| Motherboard | Super X11DPT-B; Super X11DPT-B; Super X11DPT-B; Super X11DPT-B |
| Processor - CPU | Dual Socket P (LGA 3647) 2nd Gen Intel® Xeon® Scalable Processors and Intel® Xeon® Scalable Processors ‡ , Dual UPI up to 10.4GT/s Support CPU TDP 70-205W * |
| Processor - Note | ‡ BIOS version 3.2 or above is required to support 2nd Gen Intel® Xeon® Scalable processors (codenamed Cascade Lake-R) |
| System Memory - Memory Capacity | 24 DIMM slots Up to 6TB 3DS ECC DDR4-2933MHz † RDIMM/LRDIMM Supports Intel® Optane™ DCPMM †† |
| System Memory - Memory Type | 2933 † /2666/2400/2133MHz ECC DDR4 RDIMM/LRDIMM |
| On-Board Devices - Chipset | Intel® C621 chipset |
| On-Board Devices - IPMI | Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support |
| On-Board Devices - Video | ASPEED AST2500 BMC |
| PC Health Monitoring - FAN | Fans with tachometer monitoring Status monitor for speed control Pulse Width Modulated (PWM) fan connectors |
| PC Health Monitoring - Temperature | Monitoring for CPU and chassis environment Thermal Control for fan connectors |
| Chassis - Form Factor | 2U Rackmount |
| Chassis - Model | CSE-827BHD+-R2K22BP |
| Dimensions and Weight - Height | 3.47" (88mm) |
| Dimensions and Weight - Width | 17.6" (447mm) |
| Dimensions and Weight - Depth | 30.11" (765mm) |
| Dimensions and Weight - Package | 9.76" (H) x 24.65" (W) x 45.28" (D) |
| Dimensions and Weight - Weight | Gross Weight: 114.66 lbs (52.01 kg) Net Weight: 87.13 lbs (39.52 kg) |
| Dimensions and Weight - Available Colors | Black |
| Front Panel - Buttons | Power On/Off button UID button |
| Front Panel - LEDs | Power status LED HDD activity LED Network activity LEDs Universal Information (UID) LED |
| System Cooling - Fans | 4 Heavy duty 8cm PWM fans with air shroud |
| Power Supply | 2200W Redundant Power Supplies with PMBus; 2200W Redundant Power Supplies with PMBus; 2200W Redundant Power Supplies with PMBus; 2200W Redundant Power Supplies with PMBus |
| Power Supply - 12V | Max: 100A / Min: 0A (100-127Vac) Max: 150A / Min: 0A (200-220Vac) Max: 165A / Min: 0A (220-230Vac) Max: 174.17A / Min: 0A (230-240Vac) Max: 174.17A / Min: 0A (180-220Vac, UL/cUL only) Max: 183.33A / Min: 0A (220-240Vac, UL/cUL only) Max: 174.17A / Min: 0A (230-240Vdc, CCC only) |
| Power Supply - Certification | Titanium Level [ Test Report ] |
| System BIOS - BIOS Type | AMI 32Mb SPI Flash ROM |
| Parts List - Items Included | Part Number; Description; Motherboard / Chassis; MBD-X11DPT-B CSE-827BHD+-R2K22BP; Super X11DPT-B Motherboard 2U Chassis; Backplane; BPN-ADP-6S3008N3-2UB; Big Twin 2U Hybrid ADPHDD: 2x SAS3 port + 3 NVMe or SAS3 ports (SAS3008 controller)M.2: 2x SATA or PCIe M.2 ports,HF,RoHS; Backplane; BPN-SAS3-827BHQ-N3; 2U 12-Port 4-Node Hybrid Backplane Supports 3x3.5; Cable 1; CBL-PWCD-0578; PWCD,US,IEC60320 C14 TO C13,3FT,14AWG; Drive Tray(s); MCP-220-00133-0B-BULK; Black gen 8 hot-swap 3.5; MCP-240-82718-0N; SC827B BigTwin type I (Impact) BPN retention bkt assy; Air Shroud; MCP-310-21725-0B; Bigtwin 2U2N plastic air shroud for Cascade lake MB; Manual; MNL-2091-QRG; 6029BT-DNC0R Quick Reference Guide; Riser Card; RSC-P2-88; 2U LHS TwinPro Riser card with two standard PCI-E x8 slots,H; Heatsink / Retention; SNK-P0068PS; 2U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Heatsink / Retention; SNK-P0069PS; 