SuperServer 2029TP-HC1R
Арт. SYS-2029P-TXRT
Нашли дешевле?
| Motherboard | Super X11DPX-T; Super X11DPX-T; Super X11DPX-T; Super X11DPX-T |
| Processor - CPU | Dual Socket P (LGA 3647) 2nd Gen Intel® Xeon® Scalable Processors and Intel® Xeon® Scalable Processors ‡ , 3 UPI up to 10.4GT/s Support CPU TDP 205W |
| Processor - Note | ‡ BIOS version 3.2 or above is required to support 2nd Gen Intel® Xeon® Scalable processors (codenamed Cascade Lake-R) |
| System Memory - Memory Capacity | 16 DIMM slots Up to 4TB 3DS ECC DDR4-2933MHz † RDIMM/LRDIMM Supports Intel® Optane™ DCPMM †† |
| System Memory - Memory Type | 2933 † /2666/2400/2133MHz ECC DDR4 RDIMM/LRDIMM |
| On-Board Devices - Chipset | Intel® C621 chipset |
| On-Board Devices - SATA | SATA3 (6Gbps) with RAID 0, 1, 5, 10 |
| On-Board Devices - IPMI | Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support |
| On-Board Devices - Network Controllers | Intel® X550-AT2 Dual Port 10GBase-T |
| Input Output - LAN | 2 RJ45 10GBase-T ports 1 RJ45 Dedicated IPMI LAN port |
| Input Output - USB | 2 USB 3.0 ports (rear) 2 USB 2.0 ports (rear) |
| Input Output - Serial Port Header | 1 COM port (rear) |
| PC Health Monitoring - FAN | Fans with tachometer monitoring Status monitor for speed control Pulse Width Modulated (PWM) fan connectors |
| PC Health Monitoring - Temperature | Monitoring for CPU and chassis environment Thermal Control for fan connectors |
| Chassis - Form Factor | 2U Rackmount |
| Chassis - Model | CSE-213XAC-R1K05LP |
| Front Panel - Buttons | Power On/Off button System Reset button |
| Front Panel - LEDs | Power status LED Hard drive activity LED Network activity LEDs System information (overheat/UID) LED Power fail LED |
| Expansion Slots - PCI-Express | 2 PCI-E 3.0 x16 slots 2 PCI-E 3.0 x16 slots (or 4 PCI-E 3.0 x8 by MUX) 4 PCI-E 3.0 x8 slots 1 PCI-E 3.0 x4 (in x8 slot) Support total of 11 Low-profile AOC |
| Drive Bays - Hot-swap | 16 Hot-swap 2.5" drive bays 10 SATA3 ports by default Optional drive support: 16 SAS3 Note: optional storage card is required to support more than 10 drives |
| Backplane | 1 SAS/SATA backplane; 1 SAS/SATA backplane; 1 SAS/SATA backplane; 1 SAS/SATA backplane |
| System Cooling - Fans | 4 Middle fans |
| System BIOS - BIOS Type | AMI UEFI |
| Parts List - Items Included | Part Number; Description; Motherboard / Chassis; MBD-X11DPX-T CSE-213XAC-R1K05LP; Super X11DPX-T Motherboard 2U Chassis; Backplane; BPN-SAS3-213A; 16-port 2U SAS3 12Gbps direct-attached backplane, support up to 16x 2.5-inch SAS3/SATA3 HDD/SSD; Cable 1; CBL-SAST-0508-01; MINI SAS HD-MINI SAS,6G,INT,50CM,SB,30AWG; MCP-260-00042-2N; STD I/O shield for X9/X10/X11 server MB with EMI Gasket & Mylar; Air Shroud; MCP-310-00082-0B; Mylar Air Shroud for SC213X (X11DPX); MCP-450-00003-0N; Plastic M.2 holder kit for X11 MB; Manual; MNL-2081-QRG; 2029P-TXRT Quick Reference Guide; Heatsink / Retention; SNK-P0068PS; 2U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Power