| Motherboard | Super X11DPU; Super X11DPU; Super X11DPU; Super X11DPU |
| Processor - CPU | Dual Socket P (LGA 3647) 2nd Gen Intel® Xeon® Scalable Processors and Intel® Xeon® Scalable Processors ‡ , Dual UPI up to 10.4GT/s Support CPU TDP 70-205W |
| Processor - Note | ‡ BIOS version 3.2 or above is required to support 2nd Gen Intel® Xeon® Scalable processors (codenamed Cascade Lake-R) |
| System Memory - Memory Capacity | 24 DIMM slots Up to 6TB 3DS ECC DDR4-2933MHz † RDIMM/LRDIMM Supports Intel® Optane™ DCPMM †† |
| System Memory - Memory Type | 2933 † /2666/2400/2133MHz ECC DDR4 RDIMM/LRDIMM 2666 ECC DDR4 NVDIMM |
| On-Board Devices - Chipset | Intel® C621 chipset |
| On-Board Devices - SATA | SATA3 (6Gbps); RAID 0, 1, 5, 10 |
| On-Board Devices - IPMI | Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support |
| Input Output - SATA | 14 SATA3 (6Gbps) ports |
| Input Output - LAN | 2 10G SFP+ ports 1 RJ45 Dedicated IPMI LAN port |
| Input Output - USB | 5 USB 3.0 ports (2 rear, 2 onboard header, 1 Type A) |
| Input Output - Video | 1 VGA Connector |
| PC Health Monitoring - FAN | Fans with tachometer monitoring Status monitor for speed control Pulse Width Modulated (PWM) fan connectors |
| PC Health Monitoring - Temperature | Monitoring for CPU and chassis environment Thermal Control for fan connectors |
| Chassis - Form Factor | 2U Rackmount |
| Chassis - Model | CSE-219U2TS-R1K02P-T |
| Dimensions and Weight - Height | 3.5" (89mm) |
| Dimensions and Weight - Width | 17.2" (437mm) |
| Dimensions and Weight - Depth | 27.76" (705.3mm) |
| Dimensions and Weight - Weight | Net Weight: 36 lbs (16.4 kg) Gross Weight: 72 lbs (32.7 kg) |
| Dimensions and Weight - Available Colors | Black |
| Front Panel - Buttons | Power On/Off button System Reset button |
| Front Panel - LEDs | Power status LED HDD activity LED Network activity LEDs System information (overheat/UID) LED |
| Expansion Slots - PCI-Express | 1 PCI-E 3.0 x16 (FH, 10.5" L) 5 PCI-E 3.0 x8 (FH, 10.5" L) 1 PCI-E 3.0 x8 (LP) 1 PCI-E 3.0 x8 (internal LP) (Both CPUs need to be installed for full access to PCI-E slots and onboard controllers. See manual block diagram and AOC Support for details.) |
| Backplane | 2U SAS/SATA backplane; 2U SAS/SATA backplane; 2U SAS/SATA backplane; 2U SAS/SATA backplane |
| System Cooling - Fans | 4 Heavy duty 8cm PWM fans |
| Power Supply | 1000W Redundant Power Supplies with PMBus; 1000W Redundant Power Supplies with PMBus; 1000W Redundant Power Supplies with PMBus; 1000W Redundant Power Supplies with PMBus |
| Power Supply - 12V | Max: 66.7A / Min: 0A (100-127Vac) Max: 83A / Min: 0A (200-240Vac) Max: 83A / Min: 0A (200-240Vdc) |
| Power Supply - Certification | Titanium Level [ Test Report ] |
| System BIOS - BIOS Type | AMI 32Mb SPI Flash ROM |
| Parts List - Items Included | Part Number; Description; Motherboard / Chassis; MBD-X11DPU CSE-219U2TS-R1K02P-T; Super X11DPU Motherboard 2U Chassis; Add-on Card / Module; AOC-2UR68-I2XS; 2U Ultra Riser based on Intel 82599ES controller with 2 10Gb SFP+ ports, 1 internal PCI-E x8 3.0 slot, 1 PCI-E x16 3.0, and I PCI-E x8 3.0 (in x16 slot); Backplane; BPN-SAS3-216A-N4; 24-port 2U SAS3 12Gbps hybrid backplane, support up to 20x 2.5-inch SAS3/SATA3 HDD/SSD and 4x SAS3/SATA3/NVMe Storage Devices; Cable 1; CBL-PWEX-0673; 8 pin female to 2x big 4 pin female power, 65/70CM, 18AWG,RoHS/REACH; Cable 2; CBL-SAST-0591; MINI SAS HD-4 SATA,6G,INT,RF,Cross Over,75CM,75CM SB,30AWG; Cable 3; CBL-SAST-0655; MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,47CM,SB,30AWG; Cable 4; CBL-SAST-0656; MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,39CM,SB,30AWG; Cable 