| Motherboard | Super X11DPi-N; Super X11DPi-N; Super X11DPi-N; Super X11DPi-N |
| Processor - CPU | Dual Socket P (LGA 3647) 2nd Gen Intel® Xeon® Scalable Processors and Intel® Xeon® Scalable Processors ‡ , Dual UPI up to 10.4GT/s Support CPU TDP 70-205W |
| Processor - Note | ‡ BIOS version 3.2 or above is required to support 2nd Gen Intel® Xeon® Scalable processors (codenamed Cascade Lake-R) * CPU SKUs not supported: Gold 6256 and Gold 6250(L) (L = increased memory capacity per socket), Gold 6233W and Gold 5216W |
| System Memory - Memory Capacity | 16 DIMM slots Up to 4TB 3DS ECC DDR4-2933MHz † RDIMM/LRDIMM Supports Intel® Optane™ DCPMM †† |
| System Memory - Memory Type | 2933 † /2666/2400/2133MHz ECC DDR4 RDIMM/LRDIMM |
| On-Board Devices - Chipset | Intel® C621 chipset |
| On-Board Devices - SATA | SATA3 (6Gbps); RAID 0, 1, 5, 10 |
| On-Board Devices - IPMI | Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support |
| On-Board Devices - Network Controllers | Dual 1GbE LAN with Intel® X722 |
| On-Board Devices - Video | ASPEED AST2500 BMC |
| Input Output - SATA | 8 SATA3 (6Gbps) ports |
| Input Output - LAN | 2 RJ45 Gigabit Ethernet LAN ports 1 RJ45 Dedicated IPMI LAN port |
| Input Output - USB | Rear USB: 2 USB 3.0 + 2 USB 2.0 Front USB: 2 USB 3.0 USB Header: 1 Type A |
| Input Output - Video | 1 VGA port |
| Input Output - Serial Port Header | 2 Fast UART 16550 serial 2 COM Ports (1 rear, 1 header) |
| PC Health Monitoring - FAN | Fans with tachometer monitoring Status monitor for speed control Pulse Width Modulated (PWM) fan connectors |
| PC Health Monitoring - Temperature | Monitoring for CPU and chassis environment Thermal Control for fan connectors |
| Chassis - Form Factor | 4U Rackmountable / Tower Optional Rackmount Kit |
| Chassis - Model | CSE-745BTS-R1K23B |
| Dimensions and Weight - Height | 17.8" (452mm) |
| Dimensions and Weight - Width | 7.0" (178mm) |
| Dimensions and Weight - Depth | 25.5" (648mm) |
| Dimensions and Weight - Package | 24" (H) x 14" (W) x 26.5" (D) |
| Dimensions and Weight - Weight | Net Weight: 56 lbs (25.6 kg) Gross Weight: 73.5 lbs (33.6 kg) |
| Dimensions and Weight - Available Colors | Black |
| Front Panel - Buttons | Power On/Off button System Reset button |
| Front Panel - LEDs | Power LED Hard drive activity LED Network activity LEDs System Information LED Power Fail LED |
| Expansion Slots - PCI-Express | 4 PCI-E 3.0 x16 slots 2 PCI-E 3.0 x8 slots Support total of 6 Full-height AOC |
| Drive Bays - Hot-swap | 8 Hot-swap 2.5"/3.5" SATA3 (6Gbps) drive bays |
| System Cooling - Fans | 3x 80mm high-performance fans 2x 80mm PWM Rear Chassis fans |
| Power Supply | 1200W Redundant High-efficiency Power Supplies; 1200W Redundant High-efficiency Power Supplies; 1200W Redundant High-efficiency Power Supplies; 1200W Redundant High-efficiency Power Supplies |