Supply; PWS-1K05A-1R; 1U 1000W Redundant Power Supply Titanium, 38X40X360mm length; FAN-0190L4; 80x80x38 mm, 10.5K RPM, Middle Cooling Fan for SC213X Chassis; Part Number; Description; Motherboard / Chassis; MBD-X11DPX-T CSE-213XAC-R1K05LP; Super X11DPX-T Motherboard 2U Chassis; Backplane; BPN-SAS3-213A; 16-port 2U SAS3 12Gbps direct-attached backplane, support up to 16x 2.5-inch SAS3/SATA3 HDD/SSD; Cable 1; CBL-SAST-0508-01; MINI SAS HD-MINI SAS,6G,INT,50CM,SB,30AWG; MCP-260-00042-2N; STD I/O shield for X9/X10/X11 server MB with EMI Gasket & Mylar; Air Shroud; MCP-310-00082-0B; Mylar Air Shroud for SC213X (X11DPX); MCP-450-00003-0N; Plastic M.2 holder kit for X11 MB; Manual; MNL-2081-QRG; 2029P-TXRT Quick Reference Guide; Heatsink / Retention; SNK-P0068PS; 2U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Power Supply; PWS-1K05A-1R; 1U 1000W Redundant Power Supply Titanium, 38X40X360mm length; FAN-0190L4; 80x80x38 mm, 10.5K RPM, Middle Cooling Fan for SC213X Chassis; Part Number; Description; Motherboard / Chassis; MBD-X11DPX-T CSE-213XAC-R1K05LP; Super X11DPX-T Motherboard 2U Chassis; Backplane; BPN-SAS3-213A; 16-port 2U SAS3 12Gbps direct-attached backplane, support up to 16x 2.5-inch SAS3/SATA3 HDD/SSD; Cable 1; CBL-SAST-0508-01; MINI SAS HD-MINI SAS,6G,INT,50CM,SB,30AWG; MCP-260-00042-2N; STD I/O shield for X9/X10/X11 server MB with EMI Gasket & Mylar; Air Shroud; MCP-310-00082-0B; Mylar Air Shroud for SC213X (X11DPX); MCP-450-00003-0N; Plastic M.2 holder kit for X11 MB; Manual; MNL-2081-QRG; 2029P-TXRT Quick Reference Guide; Heatsink / Retention; SNK-P0068PS; 2U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Power Supply; PWS-1K05A-1R; 1U 1000W Redundant Power Supply Titanium, 38X40X360mm length; FAN-0190L4; 80x80x38 mm, 10.5K RPM, Middle Cooling Fan for SC213X Chassis; Part Number; Description; Motherboard / Chassis; MBD-X11DPX-T CSE-213XAC-R1K05LP; Super X11DPX-T Motherboard 2U Chassis; Backplane; BPN-SAS3-213A; 16-port 2U SAS3 12Gbps direct-attached backplane, support up to 16x 2.5-inch SAS3/SATA3 HDD/SSD; Cable 1; CBL-SAST-0508-01; MINI SAS HD-MINI SAS,6G,INT,50CM,SB,30AWG; MCP-260-00042-2N; STD I/O shield for X9/X10/X11 server MB with EMI Gasket & Mylar; Air Shroud; MCP-310-00082-0B; Mylar Air Shroud for SC213X (X11DPX); MCP-450-00003-0N; Plastic M.2 holder kit for X11 MB; Manual; MNL-2081-QRG; 2029P-TXRT Quick Reference Guide; Heatsink / Retention; SNK-P0068PS; 2U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Power Supply; PWS-1K05A-1R; 1U 1000W Redundant Power Supply Titanium, 38X40X360mm length; FAN-0190L4; 80x80x38 mm, 10.5K RPM, Middle Cooling Fan for SC213X Chassis |
