SuperServer 2029U-E1CR25
Арт. SYS-2029TP-HC1R
Нашли дешевле?
| PC Health Monitoring - FAN | Fans with tachometer monitoring Status monitor for speed control Pulse Width Modulated (PWM) fan connectors |
| PC Health Monitoring - Temperature | Monitoring for CPU and chassis environment Thermal Control for fan connectors |
| Chassis - Form Factor | 2U Rackmount |
| Chassis - Model | CSE-217HQ+-R2K20BP3 |
| Dimensions and Weight - Height | 3.47" (88mm) |
| Dimensions and Weight - Width | 17.25" (438mm) |
| Dimensions and Weight - Depth | 28.5" (724mm) |
| Dimensions and Weight - Weight | Gross Weight: 90 lbs (40.9kg) Net Weight: 72 lbs (32.7 kg) |
| Dimensions and Weight - Available Colors | Black |
| Front Panel - Buttons | Power On/Off button UID button |
| Front Panel - LEDs | Power status LED HDD activity LED Network activity LEDs Universal Information (UID) LED |
| System Cooling - Fans | 4 Heavy duty 8cm PWM fans with optimal fan speed control |
| Power Supply | 2200W Redundant Power Supplies with PMBus; 2200W Redundant Power Supplies with PMBus; 2200W Redundant Power Supplies with PMBus; 2200W Redundant Power Supplies with PMBus |
| Power Supply - 12V | Max: 100A / Min: 0A (100-127Vac) Max: 150A / Min: 0A (200-220Vac) Max: 165A / Min: 0A (220-230Vac) Max: 174.17A / Min: 0A (230-240Vac) Max: 183.3A / Min: 0A (220-240Vac) |
| Power Supply - Certification | Titanium Level [ Test Report ] |
| System BIOS - BIOS Type | AMI 32MB SPI Flash ROM |
| Parts List - Items Included | Part Number; Description; Motherboard / Chassis; MBD-X11DPT-PS CSE-217HQ+-R2K20BP3; Super X11DPT-PS Motherboards 2U Chassis; Backplane; BPN-ADP-S3108L-H6IRP; LSI 3108, SAS 12Gbps (x6 internal); Broadcom 3108 2GB cache; Backplane; BPN-SAS3-217HQ2; 2U 24-Port 4-Node Backplane Supports 6x 2.5"; Cable 1; CBL-PWCD-0578; PWCD,US,IEC60320 C14 TO C13,3FT,14AWG; Air Shroud; MCP-310-21716-0B; Twinpro X11 air shroud; Riser Card; RSC-P-6; RSC-P-6 (1U LHS TwinPro RSC with 1 PCI-Ex16),RoHS; Riser Card; RSC-R1UTP-E16R; 1U RHS TwinPro Riser card with one PCI-E x16 slot; Heatsink / Retention; SNK-P0067PS; 1U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Heatsink / Retention; SNK-P0067PSM; 1U Passive CPU Heat Sink with a 26-mm Wide Middle Air Channel for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Power Supply; PWS-2K20A-1R; 1U 2200W Redundant, Titanium, 76(W) X 40(H) X 336(L) mm; Part Number; Description; Motherboard / Chassis; MBD-X11DPT-PS CSE-217HQ+-R2K20BP3; Super X11DPT-PS Motherboards 2U Chassis; Backplane; BPN-ADP-S3108L-H6IRP; LSI 3108, SAS 12Gbps (x6 internal); Broadcom 3108 2GB cache; Backplane; BPN-SAS3-217HQ2; 2U 24-Port 4-Node Backplane Supports 6x 2.5"; Cable 1; CBL-PWCD-0578; PWCD,US,IEC60320 C14 TO C13,3FT,14AWG; Air Shroud; MCP-310-21716-0B; Twinpro X11 air shroud; Riser Card; RSC-P-6; RSC-P-6 (1U LHS TwinPro RSC with 1 PCI-Ex16),RoHS; Riser Card; RSC-R1UTP-E16R; 1U RHS TwinPro Riser card with one PCI-E x16 slot; Heatsink / Retention; SNK-P0067PS; 1U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Heatsink / Retention; SNK-P0067PSM; 1U Passive CPU Heat Sink with a 26-mm Wide Middle Air Channel for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Power Supply; PWS-2K20A-1R; 1U 2200W Redundant, Titanium, 76(W) X 40(H) X 336(L) mm; Part Number; Description; Motherboard / Chassis; MBD-X11DPT-PS CSE-217HQ+-R2K20BP3; Super X11DPT-PS Motherboards 2U Chassis; Backplane; BPN-ADP-S3108L-H6IRP; LSI 3108, SAS 12Gbps (x6 internal); Broadcom 3108 2GB cache; Backplane; BPN-SAS3-217HQ2; 2U 24-Port 4-Node Backplane Supports 6x 2.5"; Cable 1; CBL-PWCD-0578; PWCD,US,IEC60320 C14 TO C13,3FT,14AWG; Air Shroud; MCP-310-21716-0B; Twinpro X11 air shroud; Riser Card; RSC-P-6; RSC-P-6 (1U LHS TwinPro RSC with 1 PCI-Ex16),RoHS; Riser Card; RSC-R1UTP-E16R; 1U RHS TwinPro Riser card with one PCI-E x16 slot; Heatsink / Retention; SNK-P0067PS; 1U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Heatsink / Retention; SNK-P0067PSM; 1U Passive CPU Heat Sink with