5; CBL-SAST-0657; MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,55CM,SB,30AWG; Air Shroud; MCP-310-82921-0N; Plastic air shroud for SC829U, 219U (X11 24DIMM, left side); Air Shroud; MCP-310-82922-0N; Plastic air shroud for SC829U, 219U (X11 24DIMM, right side); Riser Card; RSC-R1UW-E8R; 1U RHS WIO Riser card with one PCI-E x8 slot; Riser Card; RSC-R2UW-4E8; 2U LHS WIO Riser card with four PCI-E x4 slots; Heatsink / Retention; SNK-P0068PS; 2U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; * Power Supply; PWS-1K02A-1R; 1U 1000W Redundant Power Supply 73.5mm width Titanium Level,RoHS/REACH; * Cable 6; CBL-0088L; 4 PIN MIDDLE FAN POWER CABLE (PWM). 27cm, 24AWG; * Cable 7; CBL-0160L; NEMA5-15P to C13 US power cord 16AWG 6ft, PBF (default for high watt); * Cable 8; CBL-0318L; CBL,FRONT CNTL,16 TO 16 PIN,RA,RND TUBE,24CM,28AWG; * FAN 1; FAN-0118L4; 80 x 80 x 38 mm, 9.5K RPM, 4-pin PWM Fan, Hot; * Drive Tray(s); MCP-220-00147-0B; Black gen-3 hot-swap 2.5"; Tool-less HDD tray (clip design); * Rail Set; MCP-290-00057-0N; Rail set, quick/quick, default for 4U 17.2"; W; * Rail Set; MCP-290-00060-0N; Threaded rail adapter default for round hole rack; * Air Shroud; MCP-310-81905-0B; Plastic air shroud for SC819U, 119U, 829U, 219U (PWS),RoHS/REACH; * Front Panel; Front panel adaptor board (TB826) forSC826,213,216,219; * Rail Set; MCP-290-00115-0N; Inner rail, quick-release type; * Rail Set; MCP-290-00117-0N; Outer rail, quick-release type; Part Number; Description; Motherboard / Chassis; MBD-X11DPU CSE-219U2TS-R1K02P-T; Super X11DPU Motherboard 2U Chassis; Add-on Card / Module; AOC-2UR68-I2XS; 2U Ultra Riser based on Intel 82599ES controller with 2 10Gb SFP+ ports, 1 internal PCI-E x8 3.0 slot, 1 PCI-E x16 3.0, and I PCI-E x8 3.0 (in x16 slot); Backplane; BPN-SAS3-216A-N4; 24-port 2U SAS3 12Gbps hybrid backplane, support up to 20x 2.5-inch SAS3/SATA3 HDD/SSD and 4x SAS3/SATA3/NVMe Storage Devices; Cable 1; CBL-PWEX-0673; 8 pin female to 2x big 4 pin female power, 65/70CM, 18AWG,RoHS/REACH; Cable 2; CBL-SAST-0591; MINI SAS HD-4 SATA,6G,INT,RF,Cross Over,75CM,75CM SB,30AWG; Cable 3; CBL-SAST-0655; MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,47CM,SB,30AWG; Cable 4; CBL-SAST-0656; MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,39CM,SB,30AWG; Cable 5; CBL-SAST-0657; MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,55CM,SB,30AWG; Air Shroud; MCP-310-82921-0N; Plastic air shroud for SC829U, 219U (X11 24DIMM, left side); Air Shroud; MCP-310-82922-0N; Plastic air shroud for SC829U, 219U (X11 24DIMM, right side); Riser Card; RSC-R1UW-E8R; 1U RHS WIO Riser card with one PCI-E x8 slot; Riser Card; RSC-R2UW-4E8; 2U LHS WIO Riser card with four PCI-E x4 slots; Heatsink / Retention; SNK-P0068PS; 2U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; * Power Supply; PWS-1K02A-1R; 1U 1000W Redundant Power Supply 73.5mm width Titanium Level,RoHS/REACH; * Cable 6; CBL-0088L; 4 PIN MIDDLE FAN POWER CABLE (PWM). 27cm, 24AWG; * Cable 7; CBL-0160L; NEMA5-15P to C13 US power cord 16AWG 6ft, PBF (default for high watt); * Cable 8; CBL-0318L; CBL,FRONT CNTL,16 TO 16 PIN,RA,RND TUBE,24CM,28AWG; * FAN 1; FAN-0118L4; 80 x 80 x 38 mm, 9.5K RPM, 4-pin PWM Fan, Hot; * Drive Tray(s); MCP-220-00147-0B; Black gen-3 hot-swap 2.5"; Tool-less HDD tray (clip design); * Rail Set; MCP-290-00057-0N; Rail set, quick/quick, default for 4U 17.2"; W; * Rail Set; MCP-290-00060-0N; Threaded rail adapter default for round hole rack; * Air Shroud; MCP-310-81905-0B; Plastic air shroud for SC819U, 119U, 829U, 219U (PWS),RoHS/REACH; * Front Panel; Front panel adaptor board (TB826) forSC826,213,216,219; * Rail