Информация
  • Как купить
  • Доставка
  • Оплата
  • Реквизиты
  • Отзывы
  • Возможности
Услуги
Блог
Контакты
Акции
Компания
  • О компании
  • Лицензии
  • Отзывы
  • Документы
    info@super-micro.ru
    +7 000 000-00-00
    Заказать звонок
    super-micro.ru
    Каталог
    • X14
      X14
      • 10U
      • 1U
      • 2U
      • 3U
      • 4U
      • 5U
      • 8U
      • Fan-based Embedded
      • Mid-Tower
    • X13
      X13
      • 10U
      • 1U
      • 2U
      • 3U
      • 4U
      • 5U
      • 5U (Full Tower)
      • 6U
      • 8U
      • Compact Mini-Tower
      • Fan-based Embedded
      • Fanless Embedded
      • Mid-Tower
      • Mini-1U
      • mini-tower
      • Tower
      • Tower or 5U
      • Еще
    • X12
      X12
      • 1U
      • 2U
      • 3U
      • 4U
      • 4U Tower
      • 8U
      • Fan-based Embedded
      • Fanless Embedded
      • Full-Tower
      • Mid-Tower
      • Mini-1U
      • Mini-ITX
      • mini-tower
      • Tower
      • Еще
    • X11
      X11
      • 10U
      • 1U
      • 2U
      • 3U
      • 4U
      • 7U
      • Mid-Tower
      • Mini-ITX
    • X10
      X10
      • 1U
      • 2U
      • 3U
      • 4U
      • 7U
      • Mid-Tower
      • Mini-ITX
    • H14
      H14
      • 10U
      • 1U
      • 2U
      • 4U
      • 5U
    • H13
      H13
      • 1U
      • 2U
      • 3U
      • 4U
      • 8U
      • Mid-Tower
      • Mini-Tower
    • H12
      H12
      • 1U
      • 2U
      • 4U
      • Mid-Tower
    0 Сравнение
    0 Избранное
    0 Корзина
    Blade Mid-Tower Mini-ITX
    super-micro.ru
    Каталог
    0 Сравнение
    0 Избранное
    0 Корзина
    super-micro.ru
    Телефоны
    +7 000 000-00-00
    Заказать звонок
    0
    0
    0
    super-micro.ru
    • +7 000 000-00-00
      • Назад
      • Телефоны
      • +7 000 000-00-00
      • Заказать звонок
    • info@super-micro.ru
    • г. Москва, ул. Пушкина 19
    • Пн. – Пт.: с 9:00 до 18:00
    • 0 Сравнение
    • 0 Избранное
    • 0 Корзина
    Главная
    X11
    1U
    SYS-6019P-WTR
    SYS-6019P-WTR
    SYS-6019P-WTR
    SYS-6019P-WTR
    SYS-6019P-WTR
    SYS-6019P-WTR
    SYS-6019P-WTR
    SYS-6019P-WTR
    SYS-6019P-WTR
    SYS-6019P-WTR
    SYS-6019P-WTR

    SuperServer 6019U-TN4R

    0
    Нет отзывов
    Арт. SYS-6019P-WTR

    Все характеристики    Все товары категории  
    Нашли дешевле?
    Информация о доставке
    • Характеристики
    • Документы
    • Отзывы
    • Оплата
    • Доставка
    Технические характеристики
    Motherboard Super X11DDW-L; Super X11DDW-L; Super X11DDW-L; Super X11DDW-L
    System Memory - Memory Capacity 12 DIMM slots Up to 3TB 3DS ECC DDR4-2933MHz † RDIMM/LRDIMM Supports Intel® Optane™ DCPMM ††
    System Memory - Memory Type 2933 † /2666/2400/2133MHz ECC DDR4 RDIMM/LRDIMM
    On-Board Devices - Chipset Intel® C621 chipset
    On-Board Devices - SATA SATA3 (6Gbps); RAID 0, 1, 5, 10
    On-Board Devices - IPMI Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support
    On-Board Devices - Network Controllers Dual LAN with Gigabit Ethernet from C621
    On-Board Devices - Video ASPEED AST2500 BMC
    Input Output - SATA 4 SATA3 (6 Gbps) ports
    Input Output - LAN 2 RJ45 Gigabit Ethernet ports 1 RJ45 Dedicated IPMI LAN port
    Input Output - USB 4 USB 3.0 ports (rear)
    Input Output - Video 1 VGA port
    PC Health Monitoring - FAN Fans with tachometer monitoring Status monitor for speed control Pulse Width Modulated (PWM) fan connectors
    PC Health Monitoring - Temperature Monitoring for CPU and chassis environment Thermal Control for fan connectors
    Chassis - Form Factor 1U Rackmount
    Chassis - Model CSE-815TQC-R706WB2
    Dimensions and Weight - Height 1.7" (43mm)
    Dimensions and Weight - Width 17.2" (437mm)
    Dimensions and Weight - Depth 25.6" (650mm)
    Dimensions and Weight - Available Colors Black
    Front Panel - Buttons Power On/Off button UID button
    Front Panel - LEDs Power status LED HDD activity LED Network activity LEDs Universal Information (UID) LED
    Expansion Slots - PCI-Express 2 PCI-E 3.0 x16 (FHHL) slots 1 PCI-E 3.0 x8 (LP) slot 1 PCI-E 3.0 x16 for Add-on-Module (AOM) 1 PCI-E 3.0 x4 NVMe M.2 slot (Both CPUs need to be installed for full access to PCI-E slots and onboard controllers. See manual block diagram and AOC Support for details.)