1.5U Proprietary 50-mm Tall Front Passive CPU Heat Sink for X11 Purley Platform 2U Node Twin Series Servers; FAN-0162L4; 80x80x38 mm, 13.5K RPM, HCP, LMV, and LPC Cooling Fan; Power Supply; PWS-2K22A-1R; 1U 2200W Redundant Power Supply Titanium, 45(W) X 40(H) X 48; Part Number; Description; Motherboard / Chassis; MBD-X11DPT-B CSE-827BHD+-R2K22BP; Super X11DPT-B Motherboard 2U Chassis; Backplane; BPN-ADP-6S3008N3-2UB; Big Twin 2U Hybrid ADPHDD: 2x SAS3 port + 3 NVMe or SAS3 ports (SAS3008 controller)M.2: 2x SATA or PCIe M.2 ports,HF,RoHS; Backplane; BPN-SAS3-827BHQ-N3; 2U 12-Port 4-Node Hybrid Backplane Supports 3x3.5; Cable 1; CBL-PWCD-0578; PWCD,US,IEC60320 C14 TO C13,3FT,14AWG; Drive Tray(s); MCP-220-00133-0B-BULK; Black gen 8 hot-swap 3.5; MCP-240-82718-0N; SC827B BigTwin type I (Impact) BPN retention bkt assy; Air Shroud; MCP-310-21725-0B; Bigtwin 2U2N plastic air shroud for Cascade lake MB; Manual; MNL-2091-QRG; 6029BT-DNC0R Quick Reference Guide; Riser Card; RSC-P2-88; 2U LHS TwinPro Riser card with two standard PCI-E x8 slots,H; Heatsink / Retention; SNK-P0068PS; 2U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Heatsink / Retention; SNK-P0069PS; 1.5U Proprietary 50-mm Tall Front Passive CPU Heat Sink for X11 Purley Platform 2U Node Twin Series Servers; FAN-0162L4; 80x80x38 mm, 13.5K RPM, HCP, LMV, and LPC Cooling Fan; Power Supply; PWS-2K22A-1R; 1U 2200W Redundant Power Supply Titanium, 45(W) X 40(H) X 48; Part Number; Description; Motherboard / Chassis; MBD-X11DPT-B CSE-827BHD+-R2K22BP; Super X11DPT-B Motherboard 2U Chassis; Backplane; BPN-ADP-6S3008N3-2UB; Big Twin 2U Hybrid ADPHDD: 2x SAS3 port + 3 NVMe or SAS3 ports (SAS3008 controller)M.2: 2x SATA or PCIe M.2 ports,HF,RoHS; Backplane; BPN-SAS3-827BHQ-N3; 2U 12-Port 4-Node Hybrid Backplane Supports 3x3.5; Cable 1; CBL-PWCD-0578; PWCD,US,IEC60320 C14 TO C13,3FT,14AWG; Drive Tray(s); MCP-220-00133-0B-BULK; Black gen 8 hot-swap 3.5; MCP-240-82718-0N; SC827B BigTwin type I (Impact) BPN retention bkt assy; Air Shroud; MCP-310-21725-0B; Bigtwin 2U2N plastic air shroud for Cascade lake MB; Manual; MNL-2091-QRG; 6029BT-DNC0R Quick Reference Guide; Riser Card; RSC-P2-88; 2U LHS TwinPro Riser card with two standard PCI-E x8 slots,H; Heatsink / Retention; SNK-P0068PS; 2U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Heatsink / Retention; SNK-P0069PS; 1.5U Proprietary 50-mm Tall Front Passive CPU Heat Sink for X11 Purley Platform 2U Node Twin Series Servers; FAN-0162L4; 80x80x38 mm, 13.5K RPM, HCP, LMV, and LPC Cooling Fan; Power Supply; PWS-2K22A-1R; 1U 2200W Redundant Power Supply Titanium, 45(W) X 40(H) X 48; Part Number; Description; Motherboard / Chassis; MBD-X11DPT-B CSE-827BHD+-R2K22BP; Super X11DPT-B Motherboard 2U Chassis; Backplane; BPN-ADP-6S3008N3-2UB; Big Twin 2U Hybrid ADPHDD: 2x SAS3 port + 3 NVMe or SAS3 ports (SAS3008 controller)M.2: 2x SATA or PCIe M.2 ports,HF,RoHS; Backplane; BPN-SAS3-827BHQ-N3; 2U 12-Port 4-Node Hybrid Backplane Supports 3x3.5; Cable 1; CBL-PWCD-0578; PWCD,US,IEC60320 C14 TO C13,3FT,14AWG; Drive Tray(s); MCP-220-00133-0B-BULK; Black gen 8 hot-swap 3.5; MCP-240-82718-0N; SC827B BigTwin type I (Impact) BPN retention bkt assy; Air Shroud; MCP-310-21725-0B; Bigtwin 2U2N plastic air shroud for Cascade lake MB; Manual; MNL-2091-QRG; 6029BT-DNC0R Quick Reference Guide; Riser Card; RSC-P2-88; 2U LHS TwinPro Riser card with two standard PCI-E x8 slots,H; Heatsink / Retention; SNK-P0068PS; 2U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Heatsink / Retention; SNK-P0069PS; 1.5U Proprietary 50-mm Tall Front Passive CPU Heat Sink for X11 Purley Platform 2U Node Twin Series Servers; FAN-0162L4; 80x80x38 mm, 13.5K RPM, HCP, LMV, and LPC Cooling Fan; Power Supply; PWS-2K22A-1R; 1U 2200W Redundant Power Supply Titanium, 45(W) X 40(H) X 48 |
