SuperServer 4029GP-TRT2
Арт. SYS-2049U-TR4
Продается и поддерживается только в составе готовой системы
Нашли дешевле?
| Motherboard | Super X11QPH+; Super X11QPH+; Super X11QPH+; Super X11QPH+ |
| Processor - CPU | Quad Socket P (LGA 3647) 2nd Gen Intel® Xeon® Scalable Processors and Intel® Xeon® Scalable Processors ‡ , 3 UPI up to 10.4GT/s Support CPU TDP 70-165W with IVR, 205W supported with optional kit |
| Processor - Note | ‡ BIOS version 3.0 or above is required to support 2nd Gen Intel® Xeon® Scalable processors |
| System Memory - Memory Capacity | 48 DIMM slots Up to 12TB 3DS ECC DDR4-2933MHz † RDIMM/LRDIMM Supports Intel® Optane™ DCPMM †† |
| System Memory - Memory Type | 2933 † /2666MHz ECC DDR4 RDIMM/LRDIMM |
| On-Board Devices - Chipset | Intel® C621 chipset |
| On-Board Devices - SATA | SATA3 via Intel C621; RAID 0, 1, 5, 10 |
| On-Board Devices - IPMI | Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support |
| Input Output - SATA | 12 SATA3 (6Gbps) ports |
| Input Output - LAN | 4 RJ45 GbE LAN ports 1 RJ45 Dedicated IPMI LAN port |
| Input Output - USB | 2 USB 3.0 ports (rear) |
| Input Output - Video | 1 VGA Connector |
| Input Output - Serial Port Header | 1 COM port (rear) |
| PC Health Monitoring - FAN | Fans with tachometer monitoring Status monitor for speed control Pulse Width Modulated (PWM) fan connectors |
| PC Health Monitoring - Temperature | Monitoring for CPU and chassis environment Thermal Control for fan connectors |
| Chassis - Form Factor | 2U Rackmount |
| Chassis - Model | CSE-218UTS-R1K62P |
| Dimensions and Weight - Height | 3.5" (89mm) |
| Dimensions and Weight - Width | 17.2" (437mm) |
| Dimensions and Weight - Depth | 30.7" (780mm) |
| Dimensions and Weight - Weight | Net Weight: 43 lbs (19.4 kg) Gross Weight: 69 lbs (31.2 kg) |
| Dimensions and Weight - Available Colors | Black |
| Front Panel - Buttons | Power On/Off button System Reset button |
| Front Panel - LEDs | Power status LED HDD activity LED Network activity LEDs System information (overheat/UID) LED |
| Expansion Slots - PCI-Express | 5 PCI-E 3.0 x8 slots 6 PCI-E 3.0 x16 slots (4 CPUs need to be installed for full access to PCI-E slots and onboard controllers. See AOC Support for details.) |
| Drive Bays - Hot-swap | 24 Hot-swap 2.5" SAS3/SATA3 drive bays Optional 24 SAS3 ports via AOC Optional 20 SAS3 ports via AOC + 4 NVMe ports via AOC |
| System Cooling - Fans | 4x 8cm heavy duty PWM fans |
| Power Supply | 1600W Redundant Power Supplies with PMBus; 1600W Redundant Power Supplies with PMBus; 1600W Redundant Power Supplies with PMBus; 1600W Redundant Power Supplies with PMBus |
| Power Supply - 12V | Max: 83.3A / Min: 0A (100-127Vac) Max: 133A / Min: 0A (200-240Vac) |
| Power Supply - Certification | Titanium Level [ Test Report ] |
| System BIOS - BIOS Type | 128Mb SPI Flash EEPROM with AMI BIOS |