    Drive Bays - Hot-swap 4 Hot-swap 3.5" SATA3 drive bays
    Backplane SAS/SATA HDD Backplane; SAS/SATA HDD Backplane; SAS/SATA HDD Backplane; SAS/SATA HDD Backplane
    System Cooling - Fans 4 Counter-rotating 4cm PWM fans
    System BIOS - BIOS Type AMI 32Mb SPI Flash ROM
    Parts List - Items Included Part Number; Description; Motherboard / Chassis; MBD-X11DDW-L CSE-815TQC-R706WB2; Super X11DDW-L Motherboard 1U Chassis; Backplane; BPN-SAS3-815TQ; 1U 4-Port 12Gbps Backplane Support 4x3.5; Storage Cable; CBL-SAST-0388L-02; MINI SAS-4 SATA,INT,75/75/90/90CM,90CM SB,30AWG; Rubber Pad; MCP-150-00015-0B; Rubber pad, 3.0mm H, 10x10mm; Air Shroud; MCP-310-19019-0B; SC113/SC116/SC815/SC515, DP X11DDW Mylar air shroud; Air Block; MCP-320-00061-0B; CR foam for air block in SC113/SC116/SC815; Manual; MNL-1943-QRG; SYS-6019P-WT /WTR Quick Reference Guide,HF,RoHS; Riser Card (left); RSC-R1UW-2E16; 1U LHS WIO Riser card with two PCI-E x16 slots; Riser Card (right); RSC-R1UW-E8R; 1U RHS WIO Riser card with one PCI-E x8 slot; Heatsink w/ Retention; SNK-P0067PSMB; 1U Passive High Performance Front CPU Heat Sink w/ an 18-mm Wide Middle Air Channel for X11 Purley Platform Equipped w/ a Narrow Retention Mechanism/Bolster; * Power Supply; PWS-706P-1R; 1U 750W redundant power width 54.5mm(Platinum),HF,RoHS/REACH,PBF; * Power Cord; CBL-0160L; NEMA5-15P to C13 US power cord 16AWG 6ft, PBF (default for high watt); FAN-0156L4; 40x40x56 mm 13K-11K RPM Counter-rotating Fan,RoHS/REACH; * Rail Set; MCP-290-00054-0N; Rail set, quick/quick, optional for 1U 17.2"W SC815; Part Number; Description; Motherboard / Chassis; MBD-X11DDW-L CSE-815TQC-R706WB2; Super X11DDW-L Motherboard 1U Chassis; Backplane; BPN-SAS3-815TQ; 1U 4-Port 12Gbps Backplane Support 4x3.5; Storage Cable; CBL-SAST-0388L-02; MINI SAS-4 SATA,INT,75/75/90/90CM,90CM SB,30AWG; Rubber Pad; MCP-150-00015-0B; Rubber pad, 3.0mm H, 10x10mm; Air Shroud; MCP-310-19019-0B; SC113/SC116/SC815/SC515, DP X11DDW Mylar air shroud; Air Block; MCP-320-00061-0B; CR foam for air block in SC113/SC116/SC815; Manual; MNL-1943-QRG; SYS-6019P-WT /WTR Quick Reference Guide,HF,RoHS; Riser Card (left); RSC-R1UW-2E16; 1U LHS WIO Riser card with two PCI-E x16 slots; Riser Card (right); RSC-R1UW-E8R; 1U RHS WIO Riser card with one PCI-E x8 slot; Heatsink w/ Retention; SNK-P0067PSMB; 1U Passive High Performance Front CPU Heat Sink w/ an 18-mm Wide Middle Air Channel for X11 Purley Platform Equipped w/ a Narrow Retention Mechanism/Bolster; * Power Supply; PWS-706P-1R; 1U 750W redundant power width 54.5mm(Platinum),HF,RoHS/REACH,PBF; * Power Cord; CBL-0160L; NEMA5-15P to C13 US power cord 16AWG 6ft, PBF (default for high watt); FAN-0156L4; 40x40x56 mm 13K-11K RPM Counter-rotating Fan,RoHS/REACH; * Rail Set; MCP-290-00054-0N; Rail set, quick/quick, optional for 1U 17.2"W SC815; Part Number; Description; Motherboard / Chassis; MBD-X11DDW-L CSE-815TQC-R706WB2; Super X11DDW-L Motherboard 1U Chassis; Backplane; BPN-SAS3-815TQ; 1U 4-Port 12Gbps Backplane Support 4x3.5; Storage Cable; CBL-SAST-0388L-02; MINI SAS-4 SATA,INT,75/75/90/90CM,90CM SB,30AWG; Rubber Pad; MCP-150-00015-0B; Rubber pad, 3.0mm H, 10x10mm; Air Shroud; MCP-310-19019-0B; SC113/SC116/SC815/SC515, DP X11DDW Mylar air shroud; Air Block; MCP-320-00061-0B; CR foam for air block in SC113/SC116/SC815; Manual; MNL-1943-QRG; SYS-6019P-WT /WTR Quick Reference Guide,HF,RoHS; Riser Card (left); RSC-R1UW-2E16; 1U LHS WIO Riser card with two PCI-E x16 slots; Riser Card (right); RSC-R1UW-E8R; 1U RHS