| Power Supply - 12V | Max: 83A & Min: 0A (100Vac-127Vac) Max: 100A & Min: 0A (200Vac-240Vac) |
| Power Supply - Certification | Titanium Level |
| System BIOS - BIOS Type | AMI UEFI |
| Parts List - Items Included | Part Number; Description; Motherboard / Chassis; MBD-X11DPi-N CSE-745BTS-R1K23B; Super X11DPi-N Motherboard 4U Chassis; Backplane; BPN-SAS3-743A; 8-port 4U/Tower 3.5-inch SAS3/SAS2/SATA3 12Gbps backplane for SC743/SC745 chassis; Cable 1; CBL-SAST-0508-01; MINI SAS HD-MINI SAS,6G,INT,50CM,SB,30AWG; Cable 2; CBL-SAST-0508-02; MINI SAS HD-MINI SAS,6G,INT,50CM,SB,30AWG; MCP-260-00042-0N; STD I/O shield for X9 socket R server MB with Gasket.; Manual; MNL-1940-QRG; SYS-7049P-TR/SYS-7049P-TRT, QRG; Heatsink / Retention; SNK-P0068PS; 2U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; * Power Supply; PWS-1K23A-SQ; 1U, Redundancy, Titanium, Input: 100-127Vac, 200-240Vac; * Power Distributor; PDB-PT747-4648; POWER DISTRIBUTOR FOR SC747 W/ GRAPHIC OUTPUT FEATURE; * Cable 3; CBL-0087; CBL,FRONT CNTL,16 TO 16 PIN,Ribbon,50CM; * Cable 4; CBL-0160L; NEMA5-15P to C13 US power cord 16AWG 6ft, PBF (default for high watt); * Cable 5; CBL-0216L; 4 PIN TO 4 PIN MIDDLE FAN POWER EXTENSION, 20cm. 24AWG(PWM); * Cable 6; CBL-0471L; USB 3.0,INT,19 PIN/F TO 19PIN/F,2 CH,80CM,30/28/26AWG; * FAN 1; FAN-0180L4; 80x80x38 mm, 9.4K RPM, Hot-swappable Rear Exhaust Fan for X11 Purley Platform Newly Enabled 4U Chassis; * FAN 2; FAN-0182L4; 80x80x38 mm, 9.4K RPM, Hot-swappable Middle Cooling Fan for X11 Purley Platform Newly Enabled 4U Chassis; * Drive Tray(s); MCP-220-00092-0B; Black Hot-swap 3.5inch HDD Tray (w/o logo); * Parts; MCP-290-74502-0B; Plastic feet (4 pcs set) for 4U tower chassis, black color; * Air Shroud; MCP-310-49001-0N; SC745 Intel DP X9, X8 PC air shroud 1368x13/12x13MB; Part Number; Description; Motherboard / Chassis; MBD-X11DPi-N CSE-745BTS-R1K23B; Super X11DPi-N Motherboard 4U Chassis; Backplane; BPN-SAS3-743A; 8-port 4U/Tower 3.5-inch SAS3/SAS2/SATA3 12Gbps backplane for SC743/SC745 chassis; Cable 1; CBL-SAST-0508-01; MINI SAS HD-MINI SAS,6G,INT,50CM,SB,30AWG; Cable 2; CBL-SAST-0508-02; MINI SAS HD-MINI SAS,6G,INT,50CM,SB,30AWG; MCP-260-00042-0N; STD I/O shield for X9 socket R server MB with Gasket.; Manual; MNL-1940-QRG; SYS-7049P-TR/SYS-7049P-TRT, QRG; Heatsink / Retention; SNK-P0068PS; 2U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; * Power Supply; PWS-1K23A-SQ; 1U, Redundancy, Titanium, Input: 100-127Vac, 200-240Vac; * Power Distributor; PDB-PT747-4648; POWER DISTRIBUTOR FOR SC747 W/ GRAPHIC OUTPUT FEATURE; * Cable 3; CBL-0087; CBL,FRONT CNTL,16 TO 16 PIN,Ribbon,50CM; * Cable 4; CBL-0160L; NEMA5-15P to C13 US power cord 16AWG 6ft, PBF (default for high watt); * Cable 5; CBL-0216L; 4 PIN TO 4 PIN MIDDLE FAN POWER EXTENSION, 20cm. 24AWG(PWM); * Cable 6; CBL-0471L; USB 3.0,INT,19 PIN/F TO 19PIN/F,2 CH,80CM,30/28/26AWG; * FAN 1; FAN-0180L4; 