| Optional Parts List | Part Number; Description; Cable Management Arm; MCP-290-00073-0N; Supermicro Cable Management Arm for 2U, 3U and 4U chassis; Cable Arm Adapter; MCP-120-82503-0N; Cable arm adapter for SC825,213,829H,847B (MCP-290-00073-0N required); Slim DVD Kit; MCP-220-81502-0N; Slim SATA DVD mounting kit for SC213,219,813,815,818,819,825,828,829,836,842; 5.25" DVD kit; MCP-220-00006-00; 5.25" drive rail set; USB 2.0/COM port tray; MCP-220-00007-01; Black USB2.0 /COM port tray (mount with Slim DVD Kit); USB 3.0/COM port tray; MCP-220-00114-0N; Black 2x USB3.0/COM port tray (mount with Slim DVD Kit); Mobile Rack; CSE-M14TQC & CBL-SAST-0699; Black SAS3/SATA3 Mobile Rack for 4x 2.5 (mount with 5.25" DVD kit); internal mini SAS HD to 4 SATA 12G, 75/75/90/90cm w/75cm SB, S. 30AWG; Storage Control Card and Cable(s); AOC-S3008L-L8e & 2x CBL-SAST-0593; Std LP, 8 internal ports, 12Gb/s per port- Gen3, 122HDD, HBA; Internal Mini-SAS HD to Mini-SAS HD 60cm,30AWG,12Gb/s; Storage Control Card and Cable(s); AOC-S3008L-L8i & 2x CBL-SAST-0593; Std LP, 8 internal ports, 12Gb/s per port- Gen3, 63HDD, RAID 0,1,1E; Internal Mini-SAS HD to Mini-SAS HD 60cm,30AWG,12Gb/s; Storage Control Card and Cable(s); AOC-S3108L-H8iR & 2x CBL-SAST-0593; Std LP, 8 internal ports, 12Gb/s per port- Gen3, 240HDD, RAID 0, 1, 5, 6, 10, 50, 60; Internal Mini-SAS HD to Mini-SAS HD 60cm,30AWG,12Gb/s; CacheVault; BTR-TFM8G-LSICVM02 BKT-BBU-BRACKET-05 MCP-240-00127-0N; Supercap 8GB CV + BKT-BBU-BRACKET-05 or MCP-240-00127-0N x1 Mounting PCIe Card SuperCap tray for 2.5" HDD; P4 GPU kit; MCP-310-00085-0B MCP-310-00086-0B; Mylar Air Shroud(GPU) and air block for SC213X (X11DPX) Mylar Air dummy(GPU) for SC213X; AOC-VROCPREMOD AOC-VROCSTNMOD AOC-VROCINTMOD; Intel VROC Premium, RAID 0, 1, 5, 10 Intel VROC HW key (RSTe) standard upgrade module Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only); TPM security module (optional, not included); AOM-TPM-9670V AOM-TPM-9671V; TPM module (Vertical) TPM 2.0 TPM module (Vertical) TPM 1.2.; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; Cable Management Arm; MCP-290-00073-0N; Supermicro Cable Management Arm for 2U, 3U and 4U chassis; Cable Arm Adapter; MCP-120-82503-0N; Cable arm adapter for SC825,213,829H,847B (MCP-290-00073-0N required); Slim DVD Kit; MCP-220-81502-0N; Slim SATA DVD mounting kit for SC213,219,813,815,818,819,825,828,829,836,842; 5.25" DVD kit; MCP-220-00006-00; 5.25" drive rail set; USB 2.0/COM port tray; MCP-220-00007-01; Black USB2.0 /COM port tray (mount with Slim DVD Kit); USB 3.0/COM port tray; MCP-220-00114-0N; Black 2x USB3.0/COM port tray (mount with Slim DVD Kit); Mobile Rack; CSE-M14TQC & CBL-SAST-0699; Black SAS3/SATA3 Mobile Rack for 4x 2.5 (mount with 5.25" DVD kit); internal mini SAS HD to 4 SATA 12G, 75/75/90/90cm w/75cm SB, S. 30AWG; Storage Control Card and Cable(s); AOC-S3008L-L8e & 2x CBL-SAST-0593; Std LP, 8 internal ports, 12Gb/s per port- Gen3, 122HDD, HBA; Internal Mini-SAS HD to Mini-SAS HD 60cm,30AWG,12Gb/s; Storage Control Card and Cable(s); AOC-S3008L-L8i & 2x CBL-SAST-0593; Std LP, 8 internal ports, 12Gb/s per port- Gen3, 63HDD, RAID 0,1,1E; Internal Mini-SAS HD to Mini-SAS HD 60cm,30AWG,12Gb/s; Storage Control Card and Cable(s); AOC-S3108L-H8iR & 2x CBL-SAST-0593; Std LP, 8 internal ports, 12Gb/s per port- Gen3, 240HDD, RAID 