WIO Riser card with one PCI-E x8 slot; Heatsink w/ Retention; SNK-P0067PSMB; 1U Passive High Performance Front CPU Heat Sink w/ an 18-mm Wide Middle Air Channel for X11 Purley Platform Equipped w/ a Narrow Retention Mechanism/Bolster; * Power Supply; PWS-706P-1R; 1U 750W redundant power width 54.5mm(Platinum),HF,RoHS/REACH,PBF; * Power Cord; CBL-0160L; NEMA5-15P to C13 US power cord 16AWG 6ft, PBF (default for high watt); FAN-0156L4; 40x40x56 mm 13K-11K RPM Counter-rotating Fan,RoHS/REACH; * Rail Set; MCP-290-00054-0N; Rail set, quick/quick, optional for 1U 17.2"W SC815; Part Number; Description; Motherboard / Chassis; MBD-X11DDW-L CSE-815TQC-R706WB2; Super X11DDW-L Motherboard 1U Chassis; Backplane; BPN-SAS3-815TQ; 1U 4-Port 12Gbps Backplane Support 4x3.5; Storage Cable; CBL-SAST-0388L-02; MINI SAS-4 SATA,INT,75/75/90/90CM,90CM SB,30AWG; Rubber Pad; MCP-150-00015-0B; Rubber pad, 3.0mm H, 10x10mm; Air Shroud; MCP-310-19019-0B; SC113/SC116/SC815/SC515, DP X11DDW Mylar air shroud; Air Block; MCP-320-00061-0B; CR foam for air block in SC113/SC116/SC815; Manual; MNL-1943-QRG; SYS-6019P-WT /WTR Quick Reference Guide,HF,RoHS; Riser Card (left); RSC-R1UW-2E16; 1U LHS WIO Riser card with two PCI-E x16 slots; Riser Card (right); RSC-R1UW-E8R; 1U RHS WIO Riser card with one PCI-E x8 slot; Heatsink w/ Retention; SNK-P0067PSMB; 1U Passive High Performance Front CPU Heat Sink w/ an 18-mm Wide Middle Air Channel for X11 Purley Platform Equipped w/ a Narrow Retention Mechanism/Bolster; * Power Supply; PWS-706P-1R; 1U 750W redundant power width 54.5mm(Platinum),HF,RoHS/REACH,PBF; * Power Cord; CBL-0160L; NEMA5-15P to C13 US power cord 16AWG 6ft, PBF (default for high watt); FAN-0156L4; 40x40x56 mm 13K-11K RPM Counter-rotating Fan,RoHS/REACH; * Rail Set; MCP-290-00054-0N; Rail set, quick/quick, optional for 1U 17.2"W SC815
    Optional Parts List Part Number; Description; 3.5" to 2.5" Converter Tray; MCP-220-00043-0N; Black Hot-swap Gen-4 2.5" to 3.5" HDD tray; DVD-ROM / RW & Mounting Kit; DVM-HLDS-DVDRW-SBT2 & MCP-220-81502-0N; BLACK HLDS SLIM DVDRW SATA DRIVE Slim SATA DVD mounting kit; Internal 2.5" HDD Tray (FDD Slot); MCP-220-83601-0B; Black FDD dummy tray support 1x 2.5" slim HDD; Internal 2.5" HDD Tray (DVD Slot); MCP-290-00036-0B; Black DVD dummy tray support 1x 2.5" slim HDD; Cable for internal HDD; CBL-SAST-0624 CBL-0289L; SATA,INT,ROUND,ST-ST,70CM,30AWG Y split, big 4 pin to two RA SATA power extension 30cm, 20AWG; Add-on card for internal M.2 NVMe; AOC-SLG3-2M2; Low Profile PCI-E x8 add-on card supports 2 PCI-E 3.0 x4 M-Key M.2 NVMe Modules; Intel VROC RAID Key; AOC-VROCINTMOD AOC-VROCSTNMOD AOC-VROCPREMOD; Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only) Intel VROC Standard, RAID 0, 1, 10 Intel VROC Premium, RAID 0, 1, 5, 10; Additional Fan; FAN-0156L4; 40x40x56 mm 13K-11K RPM Counter-rotating Fan; Storage Controller Card(s) & Cables(s); AOC-S3908L-H8IR-16DD & 1x CBL-SAST-1275A-100 AOC-S3808L-L8iT & 1x CBL-SAST-1275A-100 AOM-S3108M-H8 & 1x CBL-SAST-0699 & 1x FAN-0156L4 AOC-S3108L-H8IR-16DD & 1x CBL-SAST-0699 AOC-S3008L-L8i & 1x CBL-SAST-0699 AOC-S3008L-L8e & 1x CBL-SAST-0699; Standard LP, 8 internal ports (12Gb/s) Gen-4, 122HDD; RAID 0, 1, 5, 6, 10, 50, 60; 80cm Slimline to 4 SATA Cable Standard LP, 8 internal ports (12Gb/s) Gen-4, 16HDD; HBA; 80cm Slimline to 4 SATA Cable Supermicro LP, 8 internal ports (12Gb/s) SAS Mezzanine; RAID 0, 1, 5, 6, 10, 50, 60; 40x40x56 mm 13K-11K RPM Counter-rotating Fan Standard LP, 8 internal ports (12Gb/s) Gen-3, 