Set; MCP-290-00115-0N; Inner rail, quick-release type; * Rail Set; MCP-290-00117-0N; Outer rail, quick-release type; Part Number; Description; Motherboard / Chassis; MBD-X11DPU CSE-219U2TS-R1K02P-T; Super X11DPU Motherboard 2U Chassis; Add-on Card / Module; AOC-2UR68-I2XS; 2U Ultra Riser based on Intel 82599ES controller with 2 10Gb SFP+ ports, 1 internal PCI-E x8 3.0 slot, 1 PCI-E x16 3.0, and I PCI-E x8 3.0 (in x16 slot); Backplane; BPN-SAS3-216A-N4; 24-port 2U SAS3 12Gbps hybrid backplane, support up to 20x 2.5-inch SAS3/SATA3 HDD/SSD and 4x SAS3/SATA3/NVMe Storage Devices; Cable 1; CBL-PWEX-0673; 8 pin female to 2x big 4 pin female power, 65/70CM, 18AWG,RoHS/REACH; Cable 2; CBL-SAST-0591; MINI SAS HD-4 SATA,6G,INT,RF,Cross Over,75CM,75CM SB,30AWG; Cable 3; CBL-SAST-0655; MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,47CM,SB,30AWG; Cable 4; CBL-SAST-0656; MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,39CM,SB,30AWG; Cable 5; CBL-SAST-0657; MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,55CM,SB,30AWG; Air Shroud; MCP-310-82921-0N; Plastic air shroud for SC829U, 219U (X11 24DIMM, left side); Air Shroud; MCP-310-82922-0N; Plastic air shroud for SC829U, 219U (X11 24DIMM, right side); Riser Card; RSC-R1UW-E8R; 1U RHS WIO Riser card with one PCI-E x8 slot; Riser Card; RSC-R2UW-4E8; 2U LHS WIO Riser card with four PCI-E x4 slots; Heatsink / Retention; SNK-P0068PS; 2U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; * Power Supply; PWS-1K02A-1R; 1U 1000W Redundant Power Supply 73.5mm width Titanium Level,RoHS/REACH; * Cable 6; CBL-0088L; 4 PIN MIDDLE FAN POWER CABLE (PWM). 27cm, 24AWG; * Cable 7; CBL-0160L; NEMA5-15P to C13 US power cord 16AWG 6ft, PBF (default for high watt); * Cable 8; CBL-0318L; CBL,FRONT CNTL,16 TO 16 PIN,RA,RND TUBE,24CM,28AWG; * FAN 1; FAN-0118L4; 80 x 80 x 38 mm, 9.5K RPM, 4-pin PWM Fan, Hot; * Drive Tray(s); MCP-220-00147-0B; Black gen-3 hot-swap 2.5"; Tool-less HDD tray (clip design); * Rail Set; MCP-290-00057-0N; Rail set, quick/quick, default for 4U 17.2"; W; * Rail Set; MCP-290-00060-0N; Threaded rail adapter default for round hole rack; * Air Shroud; MCP-310-81905-0B; Plastic air shroud for SC819U, 119U, 829U, 219U (PWS),RoHS/REACH; * Front Panel; Front panel adaptor board (TB826) forSC826,213,216,219; * Rail Set; MCP-290-00115-0N; Inner rail, quick-release type; * Rail Set; MCP-290-00117-0N; Outer rail, quick-release type; Part Number; Description; Motherboard / Chassis; MBD-X11DPU CSE-219U2TS-R1K02P-T; Super X11DPU Motherboard 2U Chassis; Add-on Card / Module; AOC-2UR68-I2XS; 2U Ultra Riser based on Intel 82599ES controller with 2 10Gb SFP+ ports, 1 internal PCI-E x8 3.0 slot, 1 PCI-E x16 3.0, and I PCI-E x8 3.0 (in x16 slot); Backplane; BPN-SAS3-216A-N4; 24-port 2U SAS3 12Gbps hybrid backplane, support up to 20x 2.5-inch SAS3/SATA3 HDD/SSD and 4x SAS3/SATA3/NVMe Storage Devices; Cable 1; CBL-PWEX-0673; 8 pin female to 2x big 4 pin female power, 65/70CM, 18AWG,RoHS/REACH; Cable 2; CBL-SAST-0591; MINI SAS HD-4 SATA,6G,INT,RF,Cross Over,75CM,75CM SB,30AWG; Cable 3; CBL-SAST-0655; MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,47CM,SB,30AWG; Cable 4; CBL-SAST-0656; MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,39CM,SB,30AWG; Cable 5; CBL-SAST-0657; MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,55CM,SB,30AWG; Air Shroud; MCP-310-82921-0N; Plastic air shroud for SC829U, 219U (X11 24DIMM, left side); Air Shroud; MCP-310-82922-0N; Plastic air shroud for SC829U, 219U (X11 24DIMM, right side); Riser Card; RSC-R1UW-E8R; 1U RHS WIO Riser card with one PCI-E x8 slot; Riser Card; RSC-R2UW-4E8; 2U LHS WIO Riser card with four PCI-E x4 slots; Heatsink / Retention; SNK-P0068PS; 2U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; * Power Supply; PWS-1K02A-1R; 1U 1000W Redundant Power Supply 73.5mm width Titanium Level,RoHS/REACH; * Cable 6; CBL-0088L; 4 PIN MIDDLE FAN POWER CABLE (PWM). 