SuperServer 6029U-E1CR
Арт. SYS-6029TR-HTR
Нашли дешевле?
| PC Health Monitoring - FAN | Fans with tachometer monitoring Status monitor for speed control Pulse Width Modulated (PWM) fan connectors |
| PC Health Monitoring - Temperature | Monitoring for CPU and chassis environment Thermal Control for fan connectors |
| Chassis - Form Factor | 2U Rackmount |
| Chassis - Model | CSE-827HQ-R1K68BP3 |
| Dimensions and Weight - Height | 3.47" (88mm) |
| Dimensions and Weight - Width | 17.25" (438mm) |
| Dimensions and Weight - Depth | 28.5" (724mm) |
| Dimensions and Weight - Weight | Gross Weight: 73.5 lbs (33.34kg) Net Weight: 52.1 lbs (23.63kg) |
| Dimensions and Weight - Available Colors | Black |
| Front Panel - Buttons | Power On/Off button UID button |
| Front Panel - LEDs | Power status LED HDD activity LED Network activity LEDs Universal Information (UID) LED |
| System Cooling - Fans | 4x 8cm heavy duty PWM fans with optimal fan speed controlled |
| System BIOS - BIOS Type | AMI 32Mb SPI Flash ROM with UEFI |
| Parts List - Items Included | Part Number; Description; Motherboard / Chassis; MBD-X11DPT-L CSE-827HQ-R1K68BP3; Super X11DPT-L Motherboard 2U Chassis; Backplane; BPN-ADP-6SATA3M2-1UL; 6 x SATA3 with 6Gb/s,onboard 1 x M.2 . 22x80 mm and 22x110 mm,HF,RoHS; Backplane; BPN-SAS2-827HQ2; 2U 12-Port 4-Node 6Gbps Backplane Supports 3x3.5; Cable 1; CBL-PWCD-0900; PWCD,US/EU/Canada/China/Australia,IEC60320 C14 TO C13,4FT,17AWG; Air Shroud; MCP-310-82722-0B; SC827HQ mylar air shroud for on MBD-X11DPT-L-P; Manual; MNL-2163-QRG; 6029TR-HTR Quick Reference Guide; Riser Card; RSC-R1UTP-E16R; 1U RHS TwinPro Riser card with one PCI-E x16 slot; Heatsink / Retention; SNK-P0067PS; 1U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Heatsink / Retention; SNK-P0067PSM; 1U Passive CPU Heat Sink with a 26-mm Wide Middle Air Channel for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Power Supply; PWS-1K68A-1R; 1U 1600W Redundant Titanium Power Supply 76mm width 27Pair,PBF; FAN-0162L4; 80x80x38 mm, 13.5K RPM, HCP, LMV, and LPC Cooling Fan,RoHS/REACH; Part Number; Description; Motherboard / Chassis; MBD-X11DPT-L CSE-827HQ-R1K68BP3; Super X11DPT-L Motherboard 2U Chassis; Backplane; BPN-ADP-6SATA3M2-1UL; 6 x SATA3 with 6Gb/s,onboard 1 x M.2 . 22x80 mm and 22x110 mm,HF,RoHS; Backplane; BPN-SAS2-827HQ2; 2U 12-Port 4-Node 6Gbps Backplane Supports 3x3.5; Cable 1; CBL-PWCD-0900; PWCD,US/EU/Canada/China/Australia,IEC60320 C14 TO C13,4FT,17AWG; Air Shroud; MCP-310-82722-0B; SC827HQ mylar air shroud for on MBD-X11DPT-L-P; Manual; MNL-2163-QRG; 6029TR-HTR Quick Reference Guide; Riser Card; RSC-R1UTP-E16R; 1U RHS TwinPro Riser card with one PCI-E x16 slot; Heatsink / Retention; SNK-P0067PS; 1U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Heatsink / Retention; SNK-P0067PSM; 1U Passive CPU Heat Sink with a 26-mm Wide Middle Air Channel for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Power Supply; PWS-1K68A-1R; 1U 1600W Redundant Titanium Power Supply 76mm width 27Pair,PBF; FAN-0162L4; 80x80x38 mm, 13.5K RPM, HCP, LMV, and LPC Cooling Fan,RoHS/REACH; Part Number; Description; Motherboard / Chassis; MBD-X11DPT-L CSE-827HQ-R1K68BP3; Super X11DPT-L Motherboard 2U Chassis; Backplane; BPN-ADP-6SATA3M2-1UL; 6 x SATA3 with 6Gb/s,onboard 1 x M.2 . 22x80 mm and 22x110 mm,HF,RoHS; Backplane; BPN-SAS2-827HQ2; 2U 12-Port 4-Node 6Gbps Backplane Supports 3x3.5; Cable 1; CBL-PWCD-0900; PWCD,US/EU/Canada/China/Australia,IEC60320 C14 TO C13,4FT,17AWG; Air Shroud; MCP-310-82722-0B; SC827HQ mylar air shroud for on MBD-X11DPT-L-P; Manual; MNL-2163-QRG; 6029TR-HTR Quick Reference Guide; Riser Card; RSC-R1UTP-E16R; 1U RHS TwinPro Riser card with one PCI-E x16 slot; Heatsink / Retention; SNK-P0067PS; 1U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Heatsink / Retention; SNK-P0067PSM; 1U Passive CPU Heat Sink with a 26-mm Wide Middle Air Channel for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Power Supply; PWS-1K68A-1R; 1U 1600W Redundant Titanium Power Supply 76mm width 27Pair,PBF; FAN-0162L4; 80x80x38 mm, 13.5K RPM, HCP, LMV, and LPC Cooling Fan,RoHS/REACH; Part Number; Description; Motherboard / Chassis; MBD-X11DPT-L CSE-827HQ-R1K68BP3; Super X11DPT-L Motherboard 2U Chassis; Backplane; BPN-ADP-6SATA3M2-1UL; 6 x SATA3 with 6Gb/s,onboard 1 x M.2 . 