16HDD; RAID 0, 1, 5, 6, 10, 50, 60 Standard LP, 8 internal ports (12Gb/s) Gen-3, 63HDD; RAID 0, 1, 10 Standard LP, 8 internal ports (12Gb/s) Gen-3, 122HDD; HBA; CacheVault (for 3108); BTR-CV3108-1U1 BTR-TFM8G-LSICVM02 & BKT-BBU-BRACKET-05 BTR-TFM8G-LSICVM02 & MCP-240-00127-0N; CacheVault for Broadcom 3108 with SuperCap mounting in 1U 40x56 fan tray CacheVault for Broadcom 3108; SuperCap mounting bracket for PCI-E location CacheVault for Broadcom 3108; SuperCap mounting bracket for 2.5" HDD location; CacheVault (for 3908/3916); BTR-CVPM05 & BKT-BBU-BRACKET-05/MCP-240-00127-0N BTR-CVPM05 & MCP-240-00203-0N; CacheVault for Broadcom 3908/3916; SuperCap mounting bracket for PCI-E location CacheVault for Broadcom 3908/3916; SuperCap mounting bracket for 2.5" HDD location; Network Card(s); AOC-SGP-i2 AOC-SGP-i4 AOC-STGS-i1T AOC-STGS-i2T AOC-STG-i4T AOC-STGN-i1S AOC-STGN-i2S AOC-STG-i4S AOC-S25G-i2S AOC-MCX555A-ECAT AOC-MCX556A-ECAT; Standard LP, 2x GbE RJ45, PCI-E x4, Intel® i350AM2 Standard LP, 4x GbE RJ45, PCI-E x4, Intel® i350AM4 Standard LP, 1x 10GbE RJ45, PCI-E x4, Intel® X550-AT Standard LP, 2x 10GbE RJ45, PCI-E x4, Intel® X550-AT2 Standard LP, 4x 10GBE RJ45, PCI-E x8, Intel® XL710-BM1 Standard LP, 1x 10GbE SFP+, PCI-E x8, Intel® 82599EN Standard LP, 2x 10GbE SFP+, PCI-E x8, Intel® 82599ES Standard LP, 4x 10GbE SFP+, PCI-E x8, Intel® XL710-BM1 Standard LP, 2x 25GbE SFP28, PCI-E x8, Intel® XXV710 + Marvell Unionville Standard LP, 1x 100GbE (and EDR IB) QSFP28, PCI-E x16, Mellanox® ConnectX-5 Standard LP, 2x 100GbE (and EDR IB) QSFP28, PCI-E x16, Mellanox® ConnectX-5; Front Bezel; CSE-PTFB-813-02 CSE-PTFB-813-02B; Front Bezel w/ Round Venting Holes Black Front Bezel w/ Round Venting Holes; Cable Management Arm; MCP-290-00085-0N; Supermicro Cable Management Arm for 1U Chassis; Inlet Thermal Sensor; MCP-280-00033-0N; Universal Thermal sensor kit with 80cm I2C cable; TPM security module (optional, not included); AOM-TPM-9670V-S AOM-TPM-9671V-S; SPI capable TPM 2.0 with Infineon 9670 controller; vertical form factor SPI capable TPM 1.2 with Infineon 9670 controller; vertical form factor; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; 3.5" to 2.5" Converter Tray; MCP-220-00043-0N; Black Hot-swap Gen-4 2.5" to 3.5" HDD tray; DVD-ROM / RW & Mounting Kit; DVM-HLDS-DVDRW-SBT2 & MCP-220-81502-0N; BLACK HLDS SLIM DVDRW SATA DRIVE Slim SATA DVD mounting kit; Internal 2.5" HDD Tray (FDD Slot); MCP-220-83601-0B; Black FDD dummy tray support 1x 2.5" slim HDD; Internal 2.5" HDD Tray (DVD Slot); MCP-290-00036-0B; Black DVD dummy tray support 1x 2.5" slim HDD; Cable for internal HDD; CBL-SAST-0624 CBL-0289L; SATA,INT,ROUND,ST-ST,70CM,30AWG Y split, big 4 pin to two RA SATA power extension 30cm, 20AWG; Add-on card for internal M.2 NVMe; AOC-SLG3-2M2; Low Profile PCI-E x8 add-on card supports 2 PCI-E 3.0 x4 M-Key M.2 NVMe Modules; Intel VROC RAID Key; AOC-VROCINTMOD AOC-VROCSTNMOD AOC-VROCPREMOD; Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only) Intel VROC Standard, RAID 0, 1, 10 Intel VROC Premium, RAID 0, 1, 5, 10; Additional Fan; FAN-0156L4; 40x40x56 mm 13K-11K RPM Counter-rotating Fan; Storage Controller Card(s) & Cables(s); AOC-S3908L-H8IR-16DD & 1x CBL-SAST-1275A-100 AOC-S3808L-L8iT & 1x CBL-SAST-1275A-100 AOM-S3108M-H8 & 1x CBL-SAST-0699 & 1x FAN-0156L4 AOC-S3108L-H8IR-16DD & 1x CBL-SAST-0699 AOC-S3008L-L8i & 1x CBL-SAST-0699 AOC-S3008L-L8e & 1x CBL-SAST-0699; Standard LP, 8 internal ports (12Gb/s) Gen-4, 122HDD; RAID 0, 1, 5, 6, 10, 50, 60; 80cm