPM, Counter-rotating Fan; 4 fans per node x 4 nodes; Part Number; Description; Motherboard / Chassis; MBD-X11DPT-BH CSE-217BHQ+-R2K60FP; Super X11DPT-BH Motherboard 2U Chassis; Backplane; BPN-ADP-6NVME3-1UB; 6x NVMe ports and 50A power sourcing daughter card for Big Twin; Backplane; BPN-NVME3-217BHQ; 2U 24-Port 4-Node NVMe Backplane Support 6x2.5; Cable 1; CBL-PWCD-0376-IS; PWCD,US,IEC60320 C19 TO C20,940mm (3ft),14AWG,15A,250V,Black; Drive Tray(s); MCP-220-00127-0B-BULK; Black gen3 Hotswap 2.5 NVMe drive tray, Orange tab/Lock/Bulk; Air Shroud; MCP-310-21719-0B; Bigtwin mylar air shroud for X11DPT-BH (4CM fan chassis); Air Shroud; MCP-310-21720-0B; Bigtwin plastic air shroud for X11DPT-BH (4CM fan chassis); Manual; MNL-2126-QRG; 2029BZ-HNR Quick Reference Guide; Riser Card; RSC-P-6; RSC-P-6 (1U LHS TwinPro RSC with 1 PCI-Ex16),RoHS; Riser Card; RSC-R1UTP-E16R; 1U RHS TwinPro Riser card with one PCI-E x16 slot; Heatsink / Retention; SNK-P0067PSMB; 1U Passive High Performance Front CPU Heat Sink w/ an 18-mm Wide Middle Air Channel for X11 Purley Platform Equipped w/ a Narrow Retention Mechanism/Bolster; Heatsink / Retention; SNK-P0071VS; 1U Proprietary Passive CPU Heat Sink (124 mm Long) for SYS-2029BZ-HNR Series Servers (X11 2U4N 3UPI Big Twin); Power Supply; PWS-2K60A-1R; 1U 2600W Redundant Titanium PWS, 45(W) X 40(H) X 480(L); Cooling Fans; FAN-0193L4; 40x40x56 mm, 23.3K-20.3K RPM, Counter-rotating Fan; 4 fans per node x 4 nodes; Part Number; Description; Motherboard / Chassis; MBD-X11DPT-BH CSE-217BHQ+-R2K60FP; Super X11DPT-BH Motherboard 2U Chassis; Backplane; BPN-ADP-6NVME3-1UB; 6x NVMe ports and 50A power sourcing daughter card for Big Twin; Backplane; BPN-NVME3-217BHQ; 2U 24-Port 4-Node NVMe Backplane Support 6x2.5; Cable 1; CBL-PWCD-0376-IS; PWCD,US,IEC60320 C19 TO C20,940mm (3ft),14AWG,15A,250V,Black; Drive Tray(s); MCP-220-00127-0B-BULK; Black gen3 Hotswap 2.5 NVMe drive tray, Orange tab/Lock/Bulk; Air Shroud; MCP-310-21719-0B; Bigtwin mylar air shroud for X11DPT-BH (4CM fan chassis); Air Shroud; MCP-310-21720-0B; Bigtwin plastic air shroud for X11DPT-BH (4CM fan chassis); Manual; MNL-2126-QRG; 2029BZ-HNR Quick Reference Guide; Riser Card; RSC-P-6; RSC-P-6 (1U LHS TwinPro RSC with 1 PCI-Ex16),RoHS; Riser Card; RSC-R1UTP-E16R; 1U RHS TwinPro Riser card with one PCI-E x16 slot; Heatsink / Retention; SNK-P0067PSMB; 1U Passive High Performance Front CPU Heat Sink w/ an 18-mm Wide Middle Air Channel for X11 Purley Platform Equipped w/ a Narrow Retention Mechanism/Bolster; Heatsink / Retention; SNK-P0071VS; 1U Proprietary Passive CPU Heat Sink (124 mm Long) for SYS-2029BZ-HNR Series Servers (X11 2U4N 3UPI Big Twin); Power Supply; PWS-2K60A-1R; 1U 2600W Redundant Titanium PWS, 45(W) X 40(H) X 480(L); Cooling Fans; FAN-0193L4; 40x40x56 mm, 23.3K-20.3K RPM, Counter-rotating Fan; 4 fans per node x 4 nodes; Part Number; Description; Motherboard / Chassis; MBD-X11DPT-BH CSE-217BHQ+-R2K60FP; Super X11DPT-BH Motherboard 2U Chassis; Backplane; BPN-ADP-6NVME3-1UB; 6x NVMe ports and 50A power sourcing daughter card for Big Twin; Backplane; BPN-NVME3-217BHQ; 2U 24-Port 4-Node NVMe Backplane Support 6x2.5; Cable 1; CBL-PWCD-0376-IS; PWCD,US,IEC60320 C19 TO C20,940mm (3ft),14AWG,15A,250V,Black; Drive Tray(s); MCP-220-00127-0B-BULK; Black gen3 Hotswap 2.5 NVMe drive tray, Orange tab/Lock/Bulk; Air Shroud; MCP-310-21719-0B; Bigtwin mylar air shroud