| Optional Parts List | Part Number; Description; FAN-0191L4; 80x80x38 mm, 14.9K RPM, Non-hot-swappable Middle Cooling Fan (Optimal for computational performance); 3.5" to 2.5" Converter Tray; MCP-220-00140-0B; Black gen 8 hot-swap 3.5-to-2.5 Tool-less HDD tray, orange tab; TPM security module; AOM-TPM-9670H-S; SPI Capable TPM 2.0 Provisioned for Server, Horizontal Form Factor; TPM security module; AOM-TPM-9671H-S; SPI Capable TPM 1.2 Provisioned for Server, Horizontal Form Factor; Intel VROC RAID Key; AOC-VROCINTMOD AOC-VROCSTNMOD AOC-VROCPREMOD; Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only) Intel VROC Standard, RAID 0, 1, 10 Intel VROC Premium, RAID 0, 1, 5, 10; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); SuperDOM; Supermicro SATA DOM Solutions [ Details ]; Network Card(s); AOC-S40G-i2Q AOC-SGP-i2 AOC-SGP-i4 AOC-STG-b4S AOC-STGN-i2S AOC-STGN-i1S AOC-STG-i2T AOC-STG-i2; - - - - - - - -; Standard LP 2-port 40GbE controller, based on Intel Fortville XL710 Standard LP, 2x GbE RJ45, PCI-E x4, Intel i350AM2 Standard LP, 4x GbE RJ45, PCI-E x4, Intel i350 Standard LP, 4x 10GbE SFP+, PCI-E x8, Broadcom BCM57840S Standard LP, 2x 10GbE SFP+, PCI-E x8, Intel 82599ES Standard LP, 1x 10GbE SFP+, PCI-E x8, Intel 82599EN Standard LP, 2x 10GbE RJ45, PCI-E x8, Intel X540 Standard LP, 2x 10GbE CX4, PCI-E x8, Intel 82598EB; Part Number; Description; FAN-0191L4; 80x80x38 mm, 14.9K RPM, Non-hot-swappable Middle Cooling Fan (Optimal for computational performance); 3.5" to 2.5" Converter Tray; MCP-220-00140-0B; Black gen 8 hot-swap 3.5-to-2.5 Tool-less HDD tray, orange tab; TPM security module; AOM-TPM-9670H-S; SPI Capable TPM 2.0 Provisioned for Server, Horizontal Form Factor; TPM security module; AOM-TPM-9671H-S; SPI Capable TPM 1.2 Provisioned for Server, Horizontal Form Factor; Intel VROC RAID Key; AOC-VROCINTMOD AOC-VROCSTNMOD AOC-VROCPREMOD; Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only) Intel VROC Standard, RAID 0, 1, 10 Intel VROC Premium, RAID 0, 1, 5, 10; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); SuperDOM; Supermicro SATA DOM Solutions [ Details ]; Network Card(s); AOC-S40G-i2Q AOC-SGP-i2 AOC-SGP-i4 AOC-STG-b4S AOC-STGN-i2S AOC-STGN-i1S AOC-STG-i2T AOC-STG-i2; - - - - - - - -; Standard LP 2-port 40GbE controller, based on Intel Fortville XL710 Standard LP, 2x GbE RJ45, PCI-E x4, Intel i350AM2 Standard LP, 4x GbE RJ45, PCI-E x4, Intel i350 Standard LP, 4x 10GbE SFP+, PCI-E x8, Broadcom BCM57840S Standard LP, 2x 10GbE SFP+, PCI-E x8, Intel 82599ES Standard LP, 1x 10GbE SFP+, PCI-E x8, Intel 82599EN Standard LP, 2x 10GbE RJ45, PCI-E x8, Intel X540 Standard LP, 2x 10GbE CX4, PCI-E x8, Intel 82598EB; Part Number; Description; FAN-0191L4; 80x80x38 mm, 14.9K RPM, Non-hot-swappable Middle Cooling Fan (Optimal for computational performance); 3.5" to 2.5" Converter