| Parts List - Items Included | Part Number; Description; Motherboard / Chassis; MBD-X11QPH+ CSE-218UTS-R1K62P; Super X11QPH+ Motherboard 2U Chassis; Add-on Card / Module; AOC-2UR66-I4G; 2U Ultra Riser with 4 GbE ports and 2 PCI-E x16 3.0, Intel i350; Backplane; BPN-SAS3-216A-N4; 24-port 2U SAS3 12Gbps hybrid backplane, support up to 20x 2.5-inch SAS3/SATA3 HDD/SSD and 4x SAS3/SATA3/NVMe Storage Devices; Cable 1; CBL-PWEX-0673; 8 pin female to 2x big 4 pin female power, 65/70CM, 18AWG,RoHS/REACH; Cable 2; CBL-SAST-0701; MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,85CM,SB,30AWG,Ro; Riser Card; RSC-R1UW-E8R; 1U RHS WIO Riser card with one PCI-E x8 slot; Riser Card; RSC-R2UW-4E8; 2U LHS WIO Riser card with four PCI-E x8 slots; Riser Card; RSC-S2-66; 2U Passive Standard Riser Card with two PCI-E 3.0 x16 Slots,; Heatsink / Retention; SNK-P0067PS; 1U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Heatsink / Retention; SNK-P0067PSMB; 1U Passive High Performance Front CPU Heat Sink w/ an 18-mm Wide Middle Air Channel for X11 Purley Platform Equipped w/ a Narrow Retention Mechanism/Bolster; Power Supply; PWS-1K62A-1R; AC-DC 1600W, Titanium Level, Redundancy, 1U, DC Output: +12V and +12Vs, 203 x 73.5 x 40 mm, AC Input: 90 - 264 VAC/47-63Hz, PMBus 1.2 with DSP controller,HF,RoHS/REACH; FAN-0166L4; 80x80x38 mm, 13.5K RPM, Optional Middle Cooling Fan for 2U Ultra Series Servers (Hot-swappable Version of FAN-0162L4); Part Number; Description; Motherboard / Chassis; MBD-X11QPH+ CSE-218UTS-R1K62P; Super X11QPH+ Motherboard 2U Chassis; Add-on Card / Module; AOC-2UR66-I4G; 2U Ultra Riser with 4 GbE ports and 2 PCI-E x16 3.0, Intel i350; Backplane; BPN-SAS3-216A-N4; 24-port 2U SAS3 12Gbps hybrid backplane, support up to 20x 2.5-inch SAS3/SATA3 HDD/SSD and 4x SAS3/SATA3/NVMe Storage Devices; Cable 1; CBL-PWEX-0673; 8 pin female to 2x big 4 pin female power, 65/70CM, 18AWG,RoHS/REACH; Cable 2; CBL-SAST-0701; MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,85CM,SB,30AWG,Ro; Riser Card; RSC-R1UW-E8R; 1U RHS WIO Riser card with one PCI-E x8 slot; Riser Card; RSC-R2UW-4E8; 2U LHS WIO Riser card with four PCI-E x8 slots; Riser Card; RSC-S2-66; 2U Passive Standard Riser Card with two PCI-E 3.0 x16 Slots,; Heatsink / Retention; SNK-P0067PS; 1U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Heatsink / Retention; SNK-P0067PSMB; 1U Passive High Performance Front CPU Heat Sink w/ an 18-mm Wide Middle Air Channel for X11 Purley Platform Equipped w/ a Narrow Retention Mechanism/Bolster; Power Supply; PWS-1K62A-1R; AC-DC 1600W, Titanium Level, Redundancy, 1U, DC Output: +12V and +12Vs, 203 x 73.5 x 40 mm, AC Input: 90 - 264 VAC/47-63Hz, PMBus 1.2 with DSP controller,HF,RoHS/REACH; FAN-0166L4; 80x80x38 mm, 13.5K RPM, Optional Middle Cooling Fan for 2U Ultra Series Servers (Hot-swappable Version of FAN-0162L4); Part Number; Description; Motherboard / Chassis; MBD-X11QPH+ CSE-218UTS-R1K62P; Super X11QPH+ Motherboard 2U Chassis; Add-on Card / Module; AOC-2UR66-I4G; 2U Ultra Riser with 4 GbE ports and 2 PCI-E x16 3.0, Intel i350; Backplane; BPN-SAS3-216A-N4; 24-port 2U SAS3 12Gbps hybrid backplane, support up to 20x 2.5-inch SAS3/SATA3 HDD/SSD and 4x SAS3/SATA3/NVMe Storage Devices; Cable 1; CBL-PWEX-0673; 8 pin