for X11DPT-BH (4CM fan chassis); Air Shroud; MCP-310-21720-0B; Bigtwin plastic air shroud for X11DPT-BH (4CM fan chassis); Manual; MNL-2126-QRG; 2029BZ-HNR Quick Reference Guide; Riser Card; RSC-P-6; RSC-P-6 (1U LHS TwinPro RSC with 1 PCI-Ex16),RoHS; Riser Card; RSC-R1UTP-E16R; 1U RHS TwinPro Riser card with one PCI-E x16 slot; Heatsink / Retention; SNK-P0067PSMB; 1U Passive High Performance Front CPU Heat Sink w/ an 18-mm Wide Middle Air Channel for X11 Purley Platform Equipped w/ a Narrow Retention Mechanism/Bolster; Heatsink / Retention; SNK-P0071VS; 1U Proprietary Passive CPU Heat Sink (124 mm Long) for SYS-2029BZ-HNR Series Servers (X11 2U4N 3UPI Big Twin); Power Supply; PWS-2K60A-1R; 1U 2600W Redundant Titanium PWS, 45(W) X 40(H) X 480(L); Cooling Fans; FAN-0193L4; 40x40x56 mm, 23.3K-20.3K RPM, Counter-rotating Fan; 4 fans per node x 4 nodes |
| Optional Parts List | Part Number; Description; TPM security module; AOM-TPM-9670H-S; SPI Capable TPM 2.0 Provisioned for Server, Horizontal Form Factor; TPM security module; AOM-TPM-9671H-S; SPI Capable TPM 1.2 Provisioned for Server, Horizontal Form Factor; Intel VROC RAID Key; AOC-VROCINTMOD AOC-VROCSTNMOD AOC-VROCPREMOD; Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only) Intel VROC Standard, RAID 0, 1, 10 Intel VROC Premium, RAID 0, 1, 5, 10; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); SuperDOM; Supermicro SATA DOM Solutions [ Details ]; Network Card(s); AOC-S40G-i2Q AOC-SGP-i2 AOC-SGP-i4 AOC-STG-b4S AOC-STGN-i2S AOC-STGN-i1S AOC-STG-i2T AOC-STG-i2; - - - - - - - -; Standard LP 2-port 40GbE controller, based on Intel Fortville XL710 Standard LP, 2x GbE RJ45, PCI-E x4, Intel i350AM2 Standard LP, 4x GbE RJ45, PCI-E x4, Intel i350 Standard LP, 4x 10GbE SFP+, PCI-E x8, Broadcom BCM57840S Standard LP, 2x 10GbE SFP+, PCI-E x8, Intel 82599ES Standard LP, 1x 10GbE SFP+, PCI-E x8, Intel 82599EN Standard LP, 2x 10GbE RJ45, PCI-E x8, Intel X540 Standard LP, 2x 10GbE CX4, PCI-E x8, Intel 82598EB; Carrier Card(s); AOC-SMG3-2H8M2-B AOC-SMG2-2TM2; 2x Hybrid NVMe/SATA M.2 carrier for BigTwin,HF,RoHS 2x SATA M.2 RAID 1 adapter for BigTwin,HF,RoHS; Part Number; Description; TPM security module; AOM-TPM-9670H-S; SPI Capable TPM 2.0 Provisioned for Server, Horizontal Form Factor; TPM security module; AOM-TPM-9671H-S; SPI Capable TPM 1.2 Provisioned for Server, Horizontal Form Factor; Intel VROC RAID Key; AOC-VROCINTMOD AOC-VROCSTNMOD AOC-VROCPREMOD; Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only) Intel VROC Standard, RAID 0, 1, 10 Intel VROC Premium, RAID 0, 1, 5, 10; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); SuperDOM; Supermicro SATA DOM Solutions [ Details ]; Network Card(s); AOC-S40G-i2Q AOC-SGP-i2 AOC-SGP-i4 AOC-STG-b4S AOC-STGN-i2S AOC-STGN-i1S AOC-STG-i2T AOC-STG-i2; - - - - - - - -; Standard LP 2-port 40GbE controller, based on Intel Fortville XL710 Standard LP, 2x GbE RJ45, PCI-E x4, Intel i350AM2 Standard LP, 4x GbE RJ45, PCI-E x4, Intel i350 Standard LP, 4x 10GbE SFP+, PCI-E x8, Broadcom BCM57840S Standard LP, 2x 10GbE SFP+, PCI-E x8, Intel 82599ES Standard LP, 1x 10GbE SFP+, PCI-E x8, Intel 82599EN Standard LP, 2x 10GbE RJ45, PCI-E x8, Intel X540 Standard LP, 2x 10GbE CX4, PCI-E x8, Intel 82598EB; Carrier Card(s); AOC-SMG3-2H8M2-B AOC-SMG2-2TM2; 2x Hybrid NVMe/SATA M.2 carrier for BigTwin,HF,RoHS 2x SATA M.2 RAID 1 adapter for BigTwin,HF,RoHS; Part