27cm, 24AWG; * Cable 7; CBL-0160L; NEMA5-15P to C13 US power cord 16AWG 6ft, PBF (default for high watt); * Cable 8; CBL-0318L; CBL,FRONT CNTL,16 TO 16 PIN,RA,RND TUBE,24CM,28AWG; * FAN 1; FAN-0118L4; 80 x 80 x 38 mm, 9.5K RPM, 4-pin PWM Fan, Hot; * Drive Tray(s); MCP-220-00147-0B; Black gen-3 hot-swap 2.5"; Tool-less HDD tray (clip design); * Rail Set; MCP-290-00057-0N; Rail set, quick/quick, default for 4U 17.2"; W; * Rail Set; MCP-290-00060-0N; Threaded rail adapter default for round hole rack; * Air Shroud; MCP-310-81905-0B; Plastic air shroud for SC819U, 119U, 829U, 219U (PWS),RoHS/REACH; * Front Panel; Front panel adaptor board (TB826) forSC826,213,216,219; * Rail Set; MCP-290-00115-0N; Inner rail, quick-release type; * Rail Set; MCP-290-00117-0N; Outer rail, quick-release type |
| Optional Parts List | Part Number; Description; Add-on card for internal M.2 NVMe; AOC-SLG3-2M2; Low Profile PCI-E x8 add-on card supports 2 PCI-E 3.0 x4 M-Key M.2 NVMe Modules; 2U Cable Management Arm; MCP-290-00128-0N & MCP-290-00127-0N; 2U Supermicro Cable Management Arm 2nd Gen (Compatible for racks that are 42" in depth); Internal Drive Tray for Two 2.5" Drives; MCP-120-82916-0N CBL-PWEX-0650 CBL-0080L CBL-0484L Or CBL-SAST-0654 Or CBL-SAST-0948; 1 1 2 2 1 1; Internal drive plate Supports Two 2.5" Drive, PCI slots Power cable for Two internal 2.5" drives SATA3 S-S Cable miniSAS(iPass) to 4 SATA Cable miniSAS HD to 4 SATA Cable; Cable for 4 NVMe Hybrid Drive Bays; 2 CBL-SAST-0929 & 2 CBL-SAST-0972; OCuLink source to MiniSAS HD target V.91,INT,PCIe NVMe SSD, 57CM,34AWG; 2.5" NVMe Drive Trays; MCP-220-00167-0B MCP-220-00127-0B; Tool-less black hot-swap 2.5" NVMe drive tray (Orange tab, w/ key lock, clip design) Black hot-swap 2.5" NVMe drive tray (Orange tab, w/ key lock); 2 Internal M.2 slots (1 SATA, 1 NVMe); RSC-UMR-8 & CBL-SAST-0538 & MCP-120-82924-0N & MCP-310-21902-0N; 1U Ultra RHS Riser Card with 1 PCIE/SATA Hybrid M.2 &1 PCIE X8; 2 Rear 2.5" Hot-swap SATA Drive Bays (Complete System Only); MCP-240-82922-0N-OEM; Rear 2x 2.5" HDDs riser bracket kit for SC829U/219U, tool-less; Storage Control Card and Cable(s); AOC-S3008L-L8e & 2x CBL-SAST-0593 AOC-S3008L-L8i & 2x CBL-SAST-0593 AOC-S3108L-H8iR & 2x CBL-SAST-0593 AOC-S3108L-H8iR-16DD & 2x CBL-SAST-0593; Std LP, 8 internal ports, 12Gb/s per port- Gen3, 122HDD, HBA; MINI SAS HD,12G,INT,60CM,30AWG Std LP, 8 internal ports, 12Gb/s per port- Gen3, 63HDD, RAID 0,1,1E; MINI SAS HD,12G,INT,60CM,30AWG Std LP, 8 internal ports, 12Gb/s per port- Gen3, 240HDD, RAID 0, 1, 5, 6, 10, 50, 60; MINI SAS HD,12G,INT,60CM,30AWG Std LP, 8 internal ports, 12Gb/s per port- Gen3, 16HDD, RAID 0, 1, 5, 6, 10, 50, 60; MINI SAS HD,12G,INT,60CM,30AWG; Compatible Networking Cables and Transceivers for System default Networking (AOC-2UR68-i2XS); Networking Cables and Transceivers Compatibility Matrix; Network Card(s); AOC-SGP-i2/4 AOC-STGN-i1S/i2S AOC-STGF-i2S AOC-STG-i4S AOC-STG-b4S AOC-STG-i2T AOC-STGS-i1/2T AOC-STG-i4T AOC-STG-i2 AOC-S25G-m2S AOC-S40G-i2Q More; - - - - - - - - - - - -; Standard LP, 2/4x GbE RJ45, PCI-E x4, Intel i350 Standard LP, 1/2x 10GbE SFP+, PCI-E x8, Intel 82599EN Standard LP, 2x 10GbE SFP+, PCI-E x8, Intel XL710-BM2 Standard LP, 4x 10GbE SFP+, PCI-E x8, Intel XL710 Standard LP, 4x 10GbE SFP+, PCI-E x8, Broadcom BCM57840S Standard LP, 2x 10GbE RJ45, PCI-E x8, Intel