Tray; MCP-220-00140-0B; Black gen 8 hot-swap 3.5-to-2.5 Tool-less HDD tray, orange tab; TPM security module; AOM-TPM-9670H-S; SPI Capable TPM 2.0 Provisioned for Server, Horizontal Form Factor; TPM security module; AOM-TPM-9671H-S; SPI Capable TPM 1.2 Provisioned for Server, Horizontal Form Factor; Intel VROC RAID Key; AOC-VROCINTMOD AOC-VROCSTNMOD AOC-VROCPREMOD; Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only) Intel VROC Standard, RAID 0, 1, 10 Intel VROC Premium, RAID 0, 1, 5, 10; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); SuperDOM; Supermicro SATA DOM Solutions [ Details ]; Network Card(s); AOC-S40G-i2Q AOC-SGP-i2 AOC-SGP-i4 AOC-STG-b4S AOC-STGN-i2S AOC-STGN-i1S AOC-STG-i2T AOC-STG-i2; - - - - - - - -; Standard LP 2-port 40GbE controller, based on Intel Fortville XL710 Standard LP, 2x GbE RJ45, PCI-E x4, Intel i350AM2 Standard LP, 4x GbE RJ45, PCI-E x4, Intel i350 Standard LP, 4x 10GbE SFP+, PCI-E x8, Broadcom BCM57840S Standard LP, 2x 10GbE SFP+, PCI-E x8, Intel 82599ES Standard LP, 1x 10GbE SFP+, PCI-E x8, Intel 82599EN Standard LP, 2x 10GbE RJ45, PCI-E x8, Intel X540 Standard LP, 2x 10GbE CX4, PCI-E x8, Intel 82598EB; Part Number; Description; FAN-0191L4; 80x80x38 mm, 14.9K RPM, Non-hot-swappable Middle Cooling Fan (Optimal for computational performance); 3.5" to 2.5" Converter Tray; MCP-220-00140-0B; Black gen 8 hot-swap 3.5-to-2.5 Tool-less HDD tray, orange tab; TPM security module; AOM-TPM-9670H-S; SPI Capable TPM 2.0 Provisioned for Server, Horizontal Form Factor; TPM security module; AOM-TPM-9671H-S; SPI Capable TPM 1.2 Provisioned for Server, Horizontal Form Factor; Intel VROC RAID Key; AOC-VROCINTMOD AOC-VROCSTNMOD AOC-VROCPREMOD; Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only) Intel VROC Standard, RAID 0, 1, 10 Intel VROC Premium, RAID 0, 1, 5, 10; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); SuperDOM; Supermicro SATA DOM Solutions [ Details ]; Network Card(s); AOC-S40G-i2Q AOC-SGP-i2 AOC-SGP-i4 AOC-STG-b4S AOC-STGN-i2S AOC-STGN-i1S AOC-STG-i2T AOC-STG-i2; - - - - - - - -; Standard LP 2-port 40GbE controller, based on Intel Fortville XL710 Standard LP, 2x GbE RJ45, PCI-E x4, Intel i350AM2 Standard LP, 4x GbE RJ45, PCI-E x4, Intel i350 Standard LP, 4x 10GbE SFP+, PCI-E x8, Broadcom BCM57840S Standard LP, 2x 10GbE SFP+, PCI-E x8, Intel 82599ES Standard LP, 1x 10GbE SFP+, PCI-E x8, Intel 82599EN Standard LP, 2x 10GbE RJ45, PCI-E x8, Intel X540 Standard LP, 2x 10GbE CX4, PCI-E x8, Intel 82598EB |
| On-Board Devices - SAS | SAS3 (12Gbps) via Broadcom 3008; IT mode |
| Management - Software | Intel® Node Manager IPMI 2.0 KVM with dedicated LAN SSM , SPM , SUM SuperDoctor® 5 Watch Dog |
| Management - Power Configurations | ACPI / APM Power Management |
| PC Health Monitoring - CPU | Monitors for CPU Cores, Chipset Voltages, Memory. 4+1 Phase-switching voltage regulator |
| Processor - Cores | Up to 28 Cores |
| System Memory - Note | † 2933MHz in two DIMMs per channel can be achieved by using memory purchased from Supermicro †† Cascade Lake only. Contact your Supermicro sales rep for more info. |
| Operating Environment - RoHS | RoHS Compliant |
| Operating Environment - Environmental Spec | Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F) Non-operating Temperature: -40°C to 60°C (-40°F to 140°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) |