Number; Description; TPM security module; AOM-TPM-9670H-S; SPI Capable TPM 2.0 Provisioned for Server, Horizontal Form Factor; TPM security module; AOM-TPM-9671H-S; SPI Capable TPM 1.2 Provisioned for Server, Horizontal Form Factor; Intel VROC RAID Key; AOC-VROCINTMOD AOC-VROCSTNMOD AOC-VROCPREMOD; Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only) Intel VROC Standard, RAID 0, 1, 10 Intel VROC Premium, RAID 0, 1, 5, 10; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); SuperDOM; Supermicro SATA DOM Solutions [ Details ]; Network Card(s); AOC-S40G-i2Q AOC-SGP-i2 AOC-SGP-i4 AOC-STG-b4S AOC-STGN-i2S AOC-STGN-i1S AOC-STG-i2T AOC-STG-i2; - - - - - - - -; Standard LP 2-port 40GbE controller, based on Intel Fortville XL710 Standard LP, 2x GbE RJ45, PCI-E x4, Intel i350AM2 Standard LP, 4x GbE RJ45, PCI-E x4, Intel i350 Standard LP, 4x 10GbE SFP+, PCI-E x8, Broadcom BCM57840S Standard LP, 2x 10GbE SFP+, PCI-E x8, Intel 82599ES Standard LP, 1x 10GbE SFP+, PCI-E x8, Intel 82599EN Standard LP, 2x 10GbE RJ45, PCI-E x8, Intel X540 Standard LP, 2x 10GbE CX4, PCI-E x8, Intel 82598EB; Carrier Card(s); AOC-SMG3-2H8M2-B AOC-SMG2-2TM2; 2x Hybrid NVMe/SATA M.2 carrier for BigTwin,HF,RoHS 2x SATA M.2 RAID 1 adapter for BigTwin,HF,RoHS; Part Number; Description; TPM security module; AOM-TPM-9670H-S; SPI Capable TPM 2.0 Provisioned for Server, Horizontal Form Factor; TPM security module; AOM-TPM-9671H-S; SPI Capable TPM 1.2 Provisioned for Server, Horizontal Form Factor; Intel VROC RAID Key; AOC-VROCINTMOD AOC-VROCSTNMOD AOC-VROCPREMOD; Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only) Intel VROC Standard, RAID 0, 1, 10 Intel VROC Premium, RAID 0, 1, 5, 10; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); SuperDOM; Supermicro SATA DOM Solutions [ Details ]; Network Card(s); AOC-S40G-i2Q AOC-SGP-i2 AOC-SGP-i4 AOC-STG-b4S AOC-STGN-i2S AOC-STGN-i1S AOC-STG-i2T AOC-STG-i2; - - - - - - - -; Standard LP 2-port 40GbE controller, based on Intel Fortville XL710 Standard LP, 2x GbE RJ45, PCI-E x4, Intel i350AM2 Standard LP, 4x GbE RJ45, PCI-E x4, Intel i350 Standard LP, 4x 10GbE SFP+, PCI-E x8, Broadcom BCM57840S Standard LP, 2x 10GbE SFP+, PCI-E x8, Intel 82599ES Standard LP, 1x 10GbE SFP+, PCI-E x8, Intel 82599EN Standard LP, 2x 10GbE RJ45, PCI-E x8, Intel X540 Standard LP, 2x 10GbE CX4, PCI-E x8, Intel 82598EB; Carrier Card(s); AOC-SMG3-2H8M2-B AOC-SMG2-2TM2; 2x Hybrid NVMe/SATA M.2 carrier for BigTwin,HF,RoHS 2x SATA M.2 RAID 1 adapter for BigTwin,HF,RoHS |
| Management - Software | Intel® Node Manager IPMI 2.0 KVM with dedicated LAN SSM , SPM , SUM SuperDoctor® 5 Watch Dog |
| Management - Power Configurations | ACPI / APM Power Management |
| PC Health Monitoring - CPU | Monitors for CPU Cores, Chipset Voltages, Memory. 4+1 Phase-switching voltage regulator |
| Processor - Cores | Up to 28 Cores |
| System Memory - Note | † 2933MHz in two DIMMs per channel can be achieved by using memory purchased from Supermicro †† Cascade Lake only. Contact your Supermicro sales rep for more info. |
| Operating Environment - RoHS | RoHS Compliant |
| Operating Environment - Environmental Spec | Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F) Non-operating Temperature: -40°C to 60°C (-40°F to 140°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) |