Slimline to 4 SATA Cable Standard LP, 8 internal ports (12Gb/s) Gen-4, 16HDD; HBA; 80cm Slimline to 4 SATA Cable Supermicro LP, 8 internal ports (12Gb/s) SAS Mezzanine; RAID 0, 1, 5, 6, 10, 50, 60; 40x40x56 mm 13K-11K RPM Counter-rotating Fan Standard LP, 8 internal ports (12Gb/s) Gen-3, 16HDD; RAID 0, 1, 5, 6, 10, 50, 60 Standard LP, 8 internal ports (12Gb/s) Gen-3, 63HDD; RAID 0, 1, 10 Standard LP, 8 internal ports (12Gb/s) Gen-3, 122HDD; HBA; CacheVault (for 3108); BTR-CV3108-1U1 BTR-TFM8G-LSICVM02 & BKT-BBU-BRACKET-05 BTR-TFM8G-LSICVM02 & MCP-240-00127-0N; CacheVault for Broadcom 3108 with SuperCap mounting in 1U 40x56 fan tray CacheVault for Broadcom 3108; SuperCap mounting bracket for PCI-E location CacheVault for Broadcom 3108; SuperCap mounting bracket for 2.5" HDD location; CacheVault (for 3908/3916); BTR-CVPM05 & BKT-BBU-BRACKET-05/MCP-240-00127-0N BTR-CVPM05 & MCP-240-00203-0N; CacheVault for Broadcom 3908/3916; SuperCap mounting bracket for PCI-E location CacheVault for Broadcom 3908/3916; SuperCap mounting bracket for 2.5" HDD location; Network Card(s); AOC-SGP-i2 AOC-SGP-i4 AOC-STGS-i1T AOC-STGS-i2T AOC-STG-i4T AOC-STGN-i1S AOC-STGN-i2S AOC-STG-i4S AOC-S25G-i2S AOC-MCX555A-ECAT AOC-MCX556A-ECAT; Standard LP, 2x GbE RJ45, PCI-E x4, Intel® i350AM2 Standard LP, 4x GbE RJ45, PCI-E x4, Intel® i350AM4 Standard LP, 1x 10GbE RJ45, PCI-E x4, Intel® X550-AT Standard LP, 2x 10GbE RJ45, PCI-E x4, Intel® X550-AT2 Standard LP, 4x 10GBE RJ45, PCI-E x8, Intel® XL710-BM1 Standard LP, 1x 10GbE SFP+, PCI-E x8, Intel® 82599EN Standard LP, 2x 10GbE SFP+, PCI-E x8, Intel® 82599ES Standard LP, 4x 10GbE SFP+, PCI-E x8, Intel® XL710-BM1 Standard LP, 2x 25GbE SFP28, PCI-E x8, Intel® XXV710 + Marvell Unionville Standard LP, 1x 100GbE (and EDR IB) QSFP28, PCI-E x16, Mellanox® ConnectX-5 Standard LP, 2x 100GbE (and EDR IB) QSFP28, PCI-E x16, Mellanox® ConnectX-5; Front Bezel; CSE-PTFB-813-02 CSE-PTFB-813-02B; Front Bezel w/ Round Venting Holes Black Front Bezel w/ Round Venting Holes; Cable Management Arm; MCP-290-00085-0N; Supermicro Cable Management Arm for 1U Chassis; Inlet Thermal Sensor; MCP-280-00033-0N; Universal Thermal sensor kit with 80cm I2C cable; TPM security module (optional, not included); AOM-TPM-9670V-S AOM-TPM-9671V-S; SPI capable TPM 2.0 with Infineon 9670 controller; vertical form factor SPI capable TPM 1.2 with Infineon 9670 controller; vertical form factor; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; 3.5" to 2.5" Converter Tray; MCP-220-00043-0N; Black Hot-swap Gen-4 2.5" to 3.5" HDD tray; DVD-ROM / RW & Mounting Kit; DVM-HLDS-DVDRW-SBT2 & MCP-220-81502-0N; BLACK HLDS SLIM DVDRW SATA DRIVE Slim SATA DVD mounting kit; Internal 2.5" HDD Tray (FDD Slot); MCP-220-83601-0B; Black FDD dummy tray support 1x 2.5" slim HDD; Internal 2.5" HDD Tray (DVD Slot); MCP-290-00036-0B; Black DVD dummy tray support 1x 2.5" slim HDD; Cable for internal HDD; CBL-SAST-0624 CBL-0289L; SATA,INT,ROUND,ST-ST,70CM,30AWG Y split, big 4 pin to two RA SATA power extension 30cm, 20AWG; Add-on card for internal M.2 NVMe; AOC-SLG3-2M2; Low Profile PCI-E x8 add-on card supports 2 PCI-E 3.0 x4 M-Key M.2 NVMe Modules; Intel VROC RAID Key; AOC-VROCINTMOD AOC-VROCSTNMOD AOC-VROCPREMOD; Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only) Intel VROC Standard, RAID 0, 1, 10 Intel VROC Premium, RAID 0, 1, 5, 10; Additional Fan; FAN-0156L4; 40x40x56 mm 13K-11K RPM Counter-rotating Fan; Storage Controller Card(s) & Cables(s); AOC-S3908L-H8IR-16DD & 1x CBL-SAST-1275A-100 