0, 1, 5, 6, 10, 50, 60; Internal Mini-SAS HD to Mini-SAS HD 60cm,30AWG,12Gb/s; CacheVault; BTR-TFM8G-LSICVM02 BKT-BBU-BRACKET-05 MCP-240-00127-0N; Supercap 8GB CV + BKT-BBU-BRACKET-05 or MCP-240-00127-0N x1 Mounting PCIe Card SuperCap tray for 2.5" HDD; P4 GPU kit; MCP-310-00085-0B MCP-310-00086-0B; Mylar Air Shroud(GPU) and air block for SC213X (X11DPX) Mylar Air dummy(GPU) for SC213X; AOC-VROCPREMOD AOC-VROCSTNMOD AOC-VROCINTMOD; Intel VROC Premium, RAID 0, 1, 5, 10 Intel VROC HW key (RSTe) standard upgrade module Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only); TPM security module (optional, not included); AOM-TPM-9670V AOM-TPM-9671V; TPM module (Vertical) TPM 2.0 TPM module (Vertical) TPM 1.2.; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; Cable Management Arm; MCP-290-00073-0N; Supermicro Cable Management Arm for 2U, 3U and 4U chassis; Cable Arm Adapter; MCP-120-82503-0N; Cable arm adapter for SC825,213,829H,847B (MCP-290-00073-0N required); Slim DVD Kit; MCP-220-81502-0N; Slim SATA DVD mounting kit for SC213,219,813,815,818,819,825,828,829,836,842; 5.25" DVD kit; MCP-220-00006-00; 5.25" drive rail set; USB 2.0/COM port tray; MCP-220-00007-01; Black USB2.0 /COM port tray (mount with Slim DVD Kit); USB 3.0/COM port tray; MCP-220-00114-0N; Black 2x USB3.0/COM port tray (mount with Slim DVD Kit); Mobile Rack; CSE-M14TQC & CBL-SAST-0699; Black SAS3/SATA3 Mobile Rack for 4x 2.5 (mount with 5.25" DVD kit); internal mini SAS HD to 4 SATA 12G, 75/75/90/90cm w/75cm SB, S. 30AWG; Storage Control Card and Cable(s); AOC-S3008L-L8e & 2x CBL-SAST-0593; Std LP, 8 internal ports, 12Gb/s per port- Gen3, 122HDD, HBA; Internal Mini-SAS HD to Mini-SAS HD 60cm,30AWG,12Gb/s; Storage Control Card and Cable(s); AOC-S3008L-L8i & 2x CBL-SAST-0593; Std LP, 8 internal ports, 12Gb/s per port- Gen3, 63HDD, RAID 0,1,1E; Internal Mini-SAS HD to Mini-SAS HD 60cm,30AWG,12Gb/s; Storage Control Card and Cable(s); AOC-S3108L-H8iR & 2x CBL-SAST-0593; Std LP, 8 internal ports, 12Gb/s per port- Gen3, 240HDD, RAID 0, 1, 5, 6, 10, 50, 60; Internal Mini-SAS HD to Mini-SAS HD 60cm,30AWG,12Gb/s; CacheVault; BTR-TFM8G-LSICVM02 BKT-BBU-BRACKET-05 MCP-240-00127-0N; Supercap 8GB CV + BKT-BBU-BRACKET-05 or MCP-240-00127-0N x1 Mounting PCIe Card SuperCap tray for 2.5" HDD; P4 GPU kit; MCP-310-00085-0B MCP-310-00086-0B; Mylar Air Shroud(GPU) and air block for SC213X (X11DPX) Mylar Air dummy(GPU) for SC213X; AOC-VROCPREMOD AOC-VROCSTNMOD AOC-VROCINTMOD; Intel VROC Premium, RAID 0, 1, 5, 10 Intel VROC HW key (RSTe) standard upgrade module Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only); TPM security module (optional, not included); AOM-TPM-9670V AOM-TPM-9671V; TPM module (Vertical) TPM 2.0 TPM module (Vertical) TPM 1.2.; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; Cable Management Arm; MCP-290-00073-0N; Supermicro Cable Management Arm for 2U, 3U and 4U chassis; Cable Arm Adapter; MCP-120-82503-0N; Cable arm adapter for SC825,213,829H,847B (MCP-290-00073-0N required); Slim DVD Kit; MCP-220-81502-0N; Slim SATA DVD mounting kit for SC213,219,813,815,818,819,825,828,829,836,842; 5.25" DVD kit; MCP-220-00006-00; 5.25" drive rail set; USB 2.0/COM port tray; MCP-220-00007-01; Black USB2.0 /COM port tray (mount with Slim DVD Kit); USB 3.0/COM port tray; MCP-220-00114-0N; Black 2x USB3.0/COM port tray (mount with Slim DVD Kit); Mobile Rack; CSE-M14TQC & CBL-SAST-0699; Black SAS3/SATA3 Mobile Rack for 4x 2.5 (mount with 5.25" DVD kit); internal mini SAS HD to 4 SATA 12G, 75/75/90/90cm w/75cm SB, S. 30AWG; Storage Control Card and Cable(s); AOC-S3008L-L8e & 2x CBL-SAST-0593; Std LP, 8 internal ports, 12Gb/s per port- Gen3, 122HDD, HBA; Internal Mini-SAS HD to Mini-SAS HD 60cm,30AWG,12Gb/s; Storage Control Card and Cable(s); AOC-S3008L-L8i & 2x CBL-SAST-0593; Std LP, 8 internal ports, 12Gb/s per port- Gen3, 63HDD, RAID 0,1,1E; Internal Mini-SAS HD to Mini-SAS HD 60cm,30AWG,12Gb/s; Storage Control Card and Cable(s); AOC-S3108L-H8iR & 2x CBL-SAST-0593; Std LP, 8 internal ports, 12Gb/s per port- Gen3, 240HDD, RAID 0, 1, 5, 6, 10, 50, 60; Internal Mini-SAS HD to Mini-SAS HD 60cm,30AWG,12Gb/s; CacheVault; BTR-TFM8G-LSICVM02 BKT-BBU-BRACKET-05 MCP-240-00127-0N; Supercap 8GB CV + BKT-BBU-BRACKET-05 or MCP-240-00127-0N x1 Mounting PCIe Card SuperCap tray for 2.5" HDD; P4 GPU kit; MCP-310-00085-0B MCP-310-00086-0B; Mylar Air Shroud(GPU) and air block for SC213X (X11DPX) Mylar Air dummy(GPU) for SC213X; AOC-VROCPREMOD AOC-VROCSTNMOD AOC-VROCINTMOD; Intel VROC Premium, RAID 0, 1, 5, 10 Intel VROC HW key (RSTe) standard upgrade module Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only); TPM security module (optional, not included); AOM-TPM-9670V AOM-TPM-9671V; TPM module (Vertical) TPM 2.0 TPM module (Vertical) TPM 1.2.; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license) |
| Management - Software | Intel® Node Manager IPMI 2.0 KVM with dedicated LAN NMI SSM , SPM , SUM SuperDoctor® 5 |
| Management - Power Configurations | ACPI Power Management |
| Input Output - Serial ATA | 8 SATA3 (6Gbps) ports |
| Input Output - DOM | 2 Super DOM (Disk on Module) ports |
| Input Output - TPM | 1 TPM 2.0 Header |
| On-Board Devices - Graphics | ASPEED AST2500 BMC |
| Dimensions - Width | 17.2" (437mm) |
| Dimensions - Height | 3.5" (89mm) |
| Dimensions - Depth | 25.6" (650mm) |
| Dimensions - Weight | Net Weight: 36 lbs (16.4 kg) Gross Weight: 72 lbs (32.7 kg) |
| Dimensions - Available Colors | Black |
| PC Health Monitoring - CPU | Monitors for CPU Cores, Chipset Voltages, Memory. 4+1 Phase-switching voltage regulator |
| Input Output - VGA | 1 VGA port |
| Processor - Cores | Up to 28 Cores |
| System Memory - Note | † 2933MHz in two DIMMs per channel can be achieved by using memory purchased from Supermicro †† Cascade Lake only. Contact your Supermicro sales rep for more info. |
| Operating Environment - RoHS | RoHS Compliant |