| ACDC240V Input Redundant Power Supply | 2600W Redundant Power Supplies with PMBus; 2600W Redundant Power Supplies with PMBus; 2600W Redundant Power Supplies with PMBus; 2600W Redundant Power Supplies with PMBus |
| ACDC240V Input Redundant Power Supply - Total Output Power | 2600W: 208 – 240Vac 2600W: 220 – 240Vdc (for CQC only) |
| ACDC240V Input Redundant Power Supply - DimensionW x H x L | 45 x 40 x 480 mm |
| ACDC240V Input Redundant Power Supply - Input | 208-240Vac/15-12.5A / 50-60Hz 220-240Vdc/13.5-12.5A (CQC only) |
| ACDC240V Input Redundant Power Supply - 12V | Max: 216.6A / Min: 0A |
| ACDC240V Input Redundant Power Supply - Output Type | Gold Finger (4HP+2LP-20S output connector) |
| ACDC240V Input Redundant Power Supply - Certification | Titanium Level [ Test Report ] |
| On-Board Devices - Network | Must bundle with at least one SIOM network card |
| Input Output per Node - LAN | 1 RJ45 Dedicated IPMI LAN port |
| Input Output per Node - USB | 2 USB 3.0 ports (rear) |
| Input Output per Node - Video | 1 VGA port |
| Input Output per Node - DOM | 1 Super DOM (Disk on Module) port |
| Input Output per Node - Others | M.2 and SATA DOM for boot drive only |
| Expansion Slots per Node - PCI-Express | 2 PCI-E 3.0 (x16) Low-profile slots 1 SIOM card support (must bundle with network card) |
| Drive Bays Storage per Node - Hot-swap | 6 Hot-swap 2.5" NVMe drive bays |
| Drive Bays Storage per Node - M2 | 2 M.2 NVMe or SATA (2240/2260/2280) via optional AOC-SMG3-2H8M2-B |
| Product SKUs - SYS-2029BZ-HNR | SuperServer 2029BZ-HNR ( Black ) |
| ACDC240V Input Redundant Power Supply - 12Vsb | Max: 4.5A / Min: 0A |
Отзывы
Загрузка отзывов...
Добавить отзыв
Оплачивайте покупки удобным способом. В интернет-магазине доступно 3 варианта оплаты:
- Наличные при самовывозе или доставке курьером. Специалист свяжется с вами в день доставки, чтобы уточнить время и заранее подготовить сдачу с любой купюры. Вы подписываете товаросопроводительные документы, вносите денежные средства, получаете товар и чек.
- Безналичный расчет при самовывозе или оформлении в интернет-магазине: карты МИР, Visa и MasterCard. Чтобы оплатить покупку, система перенаправит вас на сервер системы ASSIST. Здесь нужно ввести номер карты, срок действия и имя держателя.
- ЮMoney при онлайн-заказе. Для совершения покупки система перенаправит вас на страницу платежного сервиса. Здесь необходимо заполнить форму по инструкции.
Экономьте время на получении заказа. В интернет-магазине доступно 4 варианта доставки:
- Курьерская доставка работает с 9.00 до 19.00. Когда товар поступит на склад, курьерская служба свяжется для уточнения деталей. Специалист предложит выбрать удобное время доставки и уточнит адрес. Осмотрите упаковку на целостность и соответствие указанной комплектации.
- Самовывоз из магазина. Список торговых точек для выбора появится в корзине. Когда заказ поступит на склад, вам придет уведомление. Для получения заказа обратитесь к сотруднику в кассовой зоне и назовите номер.
- Постамат. Когда заказ поступит на точку, на ваш телефон или e-mail придет уникальный код. Заказ нужно оплатить в терминале постамата. Срок хранения — 3 дня.
- Почтовая доставка через почту России. Когда заказ придет в отделение, на ваш адрес придет извещение о посылке. Перед оплатой вы можете оценить состояние коробки: вес, целостность. Вскрывать коробку самостоятельно вы можете только после оплаты заказа. Один заказ может содержать не больше 10 позиций и его стоимость не должна превышать 100 000 р.