80x80x38 mm, 9.4K RPM, Hot-swappable Rear Exhaust Fan for X11 Purley Platform Newly Enabled 4U Chassis; * FAN 2; FAN-0182L4; 80x80x38 mm, 9.4K RPM, Hot-swappable Middle Cooling Fan for X11 Purley Platform Newly Enabled 4U Chassis; * Drive Tray(s); MCP-220-00092-0B; Black Hot-swap 3.5inch HDD Tray (w/o logo); * Parts; MCP-290-74502-0B; Plastic feet (4 pcs set) for 4U tower chassis, black color; * Air Shroud; MCP-310-49001-0N; SC745 Intel DP X9, X8 PC air shroud 1368x13/12x13MB; Part Number; Description; Motherboard / Chassis; MBD-X11DPi-N CSE-745BTS-R1K23B; Super X11DPi-N Motherboard 4U Chassis; Backplane; BPN-SAS3-743A; 8-port 4U/Tower 3.5-inch SAS3/SAS2/SATA3 12Gbps backplane for SC743/SC745 chassis; Cable 1; CBL-SAST-0508-01; MINI SAS HD-MINI SAS,6G,INT,50CM,SB,30AWG; Cable 2; CBL-SAST-0508-02; MINI SAS HD-MINI SAS,6G,INT,50CM,SB,30AWG; MCP-260-00042-0N; STD I/O shield for X9 socket R server MB with Gasket.; Manual; MNL-1940-QRG; SYS-7049P-TR/SYS-7049P-TRT, QRG; Heatsink / Retention; SNK-P0068PS; 2U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; * Power Supply; PWS-1K23A-SQ; 1U, Redundancy, Titanium, Input: 100-127Vac, 200-240Vac; * Power Distributor; PDB-PT747-4648; POWER DISTRIBUTOR FOR SC747 W/ GRAPHIC OUTPUT FEATURE; * Cable 3; CBL-0087; CBL,FRONT CNTL,16 TO 16 PIN,Ribbon,50CM; * Cable 4; CBL-0160L; NEMA5-15P to C13 US power cord 16AWG 6ft, PBF (default for high watt); * Cable 5; CBL-0216L; 4 PIN TO 4 PIN MIDDLE FAN POWER EXTENSION, 20cm. 24AWG(PWM); * Cable 6; CBL-0471L; USB 3.0,INT,19 PIN/F TO 19PIN/F,2 CH,80CM,30/28/26AWG; * FAN 1; FAN-0180L4; 80x80x38 mm, 9.4K RPM, Hot-swappable Rear Exhaust Fan for X11 Purley Platform Newly Enabled 4U Chassis; * FAN 2; FAN-0182L4; 80x80x38 mm, 9.4K RPM, Hot-swappable Middle Cooling Fan for X11 Purley Platform Newly Enabled 4U Chassis; * Drive Tray(s); MCP-220-00092-0B; Black Hot-swap 3.5inch HDD Tray (w/o logo); * Parts; MCP-290-74502-0B; Plastic feet (4 pcs set) for 4U tower chassis, black color; * Air Shroud; MCP-310-49001-0N; SC745 Intel DP X9, X8 PC air shroud 1368x13/12x13MB; Part Number; Description; Motherboard / Chassis; MBD-X11DPi-N CSE-745BTS-R1K23B; Super X11DPi-N Motherboard 4U Chassis; Backplane; BPN-SAS3-743A; 8-port 4U/Tower 3.5-inch SAS3/SAS2/SATA3 12Gbps backplane for SC743/SC745 chassis; Cable 1; CBL-SAST-0508-01; MINI SAS HD-MINI SAS,6G,INT,50CM,SB,30AWG; Cable 2; CBL-SAST-0508-02; MINI SAS HD-MINI SAS,6G,INT,50CM,SB,30AWG; MCP-260-00042-0N; STD I/O shield for X9 socket R server MB with Gasket.; Manual; MNL-1940-QRG; SYS-7049P-TR/SYS-7049P-TRT, QRG; Heatsink / Retention; SNK-P0068PS; 2U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; * Power Supply; PWS-1K23A-SQ; 1U, Redundancy, Titanium, Input: 100-127Vac, 200-240Vac; * Power Distributor; PDB-PT747-4648; POWER DISTRIBUTOR FOR SC747 W/ GRAPHIC OUTPUT FEATURE; * Cable 3; CBL-0087; CBL,FRONT CNTL,16 TO 16 