female to 2x big 4 pin female power, 65/70CM, 18AWG,RoHS/REACH; Cable 2; CBL-SAST-0701; MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,85CM,SB,30AWG,Ro; Riser Card; RSC-R1UW-E8R; 1U RHS WIO Riser card with one PCI-E x8 slot; Riser Card; RSC-R2UW-4E8; 2U LHS WIO Riser card with four PCI-E x8 slots; Riser Card; RSC-S2-66; 2U Passive Standard Riser Card with two PCI-E 3.0 x16 Slots,; Heatsink / Retention; SNK-P0067PS; 1U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Heatsink / Retention; SNK-P0067PSMB; 1U Passive High Performance Front CPU Heat Sink w/ an 18-mm Wide Middle Air Channel for X11 Purley Platform Equipped w/ a Narrow Retention Mechanism/Bolster; Power Supply; PWS-1K62A-1R; AC-DC 1600W, Titanium Level, Redundancy, 1U, DC Output: +12V and +12Vs, 203 x 73.5 x 40 mm, AC Input: 90 - 264 VAC/47-63Hz, PMBus 1.2 with DSP controller,HF,RoHS/REACH; FAN-0166L4; 80x80x38 mm, 13.5K RPM, Optional Middle Cooling Fan for 2U Ultra Series Servers (Hot-swappable Version of FAN-0162L4); Part Number; Description; Motherboard / Chassis; MBD-X11QPH+ CSE-218UTS-R1K62P; Super X11QPH+ Motherboard 2U Chassis; Add-on Card / Module; AOC-2UR66-I4G; 2U Ultra Riser with 4 GbE ports and 2 PCI-E x16 3.0, Intel i350; Backplane; BPN-SAS3-216A-N4; 24-port 2U SAS3 12Gbps hybrid backplane, support up to 20x 2.5-inch SAS3/SATA3 HDD/SSD and 4x SAS3/SATA3/NVMe Storage Devices; Cable 1; CBL-PWEX-0673; 8 pin female to 2x big 4 pin female power, 65/70CM, 18AWG,RoHS/REACH; Cable 2; CBL-SAST-0701; MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,85CM,SB,30AWG,Ro; Riser Card; RSC-R1UW-E8R; 1U RHS WIO Riser card with one PCI-E x8 slot; Riser Card; RSC-R2UW-4E8; 2U LHS WIO Riser card with four PCI-E x8 slots; Riser Card; RSC-S2-66; 2U Passive Standard Riser Card with two PCI-E 3.0 x16 Slots,; Heatsink / Retention; SNK-P0067PS; 1U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Heatsink / Retention; SNK-P0067PSMB; 1U Passive High Performance Front CPU Heat Sink w/ an 18-mm Wide Middle Air Channel for X11 Purley Platform Equipped w/ a Narrow Retention Mechanism/Bolster; Power Supply; PWS-1K62A-1R; AC-DC 1600W, Titanium Level, Redundancy, 1U, DC Output: +12V and +12Vs, 203 x 73.5 x 40 mm, AC Input: 90 - 264 VAC/47-63Hz, PMBus 1.2 with DSP controller,HF,RoHS/REACH; FAN-0166L4; 80x80x38 mm, 13.5K RPM, Optional Middle Cooling Fan for 2U Ultra Series Servers (Hot-swappable Version of FAN-0162L4) |
| Optional Parts List | Part Number; Description; 2.5" NVMe Drive Trays; MCP-220-00167-0B MCP-220-00127-0B; Tool-less black hot-swap 2.5" NVMe drive tray (Orange tab, w/ key lock, clip design) Black hot-swap 2.5" NVMe drive tray (Orange tab, w/ key lock); Add-on Card; AOC-VROCPREMOD AOC-VROCSTNMOD; Intel VROC Premium, RAID 0, 1, 5, 10 Intel VROC HW key (RSTe) standard upgrade module; Frequency optimized and 205 watt CPU option kit; MCP-240-21904-0N-OEM SNK-P0068PS; RSC bkt set (left, Mid/Right) for SC829/219U (LP),Tool-less 2U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; 2000w power supply kit; MCP-250-21802-0N PWS-2K03P-1R; Power