| Operating Environment - Environmental Spec | Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F) Non-operating Temperature: -40°C to 60°C (-40°F to 140°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) |
| Product SKUs - SYS-2029P-TXRT | SuperServer 2029P-TXRT ( Black ) |
| Dimensions - Package | 14.8" (H) x 27" (W) x 37.3" (D) |
| Peripheral Bay - Peripheral | 1 slim DVD-ROM drive |
| PowerStick Power Supply | 1000W 1U Redundant Power Supplies with PMBus; 1000W 1U Redundant Power Supplies with PMBus; 1000W 1U Redundant Power Supplies with PMBus; 1000W 1U Redundant Power Supplies with PMBus |
| PowerStick Power Supply - Total Output Power | 800W: 100 – 127Vac 1000W: 200 – 240Vac |
| PowerStick Power Supply - DimensionW x H x L | 38 x 40 x 360 mm |
| PowerStick Power Supply - Input | 100-127Vac / 9-7.5A / 50-60Hz 200-240Vac / 6-5A / 50-60Hz |
| PowerStick Power Supply - 12V | Max: 66.7A / Min: 0A (100-127Vac) Max: 83A / Min: 0A (200-240Vac) |
| PowerStick Power Supply - 5Vsb | Max: 4A / Min: 0A |
| PowerStick Power Supply - Output Type | Gold Finger Connector (16 Power Pin, 14 Signal Pin) |
| PowerStick Power Supply - Certification | Titanium Level [ Test Report ] |
Отзывы
Загрузка отзывов...
Добавить отзыв
Оплачивайте покупки удобным способом. В интернет-магазине доступно 3 варианта оплаты:
- Наличные при самовывозе или доставке курьером. Специалист свяжется с вами в день доставки, чтобы уточнить время и заранее подготовить сдачу с любой купюры. Вы подписываете товаросопроводительные документы, вносите денежные средства, получаете товар и чек.
- Безналичный расчет при самовывозе или оформлении в интернет-магазине: карты МИР, Visa и MasterCard. Чтобы оплатить покупку, система перенаправит вас на сервер системы ASSIST. Здесь нужно ввести номер карты, срок действия и имя держателя.
- ЮMoney при онлайн-заказе. Для совершения покупки система перенаправит вас на страницу платежного сервиса. Здесь необходимо заполнить форму по инструкции.
Экономьте время на получении заказа. В интернет-магазине доступно 4 варианта доставки:
- Курьерская доставка работает с 9.00 до 19.00. Когда товар поступит на склад, курьерская служба свяжется для уточнения деталей. Специалист предложит выбрать удобное время доставки и уточнит адрес. Осмотрите упаковку на целостность и соответствие указанной комплектации.
- Самовывоз из магазина. Список торговых точек для выбора появится в корзине. Когда заказ поступит на склад, вам придет уведомление. Для получения заказа обратитесь к сотруднику в кассовой зоне и назовите номер.
- Постамат. Когда заказ поступит на точку, на ваш телефон или e-mail придет уникальный код. Заказ нужно оплатить в терминале постамата. Срок хранения — 3 дня.
- Почтовая доставка через почту России. Когда заказ придет в отделение, на ваш адрес придет извещение о посылке. Перед оплатой вы можете оценить состояние коробки: вес, целостность. Вскрывать коробку самостоятельно вы можете только после оплаты заказа. Один заказ может содержать не больше 10 позиций и его стоимость не должна превышать 100 000 р.