X540 Standard LP, 1/2x 10GbE RJ45, PCI-E x8, Intel X550 Standard LP, 4x 10GbE RJ45, PCI-E x8, Intel XL710 Standard LP, 2x 10GbE CX4, PCI-E x8, Intel 82598EB Standard LP, 2x 25GbE SFP28, Mellanox ConnectX-4 LX EN Standard LP 2-port 40GbE controller, Intel Fortville XL710 AOC Compatibility Matrix; CacheVault(s); BTR-CV3108-U1; CacheVault for Broadcom 3108 with Supercap mounting for 2U Ultra; TPM security module; AOM-TPM-9670H-S AOM-TPM-9671H-S; TCG 2.0 compliant trusted platform module (TPM), Horizontal FF TCG 1.2 compliant trusted platform module (TPM), Horizontal FF; Intel VROC RAID Key; AOC-VROCINTMOD AOC-VROCSTNMOD AOC-VROCPREMOD; Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only) Intel VROC Standard, RAID 0, 1, 10 Intel VROC Premium, RAID 0, 1, 5, 10; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; Add-on card for internal M.2 NVMe; AOC-SLG3-2M2; Low Profile PCI-E x8 add-on card supports 2 PCI-E 3.0 x4 M-Key M.2 NVMe Modules; 2U Cable Management Arm; MCP-290-00128-0N & MCP-290-00127-0N; 2U Supermicro Cable Management Arm 2nd Gen (Compatible for racks that are 42" in depth); Internal Drive Tray for Two 2.5" Drives; MCP-120-82916-0N CBL-PWEX-0650 CBL-0080L CBL-0484L Or CBL-SAST-0654 Or CBL-SAST-0948; 1 1 2 2 1 1; Internal drive plate Supports Two 2.5" Drive, PCI slots Power cable for Two internal 2.5" drives SATA3 S-S Cable miniSAS(iPass) to 4 SATA Cable miniSAS HD to 4 SATA Cable; Cable for 4 NVMe Hybrid Drive Bays; 2 CBL-SAST-0929 & 2 CBL-SAST-0972; OCuLink source to MiniSAS HD target V.91,INT,PCIe NVMe SSD, 57CM,34AWG; 2.5" NVMe Drive Trays; MCP-220-00167-0B MCP-220-00127-0B; Tool-less black hot-swap 2.5" NVMe drive tray (Orange tab, w/ key lock, clip design) Black hot-swap 2.5" NVMe drive tray (Orange tab, w/ key lock); 2 Internal M.2 slots (1 SATA, 1 NVMe); RSC-UMR-8 & CBL-SAST-0538 & MCP-120-82924-0N & MCP-310-21902-0N; 1U Ultra RHS Riser Card with 1 PCIE/SATA Hybrid M.2 &1 PCIE X8; 2 Rear 2.5" Hot-swap SATA Drive Bays (Complete System Only); MCP-240-82922-0N-OEM; Rear 2x 2.5" HDDs riser bracket kit for SC829U/219U, tool-less; Storage Control Card and Cable(s); AOC-S3008L-L8e & 2x CBL-SAST-0593 AOC-S3008L-L8i & 2x CBL-SAST-0593 AOC-S3108L-H8iR & 2x CBL-SAST-0593 AOC-S3108L-H8iR-16DD & 2x CBL-SAST-0593; Std LP, 8 internal ports, 12Gb/s per port- Gen3, 122HDD, HBA; MINI SAS HD,12G,INT,60CM,30AWG Std LP, 8 internal ports, 12Gb/s per port- Gen3, 63HDD, RAID 0,1,1E; MINI SAS HD,12G,INT,60CM,30AWG Std LP, 8 internal ports, 12Gb/s per port- Gen3, 240HDD, RAID 0, 1, 5, 6, 10, 50, 60; MINI SAS HD,12G,INT,60CM,30AWG Std LP, 8 internal ports, 12Gb/s per port- Gen3, 16HDD, RAID 0, 1, 5, 6, 10, 50, 60; MINI SAS HD,12G,INT,60CM,30AWG; Compatible Networking Cables and Transceivers for System default Networking (AOC-2UR68-i2XS); Networking Cables and Transceivers Compatibility Matrix; Network Card(s); AOC-SGP-i2/4 AOC-STGN-i1S/i2S AOC-STGF-i2S AOC-STG-i4S AOC-STG-b4S AOC-STG-i2T AOC-STGS-i1/2T AOC-STG-i4T AOC-STG-i2 AOC-S25G-m2S AOC-S40G-i2Q More; - - - - - - - - - - - -; Standard LP, 2/4x GbE RJ45, PCI-E x4, Intel i350 Standard LP, 1/2x 10GbE SFP+, PCI-E x8, Intel 82599EN Standard LP, 2x 10GbE SFP+, PCI-E x8, Intel XL710-BM2 Standard LP, 4x 10GbE SFP+, PCI-E x8, Intel XL710 Standard LP, 4x 10GbE SFP+, PCI-E x8, Broadcom BCM57840S Standard LP, 2x 10GbE RJ45, PCI-E x8, Intel X540 Standard LP, 1/2x 10GbE RJ45, PCI-E x8, Intel X550 Standard LP, 4x 10GbE RJ45, PCI-E x8, Intel XL710 Standard LP, 2x 10GbE CX4, PCI-E x8, Intel 82598EB Standard LP, 2x 25GbE SFP28, Mellanox ConnectX-4 LX EN Standard LP 2-port 40GbE controller, Intel Fortville XL710 AOC Compatibility