PIN,Ribbon,50CM; * Cable 4; CBL-0160L; NEMA5-15P to C13 US power cord 16AWG 6ft, PBF (default for high watt); * Cable 5; CBL-0216L; 4 PIN TO 4 PIN MIDDLE FAN POWER EXTENSION, 20cm. 24AWG(PWM); * Cable 6; CBL-0471L; USB 3.0,INT,19 PIN/F TO 19PIN/F,2 CH,80CM,30/28/26AWG; * FAN 1; FAN-0180L4; 80x80x38 mm, 9.4K RPM, Hot-swappable Rear Exhaust Fan for X11 Purley Platform Newly Enabled 4U Chassis; * FAN 2; FAN-0182L4; 80x80x38 mm, 9.4K RPM, Hot-swappable Middle Cooling Fan for X11 Purley Platform Newly Enabled 4U Chassis; * Drive Tray(s); MCP-220-00092-0B; Black Hot-swap 3.5inch HDD Tray (w/o logo); * Parts; MCP-290-74502-0B; Plastic feet (4 pcs set) for 4U tower chassis, black color; * Air Shroud; MCP-310-49001-0N; SC745 Intel DP X9, X8 PC air shroud 1368x13/12x13MB |
| Optional Parts List | Part Number; Description; Storage Controller Card(s) & Cables(s); AOC-S3008L-L8i & 2x CBL-SAST-0531-01 AOC-S3008L-L8e & 2x CBL-SAST-0531-01 AOC-S3108L-H8IR & 2x CBL-SAST-0531-01 AOC-S3108L-H8IR-16DD & 2x CBL-SAST-0531-01; Standard LP, 8 internal ports (12Gb/s) Gen-3, 63HDD; RAID 0, 1, 10 Standard LP, 8 internal ports (12Gb/s) Gen-3, 122HDD; HBA Standard LP, 8 internal ports (12Gb/s) 8x Gen3; RAID 0, 1, 5, 6, 10, 50, 60 Standard LP, 8 internal ports (12Gb/s) Gen-3, 16HDD; RAID 0, 1, 5, 6, 10, 50, 60; Mounting Rails; CSE-PT26L-B; 4U Chassis Rail Kits SC743,745 (w/ 2pcs Black Chassis Ears); 5.25" SATA DVD drive; 5.25" DVD reader or writer; Any third party 5.25 inch SATA DVD reader or writer; SATA cable for DVD drive; CBL-0178L; SATA CABLE 48CM FLAT S-S PBF. 26AWG; SATA Power cable for DVD drive; CBL-0080L; Big 4 pin to SATA POWER ADAPTER CABLE 6", 18AWG; 2.5" NVMe fixed drive support; MCP-220-00160-0N; Dual 2.5" NVMe Drive BKT: 743, 745, 502, 503, 510, 512, 515; 2.5" NVMe fixed drive support; CBL-SAST-0956; Oculink to 1 NVMe drive w/ power, each NVMe drive needs 1 cable, system can support total 2 NVMe fixed drives; 3.5" to 2.5" HDD tray Converter; MCP-220-00080-0B; Black hot-swap gen2 3.5" to 2.5" HDD tray converter. Each 2.5" drive needs one converter, total 8x 2.5" Hot-swap drives can be supported; HDD Bracket; MCP-220-00044-0N; Dual 2.5" fixed HDD bracket for SC502, 503, 510, 512, 515U; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; Storage Controller Card(s) & Cables(s); AOC-S3008L-L8i & 2x CBL-SAST-0531-01 AOC-S3008L-L8e & 2x CBL-SAST-0531-01 AOC-S3108L-H8IR & 2x CBL-SAST-0531-01 AOC-S3108L-H8IR-16DD & 2x CBL-SAST-0531-01; Standard LP, 8 internal ports (12Gb/s) Gen-3, 63HDD; RAID 0, 1, 10 Standard LP, 8 internal ports (12Gb/s) Gen-3, 122HDD; HBA Standard LP, 8 internal ports (12Gb/s) 8x Gen3; RAID 0, 1, 5, 6, 10, 50, 60 Standard LP, 8 internal ports (12Gb/s) Gen-3, 16HDD; RAID 0, 1, 5, 6, 10, 50, 60; Mounting Rails; CSE-PT26L-B; 4U Chassis Rail Kits SC743,745 (w/ 2pcs Black Chassis Ears); 5.25" SATA DVD drive; 5.25" DVD reader or writer; Any