adapter bracket for 2K03P in SC218U,HF,RoHS/REACH 1U 2000W Redundant Power Supply Platinum 73.5mm width; Active Cooling GPU GPU power cable; GPU-NVQRTX8000 GPU-NVQRTX6000 GPU-NVQRTX5000 GPU-NVQRTX4000 GPU-NVK40C GPU-NVQM6000 GPU-NVQM6000-24 GPU-NVQGV100 CBL-PWEX-1042 CBL-PWEX-1040; - - - - - - - - 1/GPU 1/GPU; NVIDIA PNY Quadro RTX8000 48GB GDDR6 PCIe 3.0 NVIDIA PNY Quadro RTX6000 24GB GDDR6 PCIe 3.0 NVIDIA PNY Quadro RTX5000 16GB GDDR6 PCIe 3.0 NVIDIA PNY Quadro RTX4000 8GB GDDR6 PCIe 3.0 NVIDIA Tesla K40 PCI-E 12GB GDDR5 NVIDIA PNY Quadro M6000 12GB GDDR5 PCIe 3.0 NVIDIA PNY Quadro M6000 24GB GDDR5 PCIe 3.0 NVIDIA PNY Quadro GV100 32GB HBM2 PCIe 3.0 GPU, 2x4F/CPU to 2x4F/CPU, P4.2, 50CM, 16AWG, 10A/pin, -40~105C GPU,2x4M/CPU to two (2x3F+2x1F)/PCIe,P4.2, 5CM,16/20AWG, 10.5A/pin(16AWG), 8A/pin(20AWG), -25~85C,RoHS; CacheVault(s); BTR-TFM8G-LSICVM02 & BKT-BBU-BRACKET-05 BTR-TFM8G-LSICVM02 & MCP-240-00127-0N; CacheVault for Broadcom 3108; Supercap mounting bracket for PCI-E location CacheVault for Broadcom 3108; Supercap mounting bracket for 2.5" HDD location; Network Card(s); AOC-S40G-i2Q AOC-SGP-i2 AOC-SGP-i4 AOC-STG-b4S AOC-STGN-i2S AOC-STGN-i1S AOC-STG-i2T; - - - - - - -; Standard LP 2-port 40GbE controller, based on Intel Fortville XL710 Standard LP, 2x GbE RJ45, PCI-E x4, Intel i350AM2 Standard LP, 4x GbE RJ45, PCI-E x4, Intel i350 Standard LP, 4x 10GbE SFP+, PCI-E x8, Broadcom BCM57840S Standard LP, 2x 10GbE SFP+, PCI-E x8, Intel 82599ES Standard LP, 1x 10GbE SFP+, PCI-E x8, Intel 82599EN Standard LP, 2x 10GbE RJ45, PCI-E x8, Intel X540; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; 2.5" NVMe Drive Trays; MCP-220-00167-0B MCP-220-00127-0B; Tool-less black hot-swap 2.5" NVMe drive tray (Orange tab, w/ key lock, clip design) Black hot-swap 2.5" NVMe drive tray (Orange tab, w/ key lock); Add-on Card; AOC-VROCPREMOD AOC-VROCSTNMOD; Intel VROC Premium, RAID 0, 1, 5, 10 Intel VROC HW key (RSTe) standard upgrade module; Frequency optimized and 205 watt CPU option kit; MCP-240-21904-0N-OEM SNK-P0068PS; RSC bkt set (left, Mid/Right) for SC829/219U (LP),Tool-less 2U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; 2000w power supply kit; MCP-250-21802-0N PWS-2K03P-1R; Power adapter bracket for 2K03P in SC218U,HF,RoHS/REACH 1U 2000W Redundant Power Supply Platinum 73.5mm width; Active Cooling GPU GPU power cable; GPU-NVQRTX8000 GPU-NVQRTX6000 GPU-NVQRTX5000 GPU-NVQRTX4000 GPU-NVK40C GPU-NVQM6000 GPU-NVQM6000-24 GPU-NVQGV100 CBL-PWEX-1042 CBL-PWEX-1040; - - - - - - - - 1/GPU 1/GPU; NVIDIA PNY Quadro RTX8000 48GB GDDR6 PCIe 3.0 NVIDIA PNY Quadro RTX6000 24GB GDDR6 PCIe 3.0 NVIDIA PNY Quadro RTX5000 16GB GDDR6 PCIe 3.0 NVIDIA PNY Quadro RTX4000 8GB GDDR6 PCIe 3.0 NVIDIA Tesla K40 PCI-E 12GB GDDR5 NVIDIA PNY Quadro M6000 12GB GDDR5 PCIe 3.0 NVIDIA PNY Quadro M6000 24GB GDDR5 PCIe 3.0 NVIDIA PNY Quadro GV100 32GB HBM2 PCIe 3.0 GPU, 2x4F/CPU to 2x4F/CPU, P4.2, 50CM, 16AWG, 10A/pin, -40~105C GPU,2x4M/CPU to two (2x3F+2x1F)/PCIe,P4.2, 5CM,16/20AWG, 10.5A/pin(16AWG), 8A/pin(20AWG), -25~85C,RoHS; CacheVault(s); BTR-TFM8G-LSICVM02 & BKT-BBU-BRACKET-05 BTR-TFM8G-LSICVM02 & MCP-240-00127-0N; CacheVault for Broadcom 3108; Supercap mounting bracket for PCI-E location CacheVault for Broadcom 3108; Supercap mounting bracket for 2.5" HDD location; Network Card(s); AOC-S40G-i2Q AOC-SGP-i2 AOC-SGP-i4 AOC-STG-b4S AOC-STGN-i2S AOC-STGN-i1S AOC-STG-i2T; - - - - - - -; Standard LP 2-port 40GbE controller, based on Intel Fortville XL710 Standard LP, 2x GbE RJ45, PCI-E x4, Intel i350AM2 Standard LP, 4x GbE RJ45, PCI-E x4, Intel i350 Standard LP, 4x 10GbE SFP+, PCI-E x8, Broadcom BCM57840S Standard LP, 2x 10GbE SFP+, PCI-E x8, Intel 82599ES Standard LP, 1x 10GbE SFP+, PCI-E x8, Intel 82599EN Standard LP, 2x 10GbE RJ45, PCI-E x8, Intel X540; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; 2.5" NVMe Drive Trays; MCP-220-00167-0B MCP-220-00127-0B; Tool-less black hot-swap 2.5" NVMe drive tray (Orange tab, w/ key lock, clip design) Black hot-swap 2.5" NVMe drive tray (Orange tab, w/ key lock); Add-on Card; AOC-VROCPREMOD AOC-VROCSTNMOD; Intel VROC Premium, RAID 0, 1, 5, 10 Intel VROC HW key (RSTe) standard upgrade module; Frequency optimized and 205 watt CPU option kit; MCP-240-21904-0N-OEM SNK-P0068PS; RSC bkt set (left, Mid/Right) for SC829/219U (LP),Tool-less 2U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; 2000w power supply kit; MCP-250-21802-0N PWS-2K03P-1R; Power adapter bracket for 2K03P in SC218U,HF,RoHS/REACH 1U 2000W Redundant Power Supply Platinum 73.5mm width; Active Cooling GPU GPU power cable; GPU-NVQRTX8000 GPU-NVQRTX6000 GPU-NVQRTX5000 GPU-NVQRTX4000 GPU-NVK40C GPU-NVQM6000 GPU-NVQM6000-24 GPU-NVQGV100 CBL-PWEX-1042 CBL-PWEX-1040; - - - - - - - - 1/GPU 1/GPU; NVIDIA PNY Quadro RTX8000 48GB GDDR6 PCIe 3.0 NVIDIA PNY Quadro RTX6000 24GB GDDR6 PCIe 3.0 NVIDIA PNY Quadro RTX5000 16GB GDDR6 PCIe 3.0 NVIDIA PNY Quadro RTX4000 8GB GDDR6 PCIe 3.0 NVIDIA Tesla K40 PCI-E 12GB GDDR5 NVIDIA PNY Quadro M6000 12GB GDDR5 PCIe 3.0 NVIDIA PNY Quadro M6000 24GB GDDR5 PCIe 3.0 NVIDIA PNY Quadro GV100 32GB HBM2 PCIe 3.0 GPU, 2x4F/CPU to 2x4F/CPU, P4.2, 50CM, 16AWG, 10A/pin, -40~105C GPU,2x4M/CPU to two (2x3F+2x1F)/PCIe,P4.2, 5CM,16/20AWG, 10.5A/pin(16AWG), 8A/pin(20AWG), -25~85C,RoHS; CacheVault(s); BTR-TFM8G-LSICVM02 & BKT-BBU-BRACKET-05 BTR-TFM8G-LSICVM02 & MCP-240-00127-0N; CacheVault for Broadcom 3108; Supercap mounting bracket for PCI-E location CacheVault for Broadcom 3108; Supercap mounting bracket for 2.5" HDD location; Network Card(s); AOC-S40G-i2Q AOC-SGP-i2 AOC-SGP-i4 AOC-STG-b4S AOC-STGN-i2S AOC-STGN-i1S AOC-STG-i2T; - - - - - - -; Standard LP 2-port 40GbE controller, based on Intel Fortville XL710 Standard LP, 2x GbE RJ45, PCI-E x4, Intel i350AM2 Standard LP, 4x GbE RJ45, PCI-E x4, Intel i350 Standard LP, 4x 10GbE SFP+, PCI-E x8, Broadcom BCM57840S Standard LP, 2x 10GbE SFP+, PCI-E x8, Intel 82599ES Standard LP, 1x 10GbE SFP+, PCI-E x8, Intel 82599EN Standard LP, 2x 10GbE RJ45, PCI-E x8, Intel X540; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; 2.5" NVMe Drive Trays; MCP-220-00167-0B MCP-220-00127-0B; Tool-less