AOC-S3808L-L8iT & 1x CBL-SAST-1275A-100 AOM-S3108M-H8 & 1x CBL-SAST-0699 & 1x FAN-0156L4 AOC-S3108L-H8IR-16DD & 1x CBL-SAST-0699 AOC-S3008L-L8i & 1x CBL-SAST-0699 AOC-S3008L-L8e & 1x CBL-SAST-0699; Standard LP, 8 internal ports (12Gb/s) Gen-4, 122HDD; RAID 0, 1, 5, 6, 10, 50, 60; 80cm Slimline to 4 SATA Cable Standard LP, 8 internal ports (12Gb/s) Gen-4, 16HDD; HBA; 80cm Slimline to 4 SATA Cable Supermicro LP, 8 internal ports (12Gb/s) SAS Mezzanine; RAID 0, 1, 5, 6, 10, 50, 60; 40x40x56 mm 13K-11K RPM Counter-rotating Fan Standard LP, 8 internal ports (12Gb/s) Gen-3, 16HDD; RAID 0, 1, 5, 6, 10, 50, 60 Standard LP, 8 internal ports (12Gb/s) Gen-3, 63HDD; RAID 0, 1, 10 Standard LP, 8 internal ports (12Gb/s) Gen-3, 122HDD; HBA; CacheVault (for 3108); BTR-CV3108-1U1 BTR-TFM8G-LSICVM02 & BKT-BBU-BRACKET-05 BTR-TFM8G-LSICVM02 & MCP-240-00127-0N; CacheVault for Broadcom 3108 with SuperCap mounting in 1U 40x56 fan tray CacheVault for Broadcom 3108; SuperCap mounting bracket for PCI-E location CacheVault for Broadcom 3108; SuperCap mounting bracket for 2.5" HDD location; CacheVault (for 3908/3916); BTR-CVPM05 & BKT-BBU-BRACKET-05/MCP-240-00127-0N BTR-CVPM05 & MCP-240-00203-0N; CacheVault for Broadcom 3908/3916; SuperCap mounting bracket for PCI-E location CacheVault for Broadcom 3908/3916; SuperCap mounting bracket for 2.5" HDD location; Network Card(s); AOC-SGP-i2 AOC-SGP-i4 AOC-STGS-i1T AOC-STGS-i2T AOC-STG-i4T AOC-STGN-i1S AOC-STGN-i2S AOC-STG-i4S AOC-S25G-i2S AOC-MCX555A-ECAT AOC-MCX556A-ECAT; Standard LP, 2x GbE RJ45, PCI-E x4, Intel® i350AM2 Standard LP, 4x GbE RJ45, PCI-E x4, Intel® i350AM4 Standard LP, 1x 10GbE RJ45, PCI-E x4, Intel® X550-AT Standard LP, 2x 10GbE RJ45, PCI-E x4, Intel® X550-AT2 Standard LP, 4x 10GBE RJ45, PCI-E x8, Intel® XL710-BM1 Standard LP, 1x 10GbE SFP+, PCI-E x8, Intel® 82599EN Standard LP, 2x 10GbE SFP+, PCI-E x8, Intel® 82599ES Standard LP, 4x 10GbE SFP+, PCI-E x8, Intel® XL710-BM1 Standard LP, 2x 25GbE SFP28, PCI-E x8, Intel® XXV710 + Marvell Unionville Standard LP, 1x 100GbE (and EDR IB) QSFP28, PCI-E x16, Mellanox® ConnectX-5 Standard LP, 2x 100GbE (and EDR IB) QSFP28, PCI-E x16, Mellanox® ConnectX-5; Front Bezel; CSE-PTFB-813-02 CSE-PTFB-813-02B; Front Bezel w/ Round Venting Holes Black Front Bezel w/ Round Venting Holes; Cable Management Arm; MCP-290-00085-0N; Supermicro Cable Management Arm for 1U Chassis; Inlet Thermal Sensor; MCP-280-00033-0N; Universal Thermal sensor kit with 80cm I2C cable; TPM security module (optional, not included); AOM-TPM-9670V-S AOM-TPM-9671V-S; SPI capable TPM 2.0 with Infineon 9670 controller; vertical form factor SPI capable TPM 1.2 with Infineon 9670 controller; vertical form factor; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; 3.5" to 2.5" Converter Tray; MCP-220-00043-0N; Black Hot-swap Gen-4 2.5" to 3.5" HDD tray; DVD-ROM / RW & Mounting Kit; DVM-HLDS-DVDRW-SBT2 & MCP-220-81502-0N; BLACK HLDS SLIM DVDRW SATA DRIVE Slim SATA DVD mounting kit; Internal 2.5" HDD Tray (FDD Slot); MCP-220-83601-0B; Black FDD dummy tray support 1x 2.5" slim HDD; Internal 2.5" HDD Tray (DVD Slot); MCP-290-00036-0B; Black DVD dummy tray support 1x 2.5" slim HDD; Cable for internal HDD; CBL-SAST-0624 CBL-0289L; SATA,INT,ROUND,ST-ST,70CM,30AWG Y split, big 4 pin to two RA SATA power extension 30cm, 20AWG; Add-on card for internal M.2 NVMe; AOC-SLG3-2M2; Low Profile PCI-E x8 add-on card supports 2 PCI-E 3.0 x4 M-Key M.2 NVMe Modules; Intel VROC RAID Key; AOC-VROCINTMOD AOC-VROCSTNMOD