22x80 mm and 22x110 mm,HF,RoHS; Backplane; BPN-SAS2-827HQ2; 2U 12-Port 4-Node 6Gbps Backplane Supports 3x3.5; Cable 1; CBL-PWCD-0900; PWCD,US/EU/Canada/China/Australia,IEC60320 C14 TO C13,4FT,17AWG; Air Shroud; MCP-310-82722-0B; SC827HQ mylar air shroud for on MBD-X11DPT-L-P; Manual; MNL-2163-QRG; 6029TR-HTR Quick Reference Guide; Riser Card; RSC-R1UTP-E16R; 1U RHS TwinPro Riser card with one PCI-E x16 slot; Heatsink / Retention; SNK-P0067PS; 1U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Heatsink / Retention; SNK-P0067PSM; 1U Passive CPU Heat Sink with a 26-mm Wide Middle Air Channel for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Power Supply; PWS-1K68A-1R; 1U 1600W Redundant Titanium Power Supply 76mm width 27Pair,PBF; FAN-0162L4; 80x80x38 mm, 13.5K RPM, HCP, LMV, and LPC Cooling Fan,RoHS/REACH |
| Optional Parts List | Part Number; Description; TPM security module (optional, not included); AOM-TPM-9670V; SPI capable TPM 2.0 with Infineon 9670 controller with vertical form factor; TPM security module (optional, not included); AOM-TPM-9671V; SPI capable TPM 1.2 with Infineon 9670 controller with vertical form factor; Hot-swap 3.5" to 2.5" Hard Disk Drive Tray; MCP-220-00043-0N; Black Hot-swap gen 4 3.5" to 2.5" HDD tray; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; TPM security module (optional, not included); AOM-TPM-9670V; SPI capable TPM 2.0 with Infineon 9670 controller with vertical form factor; TPM security module (optional, not included); AOM-TPM-9671V; SPI capable TPM 1.2 with Infineon 9670 controller with vertical form factor; Hot-swap 3.5" to 2.5" Hard Disk Drive Tray; MCP-220-00043-0N; Black Hot-swap gen 4 3.5" to 2.5" HDD tray; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; TPM security module (optional, not included); AOM-TPM-9670V; SPI capable TPM 2.0 with Infineon 9670 controller with vertical form factor; TPM security module (optional, not included); AOM-TPM-9671V; SPI capable TPM 1.2 with Infineon 9670 controller with vertical form factor; Hot-swap 3.5" to 2.5" Hard Disk Drive Tray; MCP-220-00043-0N; Black Hot-swap gen 4 3.5" to 2.5" HDD tray; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; TPM security module (optional, not included); AOM-TPM-9670V; SPI capable TPM 2.0 with Infineon 9670 controller with vertical form factor; TPM security module (optional, not included); AOM-TPM-9671V; SPI capable TPM 1.2 with Infineon 9670 controller with vertical form factor; Hot-swap 3.5" to 2.5" Hard Disk Drive Tray; MCP-220-00043-0N; Black Hot-swap gen 4 3.5" to 2.5" HDD tray; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license) |
| Management - Software | Intel® Node Manager IPMI 2.0 KVM with dedicated LAN NMI SSM , SPM , SUM SuperDoctor® 5 Watchdog |
| Power Supply 76mm Width | 1600W 1U Redundant Power Supplies with PMBus; 1600W 1U Redundant Power Supplies with PMBus; 1600W 1U Redundant Power Supplies with PMBus; 1600W 1U Redundant Power Supplies with PMBus |
| Power Supply 76mm Width - Total Output Power | 800W: 100 – 140Vac 1600W: 180 – 240Vac |
| Power Supply 76mm Width - DimensionW x H x L | 76 x 40.4 x 336 mm |
| Power Supply 76mm Width - Input | 100-140Vac / 10-7A / 50-60Hz 180-240Vac / 11-8A / 50-60Hz |
| Power Supply 76mm Width - 12V | Max: 67A / Min: 0A (100-140Vac) Max: 133A / Min: 0A (180-240Vac) |
| Power Supply 76mm Width - 5Vsb | Max: 1A / Min: 0A |
| Power Supply 76mm Width - Output Type | 27 Pairs Gold Finger Connector |
| Power Supply 76mm Width - Certification | Titanium Level [ Test Report ] |
| PC Health Monitoring - CPU | Monitors for CPU Cores, Chipset Voltages, Memory. 4+1 Phase-switching voltage regulator |
| Operating Environment - RoHS | RoHS Compliant |