black hot-swap 2.5" NVMe drive tray (Orange tab, w/ key lock, clip design) Black hot-swap 2.5" NVMe drive tray (Orange tab, w/ key lock); Add-on Card; AOC-VROCPREMOD AOC-VROCSTNMOD; Intel VROC Premium, RAID 0, 1, 5, 10 Intel VROC HW key (RSTe) standard upgrade module; Frequency optimized and 205 watt CPU option kit; MCP-240-21904-0N-OEM SNK-P0068PS; RSC bkt set (left, Mid/Right) for SC829/219U (LP),Tool-less 2U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; 2000w power supply kit; MCP-250-21802-0N PWS-2K03P-1R; Power adapter bracket for 2K03P in SC218U,HF,RoHS/REACH 1U 2000W Redundant Power Supply Platinum 73.5mm width; Active Cooling GPU GPU power cable; GPU-NVQRTX8000 GPU-NVQRTX6000 GPU-NVQRTX5000 GPU-NVQRTX4000 GPU-NVK40C GPU-NVQM6000 GPU-NVQM6000-24 GPU-NVQGV100 CBL-PWEX-1042 CBL-PWEX-1040; - - - - - - - - 1/GPU 1/GPU; NVIDIA PNY Quadro RTX8000 48GB GDDR6 PCIe 3.0 NVIDIA PNY Quadro RTX6000 24GB GDDR6 PCIe 3.0 NVIDIA PNY Quadro RTX5000 16GB GDDR6 PCIe 3.0 NVIDIA PNY Quadro RTX4000 8GB GDDR6 PCIe 3.0 NVIDIA Tesla K40 PCI-E 12GB GDDR5 NVIDIA PNY Quadro M6000 12GB GDDR5 PCIe 3.0 NVIDIA PNY Quadro M6000 24GB GDDR5 PCIe 3.0 NVIDIA PNY Quadro GV100 32GB HBM2 PCIe 3.0 GPU, 2x4F/CPU to 2x4F/CPU, P4.2, 50CM, 16AWG, 10A/pin, -40~105C GPU,2x4M/CPU to two (2x3F+2x1F)/PCIe,P4.2, 5CM,16/20AWG, 10.5A/pin(16AWG), 8A/pin(20AWG), -25~85C,RoHS; CacheVault(s); BTR-TFM8G-LSICVM02 & BKT-BBU-BRACKET-05 BTR-TFM8G-LSICVM02 & MCP-240-00127-0N; CacheVault for Broadcom 3108; Supercap mounting bracket for PCI-E location CacheVault for Broadcom 3108; Supercap mounting bracket for 2.5" HDD location; Network Card(s); AOC-S40G-i2Q AOC-SGP-i2 AOC-SGP-i4 AOC-STG-b4S AOC-STGN-i2S AOC-STGN-i1S AOC-STG-i2T; - - - - - - -; Standard LP 2-port 40GbE controller, based on Intel Fortville XL710 Standard LP, 2x GbE RJ45, PCI-E x4, Intel i350AM2 Standard LP, 4x GbE RJ45, PCI-E x4, Intel i350 Standard LP, 4x 10GbE SFP+, PCI-E x8, Broadcom BCM57840S Standard LP, 2x 10GbE SFP+, PCI-E x8, Intel 82599ES Standard LP, 1x 10GbE SFP+, PCI-E x8, Intel 82599EN Standard LP, 2x 10GbE RJ45, PCI-E x8, Intel X540; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license) |
| Input Output - SAS | 24 SAS3 ports support via optional Add-on Cards |
| Management - Software | SuperDoctor® 5 Watch Dog NMI SUM IPMI 2.0 |
| Management - Power Configurations | ACPI Power Management Power-on mode for AC power recovery |
| Input Output - DOM | 2 Super DOM (Disk on Module) ports |
| On-Board Devices - Graphics | ASPEED AST2500 BMC |
| PC Health Monitoring - CPU | Monitors for CPU Cores, Chipset Voltages, Memory. 4+1 Phase-switching voltage regulator |
| Processor - Cores | Up to 28 Cores |
| System Memory - Note | † 2933MHz in two DIMMs per channel can be achieved by using memory purchased from Supermicro †† Cascade Lake only. Contact your Supermicro sales rep for more info. |
| Operating Environment - RoHS | RoHS Compliant |
| Operating Environment - Environmental Spec | Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F) Non-operating Temperature: -40°C to 60°C (-40°F to 140°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) |