Matrix; CacheVault(s); BTR-CV3108-U1; CacheVault for Broadcom 3108 with Supercap mounting for 2U Ultra; TPM security module; AOM-TPM-9670H-S AOM-TPM-9671H-S; TCG 2.0 compliant trusted platform module (TPM), Horizontal FF TCG 1.2 compliant trusted platform module (TPM), Horizontal FF; Intel VROC RAID Key; AOC-VROCINTMOD AOC-VROCSTNMOD AOC-VROCPREMOD; Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only) Intel VROC Standard, RAID 0, 1, 10 Intel VROC Premium, RAID 0, 1, 5, 10; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; Add-on card for internal M.2 NVMe; AOC-SLG3-2M2; Low Profile PCI-E x8 add-on card supports 2 PCI-E 3.0 x4 M-Key M.2 NVMe Modules; 2U Cable Management Arm; MCP-290-00128-0N & MCP-290-00127-0N; 2U Supermicro Cable Management Arm 2nd Gen (Compatible for racks that are 42" in depth); Internal Drive Tray for Two 2.5" Drives; MCP-120-82916-0N CBL-PWEX-0650 CBL-0080L CBL-0484L Or CBL-SAST-0654 Or CBL-SAST-0948; 1 1 2 2 1 1; Internal drive plate Supports Two 2.5" Drive, PCI slots Power cable for Two internal 2.5" drives SATA3 S-S Cable miniSAS(iPass) to 4 SATA Cable miniSAS HD to 4 SATA Cable; Cable for 4 NVMe Hybrid Drive Bays; 2 CBL-SAST-0929 & 2 CBL-SAST-0972; OCuLink source to MiniSAS HD target V.91,INT,PCIe NVMe SSD, 57CM,34AWG; 2.5" NVMe Drive Trays; MCP-220-00167-0B MCP-220-00127-0B; Tool-less black hot-swap 2.5" NVMe drive tray (Orange tab, w/ key lock, clip design) Black hot-swap 2.5" NVMe drive tray (Orange tab, w/ key lock); 2 Internal M.2 slots (1 SATA, 1 NVMe); RSC-UMR-8 & CBL-SAST-0538 & MCP-120-82924-0N & MCP-310-21902-0N; 1U Ultra RHS Riser Card with 1 PCIE/SATA Hybrid M.2 &1 PCIE X8; 2 Rear 2.5" Hot-swap SATA Drive Bays (Complete System Only); MCP-240-82922-0N-OEM; Rear 2x 2.5" HDDs riser bracket kit for SC829U/219U, tool-less; Storage Control Card and Cable(s); AOC-S3008L-L8e & 2x CBL-SAST-0593 AOC-S3008L-L8i & 2x CBL-SAST-0593 AOC-S3108L-H8iR & 2x CBL-SAST-0593 AOC-S3108L-H8iR-16DD & 2x CBL-SAST-0593; Std LP, 8 internal ports, 12Gb/s per port- Gen3, 122HDD, HBA; MINI SAS HD,12G,INT,60CM,30AWG Std LP, 8 internal ports, 12Gb/s per port- Gen3, 63HDD, RAID 0,1,1E; MINI SAS HD,12G,INT,60CM,30AWG Std LP, 8 internal ports, 12Gb/s per port- Gen3, 240HDD, RAID 0, 1, 5, 6, 10, 50, 60; MINI SAS HD,12G,INT,60CM,30AWG Std LP, 8 internal ports, 12Gb/s per port- Gen3, 16HDD, RAID 0, 1, 5, 6, 10, 50, 60; MINI SAS HD,12G,INT,60CM,30AWG; Compatible Networking Cables and Transceivers for System default Networking (AOC-2UR68-i2XS); Networking Cables and Transceivers Compatibility Matrix; Network Card(s); AOC-SGP-i2/4 AOC-STGN-i1S/i2S AOC-STGF-i2S AOC-STG-i4S AOC-STG-b4S AOC-STG-i2T AOC-STGS-i1/2T AOC-STG-i4T AOC-STG-i2 AOC-S25G-m2S AOC-S40G-i2Q More; - - - - - - - - - - - -; Standard LP, 2/4x GbE RJ45, PCI-E x4, Intel i350 Standard LP, 1/2x 10GbE SFP+, PCI-E x8, Intel 82599EN Standard LP, 2x 10GbE SFP+, PCI-E x8, Intel XL710-BM2 Standard LP, 4x 10GbE SFP+, PCI-E x8, Intel XL710 Standard LP, 4x 10GbE SFP+, PCI-E x8, Broadcom BCM57840S Standard LP, 2x 10GbE RJ45, PCI-E x8, Intel X540 Standard LP, 1/2x 10GbE RJ45, PCI-E x8, Intel X550 Standard LP, 4x 10GbE RJ45, PCI-E x8, Intel XL710 Standard LP, 2x 10GbE CX4, PCI-E x8, Intel 82598EB Standard LP, 2x 25GbE SFP28, Mellanox ConnectX-4 LX EN Standard LP 2-port 40GbE controller, Intel Fortville XL710 AOC Compatibility Matrix; CacheVault(s); BTR-CV3108-U1; CacheVault for Broadcom 3108 with Supercap mounting for 2U Ultra; TPM security module; AOM-TPM-9670H-S AOM-TPM-9671H-S; TCG 2.0 compliant trusted platform module (TPM), Horizontal FF TCG 1.2 compliant trusted platform module (TPM), Horizontal FF; Intel VROC RAID Key; AOC-VROCINTMOD AOC-VROCSTNMOD