third party 5.25 inch SATA DVD reader or writer; SATA cable for DVD drive; CBL-0178L; SATA CABLE 48CM FLAT S-S PBF. 26AWG; SATA Power cable for DVD drive; CBL-0080L; Big 4 pin to SATA POWER ADAPTER CABLE 6", 18AWG; 2.5" NVMe fixed drive support; MCP-220-00160-0N; Dual 2.5" NVMe Drive BKT: 743, 745, 502, 503, 510, 512, 515; 2.5" NVMe fixed drive support; CBL-SAST-0956; Oculink to 1 NVMe drive w/ power, each NVMe drive needs 1 cable, system can support total 2 NVMe fixed drives; 3.5" to 2.5" HDD tray Converter; MCP-220-00080-0B; Black hot-swap gen2 3.5" to 2.5" HDD tray converter. Each 2.5" drive needs one converter, total 8x 2.5" Hot-swap drives can be supported; HDD Bracket; MCP-220-00044-0N; Dual 2.5" fixed HDD bracket for SC502, 503, 510, 512, 515U; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; Storage Controller Card(s) & Cables(s); AOC-S3008L-L8i & 2x CBL-SAST-0531-01 AOC-S3008L-L8e & 2x CBL-SAST-0531-01 AOC-S3108L-H8IR & 2x CBL-SAST-0531-01 AOC-S3108L-H8IR-16DD & 2x CBL-SAST-0531-01; Standard LP, 8 internal ports (12Gb/s) Gen-3, 63HDD; RAID 0, 1, 10 Standard LP, 8 internal ports (12Gb/s) Gen-3, 122HDD; HBA Standard LP, 8 internal ports (12Gb/s) 8x Gen3; RAID 0, 1, 5, 6, 10, 50, 60 Standard LP, 8 internal ports (12Gb/s) Gen-3, 16HDD; RAID 0, 1, 5, 6, 10, 50, 60; Mounting Rails; CSE-PT26L-B; 4U Chassis Rail Kits SC743,745 (w/ 2pcs Black Chassis Ears); 5.25" SATA DVD drive; 5.25" DVD reader or writer; Any third party 5.25 inch SATA DVD reader or writer; SATA cable for DVD drive; CBL-0178L; SATA CABLE 48CM FLAT S-S PBF. 26AWG; SATA Power cable for DVD drive; CBL-0080L; Big 4 pin to SATA POWER ADAPTER CABLE 6", 18AWG; 2.5" NVMe fixed drive support; MCP-220-00160-0N; Dual 2.5" NVMe Drive BKT: 743, 745, 502, 503, 510, 512, 515; 2.5" NVMe fixed drive support; CBL-SAST-0956; Oculink to 1 NVMe drive w/ power, each NVMe drive needs 1 cable, system can support total 2 NVMe fixed drives; 3.5" to 2.5" HDD tray Converter; MCP-220-00080-0B; Black hot-swap gen2 3.5" to 2.5" HDD tray converter. Each 2.5" drive needs one converter, total 8x 2.5" Hot-swap drives can be supported; HDD Bracket; MCP-220-00044-0N; Dual 2.5" fixed HDD bracket for SC502, 503, 510, 512, 515U; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; Storage Controller Card(s) & Cables(s); AOC-S3008L-L8i & 2x CBL-SAST-0531-01 AOC-S3008L-L8e & 2x CBL-SAST-0531-01 AOC-S3108L-H8IR & 2x CBL-SAST-0531-01 AOC-S3108L-H8IR-16DD & 2x CBL-SAST-0531-01; Standard LP, 8 internal ports (12Gb/s) Gen-3, 63HDD; RAID 0, 1, 10 Standard LP, 8 internal ports (12Gb/s) Gen-3, 122HDD; HBA Standard LP, 8 internal ports (12Gb/s) 8x Gen3; RAID 0, 1, 5, 6, 10, 50, 60 Standard LP, 8 internal ports (12Gb/s) Gen-3, 16HDD; RAID 0, 1, 5, 6, 10, 50, 60; Mounting Rails; CSE-PT26L-B; 4U Chassis Rail Kits SC743,745 (w/ 2pcs Black Chassis Ears); 5.25" SATA DVD drive; 5.25" DVD reader or writer; Any