| On-Board Devices - Network Connectivity | 4 Gigabit Ethernet ports via AOC-2UR66-i4G; Other options |
| Input Output - NVMe | 4 Hybrid ports with NVMe support via AOC |
| Power Supply - Total Output Power | 1600W/*1000W |
| Power Supply - DimensionW x H x L | 73.5 x 40 x 203 mm |
| Power Supply - Input | *100-127Vac / 13 - 9A / 50-60Hz 200-240Vac / 10 - 8A / 50-60Hz |
| Power Supply - 12Vsb | Max: 2.1A / Min: 0A |
| Power Supply - Output Type | 25 Pairs Gold Finger Connector |
| Product SKUs - SYS-2049U-TR4 | SuperServer 2049U-TR4 ( Black ) |
| Storage Options List | Connection; For 8 SAS3 HDD; AOC-S3008L-L8i x1 or AOC-S3108L-H8iR x1 or AOC-S3108L-H8iR-16DD x1; CBL-SAST-0532 x2; PCI-E slot 8; For 16 SAS3 HDD; AOC-S3008L-L8i x2 or AOC-S3108L-H8iR x2 or AOC-S3108L-H8iR-16DD x2; CBL-SAST-0532 x2 CBL-SAST-0593 x2; PCI-E slot 8 PCI-E slot 9; For 24 SAS3 HDD; AOC-S3008L-L8i x3 or AOC-S3108L-H8iR x3 or AOC-S3108L-H8iR-16DD x3; CBL-SAST-0532 x2 CBL-SAST-0593 x2 CBL-SAST-0568 x2; PCI-E slot 8 PCI-E slot 9 PCI-E slot 11; For 24 SAS3 HDD including 4 NVMe; AOC-S3008L-L8i x3 + AOC-SLG3-4E4T x1 or AOC-S3108L-H8iR x3 + AOC-SLG3-4E4T x1 or AOC-S3108L-H8iR-16DD x 3 + AOC-SLG3-4E4T x1; CBL-SAST-0532 x2 CBL-SAST-0593 x2 CBL-SAST-0568 x2 CBL-SAST-0926 x4 (NVMe cable); PCI-E slot 8 PCI-E slot 9 PCI-E slot 11 PCIE Slot 10 (AOC-SLG3-4E4T); TPM security module (optional, not included); AOM-TPM-9670V AOM-TPM-9671V; TPM module (Vertical) TPM 2.0 TPM module (Vertical) TPM 1.2.; Connection; For 8 SAS3 HDD; AOC-S3008L-L8i x1 or AOC-S3108L-H8iR x1 or AOC-S3108L-H8iR-16DD x1; CBL-SAST-0532 x2; PCI-E slot 8; For 16 SAS3 HDD; AOC-S3008L-L8i x2 or AOC-S3108L-H8iR x2 or AOC-S3108L-H8iR-16DD x2; CBL-SAST-0532 x2 CBL-SAST-0593 x2; PCI-E slot 8 PCI-E slot 9; For 24 SAS3 HDD; AOC-S3008L-L8i x3 or AOC-S3108L-H8iR x3 or AOC-S3108L-H8iR-16DD x3; CBL-SAST-0532 x2 CBL-SAST-0593 x2 CBL-SAST-0568 x2; PCI-E slot 8 PCI-E slot 9 PCI-E slot 11; For 24 SAS3 HDD including 4 NVMe; AOC-S3008L-L8i x3 + AOC-SLG3-4E4T x1 or AOC-S3108L-H8iR x3 + AOC-SLG3-4E4T x1 or AOC-S3108L-H8iR-16DD x 3 + AOC-SLG3-4E4T x1; CBL-SAST-0532 x2 CBL-SAST-0593 x2 CBL-SAST-0568 x2 CBL-SAST-0926 x4 (NVMe cable); PCI-E slot 8 PCI-E slot 9 PCI-E slot 11 PCIE Slot 10 (AOC-SLG3-4E4T); TPM security module (optional, not included); AOM-TPM-9670V AOM-TPM-9671V; TPM module (Vertical) TPM 2.0 TPM module (Vertical) TPM 1.2.; Connection; For 8 SAS3 HDD; AOC-S3008L-L8i x1 or AOC-S3108L-H8iR x1 or AOC-S3108L-H8iR-16DD x1; CBL-SAST-0532 x2; PCI-E slot 8; For 16 SAS3 HDD; AOC-S3008L-L8i x2 or AOC-S3108L-H8iR x2 or AOC-S3108L-H8iR-16DD x2; CBL-SAST-0532 x2 CBL-SAST-0593 x2; PCI-E slot 8 PCI-E slot 9; For 24 SAS3 HDD; AOC-S3008L-L8i x3 or AOC-S3108L-H8iR x3 or AOC-S3108L-H8iR-16DD x3; CBL-SAST-0532 x2 CBL-SAST-0593 x2 CBL-SAST-0568 x2; PCI-E slot 8 PCI-E slot 9 PCI-E slot 11; For 24 SAS3 HDD including 4 NVMe; AOC-S3008L-L8i x3 + AOC-SLG3-4E4T x1 or AOC-S3108L-H8iR x3 + AOC-SLG3-4E4T x1 or AOC-S3108L-H8iR-16DD x 3 + AOC-SLG3-4E4T