AOC-VROCPREMOD; Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only) Intel VROC Standard, RAID 0, 1, 10 Intel VROC Premium, RAID 0, 1, 5, 10; Additional Fan; FAN-0156L4; 40x40x56 mm 13K-11K RPM Counter-rotating Fan; Storage Controller Card(s) & Cables(s); AOC-S3908L-H8IR-16DD & 1x CBL-SAST-1275A-100 AOC-S3808L-L8iT & 1x CBL-SAST-1275A-100 AOM-S3108M-H8 & 1x CBL-SAST-0699 & 1x FAN-0156L4 AOC-S3108L-H8IR-16DD & 1x CBL-SAST-0699 AOC-S3008L-L8i & 1x CBL-SAST-0699 AOC-S3008L-L8e & 1x CBL-SAST-0699; Standard LP, 8 internal ports (12Gb/s) Gen-4, 122HDD; RAID 0, 1, 5, 6, 10, 50, 60; 80cm Slimline to 4 SATA Cable Standard LP, 8 internal ports (12Gb/s) Gen-4, 16HDD; HBA; 80cm Slimline to 4 SATA Cable Supermicro LP, 8 internal ports (12Gb/s) SAS Mezzanine; RAID 0, 1, 5, 6, 10, 50, 60; 40x40x56 mm 13K-11K RPM Counter-rotating Fan Standard LP, 8 internal ports (12Gb/s) Gen-3, 16HDD; RAID 0, 1, 5, 6, 10, 50, 60 Standard LP, 8 internal ports (12Gb/s) Gen-3, 63HDD; RAID 0, 1, 10 Standard LP, 8 internal ports (12Gb/s) Gen-3, 122HDD; HBA; CacheVault (for 3108); BTR-CV3108-1U1 BTR-TFM8G-LSICVM02 & BKT-BBU-BRACKET-05 BTR-TFM8G-LSICVM02 & MCP-240-00127-0N; CacheVault for Broadcom 3108 with SuperCap mounting in 1U 40x56 fan tray CacheVault for Broadcom 3108; SuperCap mounting bracket for PCI-E location CacheVault for Broadcom 3108; SuperCap mounting bracket for 2.5" HDD location; CacheVault (for 3908/3916); BTR-CVPM05 & BKT-BBU-BRACKET-05/MCP-240-00127-0N BTR-CVPM05 & MCP-240-00203-0N; CacheVault for Broadcom 3908/3916; SuperCap mounting bracket for PCI-E location CacheVault for Broadcom 3908/3916; SuperCap mounting bracket for 2.5" HDD location; Network Card(s); AOC-SGP-i2 AOC-SGP-i4 AOC-STGS-i1T AOC-STGS-i2T AOC-STG-i4T AOC-STGN-i1S AOC-STGN-i2S AOC-STG-i4S AOC-S25G-i2S AOC-MCX555A-ECAT AOC-MCX556A-ECAT; Standard LP, 2x GbE RJ45, PCI-E x4, Intel® i350AM2 Standard LP, 4x GbE RJ45, PCI-E x4, Intel® i350AM4 Standard LP, 1x 10GbE RJ45, PCI-E x4, Intel® X550-AT Standard LP, 2x 10GbE RJ45, PCI-E x4, Intel® X550-AT2 Standard LP, 4x 10GBE RJ45, PCI-E x8, Intel® XL710-BM1 Standard LP, 1x 10GbE SFP+, PCI-E x8, Intel® 82599EN Standard LP, 2x 10GbE SFP+, PCI-E x8, Intel® 82599ES Standard LP, 4x 10GbE SFP+, PCI-E x8, Intel® XL710-BM1 Standard LP, 2x 25GbE SFP28, PCI-E x8, Intel® XXV710 + Marvell Unionville Standard LP, 1x 100GbE (and EDR IB) QSFP28, PCI-E x16, Mellanox® ConnectX-5 Standard LP, 2x 100GbE (and EDR IB) QSFP28, PCI-E x16, Mellanox® ConnectX-5; Front Bezel; CSE-PTFB-813-02 CSE-PTFB-813-02B; Front Bezel w/ Round Venting Holes Black Front Bezel w/ Round Venting Holes; Cable Management Arm; MCP-290-00085-0N; Supermicro Cable Management Arm for 1U Chassis; Inlet Thermal Sensor; MCP-280-00033-0N; Universal Thermal sensor kit with 80cm I2C cable; TPM security module (optional, not included); AOM-TPM-9670V-S AOM-TPM-9671V-S; SPI capable TPM 2.0 with Infineon 9670 controller; vertical form factor SPI capable TPM 1.2 with Infineon 9670 controller; vertical form factor; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license)
    ProcessorCache - CPU Dual Socket P (LGA 3647) 2nd Gen Intel® Xeon® Scalable Processors and Intel® Xeon® Scalable Processors ‡ , Dual UPI up to 10.4GT/s Support CPU TDP 70-165W *
    ProcessorCache - Note ‡ BIOS version 3.2 or above is required to support 2nd Gen Intel® Xeon® Scalable processors (codenamed Cascade Lake-R). Extended thermal solutions may be required to support CPUs higher than 165W TDP, please contact Supermicro Technical Support for additional information.