a 26-mm Wide Middle Air Channel for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Power Supply; PWS-2K20A-1R; 1U 2200W Redundant, Titanium, 76(W) X 40(H) X 336(L) mm; Part Number; Description; Motherboard / Chassis; MBD-X11DPT-PS CSE-217HQ+-R2K20BP3; Super X11DPT-PS Motherboards 2U Chassis; Backplane; BPN-ADP-S3108L-H6IRP; LSI 3108, SAS 12Gbps (x6 internal); Broadcom 3108 2GB cache; Backplane; BPN-SAS3-217HQ2; 2U 24-Port 4-Node Backplane Supports 6x 2.5"; Cable 1; CBL-PWCD-0578; PWCD,US,IEC60320 C14 TO C13,3FT,14AWG; Air Shroud; MCP-310-21716-0B; Twinpro X11 air shroud; Riser Card; RSC-P-6; RSC-P-6 (1U LHS TwinPro RSC with 1 PCI-Ex16),RoHS; Riser Card; RSC-R1UTP-E16R; 1U RHS TwinPro Riser card with one PCI-E x16 slot; Heatsink / Retention; SNK-P0067PS; 1U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Heatsink / Retention; SNK-P0067PSM; 1U Passive CPU Heat Sink with a 26-mm Wide Middle Air Channel for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Power Supply; PWS-2K20A-1R; 1U 2200W Redundant, Titanium, 76(W) X 40(H) X 336(L) mm |
| Optional Parts List | Part Number; Description; TPM security module (optional, not included); AOM-TPM-9670V; SPI capable TPM 2.0 with Infineon 9670 controller with vertical form factor; TPM security module (optional, not included); AOM-TPM-9671V; SPI capable TPM 1.2 with Infineon 9670 controller with vertical form factor; SuperCap Kit; BTR-CV3108-TP2; Broadcom 3108 CacheVault kit for TwinPro; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; TPM security module (optional, not included); AOM-TPM-9670V; SPI capable TPM 2.0 with Infineon 9670 controller with vertical form factor; TPM security module (optional, not included); AOM-TPM-9671V; SPI capable TPM 1.2 with Infineon 9670 controller with vertical form factor; SuperCap Kit; BTR-CV3108-TP2; Broadcom 3108 CacheVault kit for TwinPro; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; TPM security module (optional, not included); AOM-TPM-9670V; SPI capable TPM 2.0 with Infineon 9670 controller with vertical form factor; TPM security module (optional, not included); AOM-TPM-9671V; SPI capable TPM 1.2 with Infineon 9670 controller with vertical form factor; SuperCap Kit; BTR-CV3108-TP2; Broadcom 3108 CacheVault kit for TwinPro; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; TPM security module (optional, not included); AOM-TPM-9670V; SPI capable TPM 2.0 with Infineon 9670 controller with vertical form factor; TPM security module (optional, not included); AOM-TPM-9671V; SPI capable TPM 1.2 with Infineon 9670 controller with vertical form factor; SuperCap Kit; BTR-CV3108-TP2; Broadcom 3108 CacheVault kit for TwinPro; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license) |
| Management - Software | Intel® Node Manager IPMI 2.0 KVM with dedicated LAN NMI SSM , SPM , SUM SuperDoctor® 5 Watchdog |
| Management - Power Configurations | ACPI Power Management |
| Power Supply - 5VSB | Max: 1A / Min: 0A |
| PC Health Monitoring - CPU | Monitors for CPU Cores, Chipset Voltages, Memory. 5+1 Phase-switching voltage regulator |
| Operating Environment - RoHS | RoHS Compliant |
| Operating Environment - Environmental Spec | Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F) Non-operating Temperature: -40°C to 60°C (-40°F to 140°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) |
| Power Supply - DimensionW x H x L | 76 x 40 x 336 mm |
| Power Supply - Output Type | Backplanes (gold finger) |
| Processor per Node - CPU | Dual Socket P (LGA 3647) 2nd Gen Intel® Xeon® Scalable Processors and Intel® Xeon® Scalable Processors ‡ , Dual UPI up to 10.4GT/s Support CPU TDP 70-165W * |
| Processor per Node - Cores | Up to 28 Cores |
| Processor per Node - Note | ‡ BIOS version 3.2 or above is required to support 2nd Gen Intel® Xeon® Scalable processors (codenamed Cascade Lake-R) |
| System Memory per Node - Memory Capacity | 16 DIMM slots Up to 4TB 3DS ECC DDR4-2933MHz † RDIMM/LRDIMM Supports Intel® Optane™ DCPMM †† |