AOC-VROCPREMOD; Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only) Intel VROC Standard, RAID 0, 1, 10 Intel VROC Premium, RAID 0, 1, 5, 10; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; Add-on card for internal M.2 NVMe; AOC-SLG3-2M2; Low Profile PCI-E x8 add-on card supports 2 PCI-E 3.0 x4 M-Key M.2 NVMe Modules; 2U Cable Management Arm; MCP-290-00128-0N & MCP-290-00127-0N; 2U Supermicro Cable Management Arm 2nd Gen (Compatible for racks that are 42" in depth); Internal Drive Tray for Two 2.5" Drives; MCP-120-82916-0N CBL-PWEX-0650 CBL-0080L CBL-0484L Or CBL-SAST-0654 Or CBL-SAST-0948; 1 1 2 2 1 1; Internal drive plate Supports Two 2.5" Drive, PCI slots Power cable for Two internal 2.5" drives SATA3 S-S Cable miniSAS(iPass) to 4 SATA Cable miniSAS HD to 4 SATA Cable; Cable for 4 NVMe Hybrid Drive Bays; 2 CBL-SAST-0929 & 2 CBL-SAST-0972; OCuLink source to MiniSAS HD target V.91,INT,PCIe NVMe SSD, 57CM,34AWG; 2.5" NVMe Drive Trays; MCP-220-00167-0B MCP-220-00127-0B; Tool-less black hot-swap 2.5" NVMe drive tray (Orange tab, w/ key lock, clip design) Black hot-swap 2.5" NVMe drive tray (Orange tab, w/ key lock); 2 Internal M.2 slots (1 SATA, 1 NVMe); RSC-UMR-8 & CBL-SAST-0538 & MCP-120-82924-0N & MCP-310-21902-0N; 1U Ultra RHS Riser Card with 1 PCIE/SATA Hybrid M.2 &1 PCIE X8; 2 Rear 2.5" Hot-swap SATA Drive Bays (Complete System Only); MCP-240-82922-0N-OEM; Rear 2x 2.5" HDDs riser bracket kit for SC829U/219U, tool-less; Storage Control Card and Cable(s); AOC-S3008L-L8e & 2x CBL-SAST-0593 AOC-S3008L-L8i & 2x CBL-SAST-0593 AOC-S3108L-H8iR & 2x CBL-SAST-0593 AOC-S3108L-H8iR-16DD & 2x CBL-SAST-0593; Std LP, 8 internal ports, 12Gb/s per port- Gen3, 122HDD, HBA; MINI SAS HD,12G,INT,60CM,30AWG Std LP, 8 internal ports, 12Gb/s per port- Gen3, 63HDD, RAID 0,1,1E; MINI SAS HD,12G,INT,60CM,30AWG Std LP, 8 internal ports, 12Gb/s per port- Gen3, 240HDD, RAID 0, 1, 5, 6, 10, 50, 60; MINI SAS HD,12G,INT,60CM,30AWG Std LP, 8 internal ports, 12Gb/s per port- Gen3, 16HDD, RAID 0, 1, 5, 6, 10, 50, 60; MINI SAS HD,12G,INT,60CM,30AWG; Compatible Networking Cables and Transceivers for System default Networking (AOC-2UR68-i2XS); Networking Cables and Transceivers Compatibility Matrix; Network Card(s); AOC-SGP-i2/4 AOC-STGN-i1S/i2S AOC-STGF-i2S AOC-STG-i4S AOC-STG-b4S AOC-STG-i2T AOC-STGS-i1/2T AOC-STG-i4T AOC-STG-i2 AOC-S25G-m2S AOC-S40G-i2Q More; - - - - - - - - - - - -; Standard LP, 2/4x GbE RJ45, PCI-E x4, Intel i350 Standard LP, 1/2x 10GbE SFP+, PCI-E x8, Intel 82599EN Standard LP, 2x 10GbE SFP+, PCI-E x8, Intel XL710-BM2 Standard LP, 4x 10GbE SFP+, PCI-E x8, Intel XL710 Standard LP, 4x 10GbE SFP+, PCI-E x8, Broadcom BCM57840S Standard LP, 2x 10GbE RJ45, PCI-E x8, Intel X540 Standard LP, 1/2x 10GbE RJ45, PCI-E x8, Intel X550 Standard LP, 4x 10GbE RJ45, PCI-E x8, Intel XL710 Standard LP, 2x 10GbE CX4, PCI-E x8, Intel 82598EB Standard LP, 2x 25GbE SFP28, Mellanox ConnectX-4 LX EN Standard LP 2-port 40GbE controller, Intel Fortville XL710 AOC Compatibility Matrix; CacheVault(s); BTR-CV3108-U1; CacheVault for Broadcom 3108 with Supercap mounting for 2U Ultra; TPM security module; AOM-TPM-9670H-S AOM-TPM-9671H-S; TCG 2.0 compliant trusted platform module (TPM), Horizontal FF TCG 1.2 compliant trusted platform module (TPM), Horizontal FF; Intel VROC RAID Key; AOC-VROCINTMOD AOC-VROCSTNMOD AOC-VROCPREMOD; Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only) Intel VROC Standard, RAID 0, 1, 10 Intel VROC Premium, RAID 0, 1, 5, 10; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license) |
| Management - Software | Intel® Node Manager Redfish API IPMI 2.0 KVM with dedicated LAN NMI SSM , SPM , SUM SuperDoctor® 5 |