    Management - Software Intel® Node Manager IPMI 2.0 KVM with dedicated LAN SSM , SPM , SUM SuperDoctor® 5 Watch Dog
    Management - Power Configurations ACPI / APM Power Management
    Input Output - DOM 2 Super DOM (Disk on Module) ports
    PC Health Monitoring - CPU Monitors for CPU Cores, Chipset Voltages, Memory. 4+1 Phase-switching voltage regulator
    Dimensions and Weight - Gross Weight 46 lbs (20.9kg)
    System Memory - Note † 2933MHz in two DIMMs per channel can be achieved by using memory purchased from Supermicro †† Cascade Lake only. Contact your Supermicro sales rep for more info.
    Operating Environment - RoHS RoHS Compliant
    Operating Environment - Environmental Spec Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F) Non-operating Temperature: -40°C to 60°C (-40°F to 140°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing)
    ACDC240V Input Redundant Power Supply 700W/750W Redundant Power Supplies with PMBus; 700W/750W Redundant Power Supplies with PMBus; 700W/750W Redundant Power Supplies with PMBus; 700W/750W Redundant Power Supplies with PMBus
    ACDC240V Input Redundant Power Supply - Total Output Power 700W/750W
    ACDC240V Input Redundant Power Supply - DimensionW x H x L 54.5 x 40.25 x 320 mm
    ACDC240V Input Redundant Power Supply - Input 100 - 140Vac / 8 - 6A / 50-60Hz 200 - 240Vac / 4.5 - 3.8A / 50-60Hz 200 - 240Vdc / 4.5 - 3.8A (CCC Only)
    ACDC240V Input Redundant Power Supply - 12V Max: 58A / Min: 0.5A (100 - 140Vac) Max: 62A / Min: 0.5A (200 - 240Vac) Max: 62A / Min: 0.5A (200 - 240Vdc) (CB/CCC Only)
    ACDC240V Input Redundant Power Supply - 5V sb Max: 3A / Min: 0A
    ACDC240V Input Redundant Power Supply - Output Type Gold Finger Connector Mating with Molex 45984-4343
    ACDC240V Input Redundant Power Supply - Certification Platinum Certified [ Test Report ]
    ProcessorCache - Cores Up to 28 Cores
    Product SKUs - SYS-6019P-WTR SuperServer 6019P-WTR ( Black )
    MNL-1943
    9,9 Мб
    datasheet_H12_2U2NodeGPU
    999,9 Кб
    Отзывы
    Загрузка отзывов...
    Нет отзывов
    Добавить отзыв

    Оплачивайте покупки удобным способом. В интернет-магазине доступно 3 варианта оплаты:

    1. Наличные при самовывозе или доставке курьером. Специалист свяжется с вами в день доставки, чтобы уточнить время и заранее подготовить сдачу с любой купюры. Вы подписываете товаросопроводительные документы, вносите денежные средства, получаете товар и чек.
    2. Безналичный расчет при самовывозе или оформлении в интернет-магазине: карты МИР, Visa и MasterCard. Чтобы оплатить покупку, система перенаправит вас на сервер системы ASSIST. Здесь нужно ввести номер карты, срок действия и имя держателя.
    3. ЮMoney при онлайн-заказе. Для совершения покупки система перенаправит вас на страницу платежного сервиса. Здесь необходимо заполнить форму по инструкции.

    Экономьте время на получении заказа. В интернет-магазине доступно 4 варианта доставки:

    1. Курьерская доставка работает с 9.00 до 19.00. Когда товар поступит на склад, курьерская служба свяжется для уточнения деталей. Специалист предложит выбрать удобное время доставки и уточнит адрес. Осмотрите упаковку на целостность и соответствие указанной комплектации.
    2. Самовывоз из магазина. Список торговых точек для выбора появится в корзине. Когда заказ поступит на склад, вам придет уведомление. Для получения заказа обратитесь к сотруднику в кассовой зоне и назовите номер.
    3. Постамат. Когда заказ поступит на точку, на ваш телефон или e-mail придет уникальный код. Заказ нужно оплатить в терминале постамата. Срок хранения — 3 дня.
    4. Почтовая доставка через почту России. Когда заказ придет в отделение, на ваш адрес придет извещение о посылке. Перед оплатой вы можете оценить состояние коробки: вес, целостность. Вскрывать коробку самостоятельно вы можете только после оплаты заказа. Один заказ может содержать не больше 10 позиций и его стоимость не должна превышать 100 000 р.
    Назад к списку
    Конфиденциальность Оферта
    © 2025 Super-Micro.ru
    Главная Каталог 0 Корзина 0 Избранные 0 Сравнение Акции Контакты Услуги Бренды Отзывы Компания Лицензии Документы Реквизиты Поиск Блог Обзоры