| Power Supply - Total Output Power | 1200W/1800W/1980W/2090/2200W |
| Power Supply - DimensionW x H x L | 45 x 40 x 480 mm |
| Power Supply - Input | 1200W: 100-127Vac / 50-60Hz 1800W: 200-220Vac / 50-60Hz 1980W: 220-230Vac / 50-60Hz 2090W: 230-240Vac / 50-60Hz 2090W: 180-220Vac (for UL/cUL only) 2200W: 220-240Vac (for UL/cUL only) 2090W: 230-240Vdc (for CCC only) |
| Power Supply - 12Vsb | Max: 2.1A / Min: 0A |
| Power Supply - Output Type | Gold Finger |
| On-Board Devices - Network | Must bundle with at least one SIOM network card |
| Input Output per Node - LAN | 1 RJ45 Dedicated IPMI LAN port |
| Input Output per Node - USB | 2 USB 3.0 ports (rear) |
| Input Output per Node - Video | 1 VGA port |
| Input Output per Node - DOM | 1 Super DOM (Disk on Module) port |
| Input Output per Node - Others | M.2 and SATA DOM for boot drive only |
| Expansion Slots per Node - PCI-Express | 2 PCI-E 3.0 x8 slots 1 PCI-E 3.0 x16 slot 1 SIOM card support (must bundle with network card) |
| Drive Bays Storage per Node - Hot-swap | 6 SAS3 or 3 NVMe + 3 SAS3 Hot-swap 3.5" drive bays Please contact Supermicro Technical Support for additional information about HDD and SSD if mixed. Some restrictions and configuration rules that apply to SSD are different from HDD. |
| Drive Bays Storage per Node - M2 | 2 Internal M.2 NVMe/SATA slots |
| Product SKUs - SYS-6029BT-DNC0R | SuperServer 6029BT-DNC0R ( Black ) |
Отзывы
Загрузка отзывов...
Добавить отзыв
Оплачивайте покупки удобным способом. В интернет-магазине доступно 3 варианта оплаты:
- Наличные при самовывозе или доставке курьером. Специалист свяжется с вами в день доставки, чтобы уточнить время и заранее подготовить сдачу с любой купюры. Вы подписываете товаросопроводительные документы, вносите денежные средства, получаете товар и чек.
- Безналичный расчет при самовывозе или оформлении в интернет-магазине: карты МИР, Visa и MasterCard. Чтобы оплатить покупку, система перенаправит вас на сервер системы ASSIST. Здесь нужно ввести номер карты, срок действия и имя держателя.
- ЮMoney при онлайн-заказе. Для совершения покупки система перенаправит вас на страницу платежного сервиса. Здесь необходимо заполнить форму по инструкции.
Экономьте время на получении заказа. В интернет-магазине доступно 4 варианта доставки:
- Курьерская доставка работает с 9.00 до 19.00. Когда товар поступит на склад, курьерская служба свяжется для уточнения деталей. Специалист предложит выбрать удобное время доставки и уточнит адрес. Осмотрите упаковку на целостность и соответствие указанной комплектации.
- Самовывоз из магазина. Список торговых точек для выбора появится в корзине. Когда заказ поступит на склад, вам придет уведомление. Для получения заказа обратитесь к сотруднику в кассовой зоне и назовите номер.
- Постамат. Когда заказ поступит на точку, на ваш телефон или e-mail придет уникальный код. Заказ нужно оплатить в терминале постамата. Срок хранения — 3 дня.
- Почтовая доставка через почту России. Когда заказ придет в отделение, на ваш адрес придет извещение о посылке. Перед оплатой вы можете оценить состояние коробки: вес, целостность. Вскрывать коробку самостоятельно вы можете только после оплаты заказа. Один заказ может содержать не больше 10 позиций и его стоимость не должна превышать 100 000 р.