x1; CBL-SAST-0532 x2 CBL-SAST-0593 x2 CBL-SAST-0568 x2 CBL-SAST-0926 x4 (NVMe cable); PCI-E slot 8 PCI-E slot 9 PCI-E slot 11 PCIE Slot 10 (AOC-SLG3-4E4T); TPM security module (optional, not included); AOM-TPM-9670V AOM-TPM-9671V; TPM module (Vertical) TPM 2.0 TPM module (Vertical) TPM 1.2.; Connection; For 8 SAS3 HDD; AOC-S3008L-L8i x1 or AOC-S3108L-H8iR x1 or AOC-S3108L-H8iR-16DD x1; CBL-SAST-0532 x2; PCI-E slot 8; For 16 SAS3 HDD; AOC-S3008L-L8i x2 or AOC-S3108L-H8iR x2 or AOC-S3108L-H8iR-16DD x2; CBL-SAST-0532 x2 CBL-SAST-0593 x2; PCI-E slot 8 PCI-E slot 9; For 24 SAS3 HDD; AOC-S3008L-L8i x3 or AOC-S3108L-H8iR x3 or AOC-S3108L-H8iR-16DD x3; CBL-SAST-0532 x2 CBL-SAST-0593 x2 CBL-SAST-0568 x2; PCI-E slot 8 PCI-E slot 9 PCI-E slot 11; For 24 SAS3 HDD including 4 NVMe; AOC-S3008L-L8i x3 + AOC-SLG3-4E4T x1 or AOC-S3108L-H8iR x3 + AOC-SLG3-4E4T x1 or AOC-S3108L-H8iR-16DD x 3 + AOC-SLG3-4E4T x1; CBL-SAST-0532 x2 CBL-SAST-0593 x2 CBL-SAST-0568 x2 CBL-SAST-0926 x4 (NVMe cable); PCI-E slot 8 PCI-E slot 9 PCI-E slot 11 PCIE Slot 10 (AOC-SLG3-4E4T); TPM security module (optional, not included); AOM-TPM-9670V AOM-TPM-9671V; TPM module (Vertical) TPM 2.0 TPM module (Vertical) TPM 1.2. |
Отзывы
Загрузка отзывов...
Добавить отзыв
Оплачивайте покупки удобным способом. В интернет-магазине доступно 3 варианта оплаты:
- Наличные при самовывозе или доставке курьером. Специалист свяжется с вами в день доставки, чтобы уточнить время и заранее подготовить сдачу с любой купюры. Вы подписываете товаросопроводительные документы, вносите денежные средства, получаете товар и чек.
- Безналичный расчет при самовывозе или оформлении в интернет-магазине: карты МИР, Visa и MasterCard. Чтобы оплатить покупку, система перенаправит вас на сервер системы ASSIST. Здесь нужно ввести номер карты, срок действия и имя держателя.
- ЮMoney при онлайн-заказе. Для совершения покупки система перенаправит вас на страницу платежного сервиса. Здесь необходимо заполнить форму по инструкции.
Экономьте время на получении заказа. В интернет-магазине доступно 4 варианта доставки:
- Курьерская доставка работает с 9.00 до 19.00. Когда товар поступит на склад, курьерская служба свяжется для уточнения деталей. Специалист предложит выбрать удобное время доставки и уточнит адрес. Осмотрите упаковку на целостность и соответствие указанной комплектации.
- Самовывоз из магазина. Список торговых точек для выбора появится в корзине. Когда заказ поступит на склад, вам придет уведомление. Для получения заказа обратитесь к сотруднику в кассовой зоне и назовите номер.
- Постамат. Когда заказ поступит на точку, на ваш телефон или e-mail придет уникальный код. Заказ нужно оплатить в терминале постамата. Срок хранения — 3 дня.
- Почтовая доставка через почту России. Когда заказ придет в отделение, на ваш адрес придет извещение о посылке. Перед оплатой вы можете оценить состояние коробки: вес, целостность. Вскрывать коробку самостоятельно вы можете только после оплаты заказа. Один заказ может содержать не больше 10 позиций и его стоимость не должна превышать 100 000 р.