| System Memory per Node - Memory Type | 2933 † /2666/2400/2133MHz ECC DDR4 RDIMM/LRDIMM |
| System Memory per Node - Note | † 2933MHz in two DIMMs per channel can be achieved by using memory purchased from Supermicro †† Cascade Lake only. Contact your Supermicro sales rep for more info. |
| Input Output per Node - LAN | 1 RJ45 Dedicated IPMI LAN port |
| Input Output per Node - USB | 2 USB 3.0 ports (rear) |
| Input Output per Node - Others | 2 SuperDOM support on the motherboard. SuperDOM is for OS boot. |
| Expansion Slots per Node - PCI-Express | 2 PCI-E 3.0 x16 Low-profile slots 1 SIOM card support Note: Barebones and Complete System must bundle with Network Card Note: With only one CPU installed, SXB2 M.2 and SXB4 riser card slots not function. This SKU does not support AOC-SMG3-2H8M2 M.2 carrier. |
| Drive Bays per Node - Hot-swap | 6 Hot-swap 2.5" SAS/SATA HDD trays |
| Power Supply - Total Output Power and Input | 1200W with Input 100-127Vac 1800W with Input 200-220Vac 1980W with Input 220-230Vac 2090W with Input 230-240Vac 2200W with Input 220-240Vac (for UL/cUL use only) 2090W with Input 230-240Vdc (for CCC only) |
| Power Supply - AC Input Frequency | 50-60Hz |
| Motherboard Four per System | Super X11DPT-PS; Super X11DPT-PS; Super X11DPT-PS; Super X11DPT-PS |
| On-Board Devices per Node - Chipset | Intel® C621 chipset |
| On-Board Devices per Node - Network Controllers | Barebones and Complete System must have at least one SIOM or network card installed per node |
| On-Board Devices per Node - IPMI | Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support |
| On-Board Devices per Node - Graphics | ASPEED AST2500 BMC |
| Input Output per Node - VGA | 1 VGA port |
| Input Output per Node - Serial Port Header | 1 Fast UART 16550 port / 1 Header (internal) |
| PC Health Monitoring - Omni-Path Fabric CPUs | Do not support |
| Product SKUs - SYS-2029TP-HC1R | SuperServer 2029TP-HC1R ( Black ) |
| On-Board Devices per Node - SAS | Broadcom 3108 SAS3 (12Gbps) controller, 2GB cache; RAID 0, 1, 5, 6, 10, 50, 60 support Optional SuperCap |
| Input Output per Node - SAS | 6 SAS3 (12Gbps) ports |
Отзывы
Загрузка отзывов...
Добавить отзыв
Оплачивайте покупки удобным способом. В интернет-магазине доступно 3 варианта оплаты:
- Наличные при самовывозе или доставке курьером. Специалист свяжется с вами в день доставки, чтобы уточнить время и заранее подготовить сдачу с любой купюры. Вы подписываете товаросопроводительные документы, вносите денежные средства, получаете товар и чек.
- Безналичный расчет при самовывозе или оформлении в интернет-магазине: карты МИР, Visa и MasterCard. Чтобы оплатить покупку, система перенаправит вас на сервер системы ASSIST. Здесь нужно ввести номер карты, срок действия и имя держателя.
- ЮMoney при онлайн-заказе. Для совершения покупки система перенаправит вас на страницу платежного сервиса. Здесь необходимо заполнить форму по инструкции.
Экономьте время на получении заказа. В интернет-магазине доступно 4 варианта доставки:
- Курьерская доставка работает с 9.00 до 19.00. Когда товар поступит на склад, курьерская служба свяжется для уточнения деталей. Специалист предложит выбрать удобное время доставки и уточнит адрес. Осмотрите упаковку на целостность и соответствие указанной комплектации.
- Самовывоз из магазина. Список торговых точек для выбора появится в корзине. Когда заказ поступит на склад, вам придет уведомление. Для получения заказа обратитесь к сотруднику в кассовой зоне и назовите номер.
- Постамат. Когда заказ поступит на точку, на ваш телефон или e-mail придет уникальный код. Заказ нужно оплатить в терминале постамата. Срок хранения — 3 дня.
- Почтовая доставка через почту России. Когда заказ придет в отделение, на ваш адрес придет извещение о посылке. Перед оплатой вы можете оценить состояние коробки: вес, целостность. Вскрывать коробку самостоятельно вы можете только после оплаты заказа. Один заказ может содержать не больше 10 позиций и его стоимость не должна превышать 100 000 р.