| Operating Environment - Environmental Spec | Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F) Non-operating Temperature: -40°C to 60°C (-40°F to 140°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) |
| Processor per Node - CPU | Dual Socket P (LGA 3647) 2nd Gen Intel® Xeon® Scalable Processors and Intel® Xeon® Scalable Processors ‡ , Dual UPI up to 10.4GT/s Support CPU TDP 70-140W |
| Processor per Node - Cores | Up to 22 Cores |
| Processor per Node - Note | ‡ BIOS version 3.2 or above is required to support 2nd Gen Intel® Xeon® Scalable processors (codenamed Cascade Lake-R) |
| System Memory per Node - Memory Capacity | 8 DIMM slots Up to 2TB 3DS ECC DDR4-2933MHz † RDIMM/LRDIMM |
| System Memory per Node - Memory Type | 2933 † /2666/2400/2133MHz ECC DDR4 RDIMM/LRDIMM |
| System Memory per Node - Note | † 2933MHz in two DIMMs per channel can be achieved by using memory purchased from Supermicro |
| Input Output per Node - LAN | 2 RJ45 Gigabit Ethernet LAN ports 1 RJ45 Dedicated IPMI LAN port |
| Input Output per Node - USB | 2 USB 3.0 ports total (rear) |
| Input Output per Node - Others | TPM 2.0 Header |
| Expansion Slots per Node - PCI-Express | 1 PCI-E 3.0 x16 Low-profile slot |
| Drive Bays Storage per Node - Hot-swap | 3 Hot-swap 3.5" SATA3 HDD trays |
| Motherboard Four per System | Super X11DPT-L; Super X11DPT-L; Super X11DPT-L; Super X11DPT-L |
| On-Board Devices per Node - Chipset | Intel® C621 chipset |
| On-Board Devices per Node - SATA | SATA3 (6Gbps); RAID 0, 1, 5 support |
| On-Board Devices per Node - Network Controllers | Intel® C621 chipset |
| On-Board Devices per Node - IPMI | Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support |
| On-Board Devices per Node - Graphics | ASPEED AST2500 BMC |
| Input Output per Node - SATA | 3 SATA3 (6Gbps) ports |
| Input Output per Node - VGA | 1 VGA port |
| Input Output per Node - Serial Port Header | 1 COM Port (1 rear) |
| Product SKUs - SYS-6029TR-HTR | SuperServer 6029TR-HTR ( Black ) |
| Drive Bays Storage per Node - Others | 2 SATA DOM 1 PCI-E 3.0 x4 NVMe or 1 SATA M.2 (22110/2280) support via BPN-ADP-6SATA3M2-1UL * M.2 and SuperDOM are for OS boot |
Отзывы
Загрузка отзывов...
Добавить отзыв
Оплачивайте покупки удобным способом. В интернет-магазине доступно 3 варианта оплаты:
- Наличные при самовывозе или доставке курьером. Специалист свяжется с вами в день доставки, чтобы уточнить время и заранее подготовить сдачу с любой купюры. Вы подписываете товаросопроводительные документы, вносите денежные средства, получаете товар и чек.
- Безналичный расчет при самовывозе или оформлении в интернет-магазине: карты МИР, Visa и MasterCard. Чтобы оплатить покупку, система перенаправит вас на сервер системы ASSIST. Здесь нужно ввести номер карты, срок действия и имя держателя.
- ЮMoney при онлайн-заказе. Для совершения покупки система перенаправит вас на страницу платежного сервиса. Здесь необходимо заполнить форму по инструкции.
Экономьте время на получении заказа. В интернет-магазине доступно 4 варианта доставки:
- Курьерская доставка работает с 9.00 до 19.00. Когда товар поступит на склад, курьерская служба свяжется для уточнения деталей. Специалист предложит выбрать удобное время доставки и уточнит адрес. Осмотрите упаковку на целостность и соответствие указанной комплектации.
- Самовывоз из магазина. Список торговых точек для выбора появится в корзине. Когда заказ поступит на склад, вам придет уведомление. Для получения заказа обратитесь к сотруднику в кассовой зоне и назовите номер.
- Постамат. Когда заказ поступит на точку, на ваш телефон или e-mail придет уникальный код. Заказ нужно оплатить в терминале постамата. Срок хранения — 3 дня.
- Почтовая доставка через почту России. Когда заказ придет в отделение, на ваш адрес придет извещение о посылке. Перед оплатой вы можете оценить состояние коробки: вес, целостность. Вскрывать коробку самостоятельно вы можете только после оплаты заказа. Один заказ может содержать не больше 10 позиций и его стоимость не должна превышать 100 000 р.