| Management - Power Configurations | ACPI Power Management |
| Input Output - DOM | 2 Super DOM (Disk on Module) ports |
| On-Board Devices - Graphics | ASPEED AST2500 BMC |
| PC Health Monitoring - CPU | Monitors for CPU Cores, Chipset Voltages, Memory. 4+1 Phase-switching voltage regulator |
| Processor - Cores | Up to 28 Cores |
| System Memory - Note | † 2933MHz in two DIMMs per channel can be achieved by using memory purchased from Supermicro †† Cascade Lake only. Contact your Supermicro sales rep for more info. |
| Operating Environment - RoHS | RoHS Compliant |
| Operating Environment - Environmental Spec | Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F) Non-operating Temperature: -40°C to 70°C (-40°F to 158°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) |
| On-Board Devices - Network Connectivity | 2 10G SFP+ ports via AOC-2UR68-i2XS (Intel® 82599ES) |
| Drive Bays Storage - Hot-swap | 24 Hot-swap 2.5" drive bays; 14 SATA3 (optional 20 SAS3 + 4 NVMe/SAS3) |
| Drive Bays Storage - M2 | 1 M.2 PCI-E 3.0 x4 M-Key NVMe or 1 M.2 M-Key SATA3 (2240/2260/2280/22110) via optional riser card (see optional parts list) 2 M.2 PCI-E 3.0 x4 M-Key NVMe (2260/2280/22110) via optional add-on card AOC-SLG3-2M2 |
| Power Supply - Total Output Power | 800W: 100 – 127Vac 1000W: 200 – 240Vac 1000W: 200 – 240Vdc (for CCC only) |
| Power Supply - DimensionW x H x L | 73.5 x 40 x 203 mm |
| Power Supply - Input | 100-127Vac / 9.8 - 7A / 50-60Hz 200-240Vac / 7 - 5A / 50-60Hz 200-240Vdc / 7 - 5A (for CCC only) |
| Power Supply - 12Vsb | Max: 2.1A / Min: 0A |
| Power Supply - Output Type | 25 Pairs Gold Finger Connector |
| Input Output - Serial Header | 1 Serial header |
| Product SKUs - SYS-2029U-TRTP | SuperServer 2029U-TRTP ( Black ) |
Отзывы
Загрузка отзывов...
Добавить отзыв
Оплачивайте покупки удобным способом. В интернет-магазине доступно 3 варианта оплаты:
- Наличные при самовывозе или доставке курьером. Специалист свяжется с вами в день доставки, чтобы уточнить время и заранее подготовить сдачу с любой купюры. Вы подписываете товаросопроводительные документы, вносите денежные средства, получаете товар и чек.
- Безналичный расчет при самовывозе или оформлении в интернет-магазине: карты МИР, Visa и MasterCard. Чтобы оплатить покупку, система перенаправит вас на сервер системы ASSIST. Здесь нужно ввести номер карты, срок действия и имя держателя.
- ЮMoney при онлайн-заказе. Для совершения покупки система перенаправит вас на страницу платежного сервиса. Здесь необходимо заполнить форму по инструкции.
Экономьте время на получении заказа. В интернет-магазине доступно 4 варианта доставки:
- Курьерская доставка работает с 9.00 до 19.00. Когда товар поступит на склад, курьерская служба свяжется для уточнения деталей. Специалист предложит выбрать удобное время доставки и уточнит адрес. Осмотрите упаковку на целостность и соответствие указанной комплектации.
- Самовывоз из магазина. Список торговых точек для выбора появится в корзине. Когда заказ поступит на склад, вам придет уведомление. Для получения заказа обратитесь к сотруднику в кассовой зоне и назовите номер.
- Постамат. Когда заказ поступит на точку, на ваш телефон или e-mail придет уникальный код. Заказ нужно оплатить в терминале постамата. Срок хранения — 3 дня.
- Почтовая доставка через почту России. Когда заказ придет в отделение, на ваш адрес придет извещение о посылке. Перед оплатой вы можете оценить состояние коробки: вес, целостность. Вскрывать коробку самостоятельно вы можете только после оплаты заказа. Один заказ может содержать не больше 10 позиций и его стоимость не должна превышать 100 000 р.