third party 5.25 inch SATA DVD reader or writer; SATA cable for DVD drive; CBL-0178L; SATA CABLE 48CM FLAT S-S PBF. 26AWG; SATA Power cable for DVD drive; CBL-0080L; Big 4 pin to SATA POWER ADAPTER CABLE 6", 18AWG; 2.5" NVMe fixed drive support; MCP-220-00160-0N; Dual 2.5" NVMe Drive BKT: 743, 745, 502, 503, 510, 512, 515; 2.5" NVMe fixed drive support; CBL-SAST-0956; Oculink to 1 NVMe drive w/ power, each NVMe drive needs 1 cable, system can support total 2 NVMe fixed drives; 3.5" to 2.5" HDD tray Converter; MCP-220-00080-0B; Black hot-swap gen2 3.5" to 2.5" HDD tray converter. Each 2.5" drive needs one converter, total 8x 2.5" Hot-swap drives can be supported; HDD Bracket; MCP-220-00044-0N; Dual 2.5" fixed HDD bracket for SC502, 503, 510, 512, 515U; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license) |
| Management - Software | Intel® Node Manager IPMI 2.0 KVM with dedicated LAN NMI SSM , SPM , SUM SuperDoctor® 5 |
| Management - Power Configurations | ACPI Power Management |
| Input Output - DOM | 2 Super DOM (Disk on Module) ports |
| PC Health Monitoring - CPU | Monitors for CPU Cores, Chipset Voltages, Memory. 4+1 Phase-switching voltage regulator |
| Front Panel - Ports | 2 USB Ports |
| Processor - Cores | Up to 28 Cores |
| System Memory - Note | † 2933MHz in two DIMMs per channel can be achieved by using memory purchased from Supermicro †† Cascade Lake only. Contact your Supermicro sales rep for more info. |
| Operating Environment - RoHS | RoHS Compliant |
| Operating Environment - Environmental Spec | Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F) Non-operating Temperature: -40°C to 60°C (-40°F to 140°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) |
| Power Supply - Total Output Power | 1000W with Input 100 - 127Vac 1200W with Input 200 - 240Vac 1200W with Input 200 - 240Vdc (for CCC only) |
| Power Supply - DimensionW x H x L | 76 x 40 x 336 mm |
| Power Supply - Input | 50-60Hz |
| Product SKUs - SYS-7049P-TR | SuperServer 7049P-TR ( Black ) |
| Drive Bays - Peripheral Bays | 3 Peripheral 5.25" drive bays |
| SAS SATA Backplane | SAS / SATA Hard Drive Backplane w/AMI MG9072; SAS / SATA Hard Drive Backplane w/AMI MG9072; SAS / SATA Hard Drive Backplane w/AMI MG9072; SAS / SATA Hard Drive Backplane w/AMI MG9072 |
Отзывы
Загрузка отзывов...
Добавить отзыв
Оплачивайте покупки удобным способом. В интернет-магазине доступно 3 варианта оплаты:
- Наличные при самовывозе или доставке курьером. Специалист свяжется с вами в день доставки, чтобы уточнить время и заранее подготовить сдачу с любой купюры. Вы подписываете товаросопроводительные документы, вносите денежные средства, получаете товар и чек.
- Безналичный расчет при самовывозе или оформлении в интернет-магазине: карты МИР, Visa и MasterCard. Чтобы оплатить покупку, система перенаправит вас на сервер системы ASSIST. Здесь нужно ввести номер карты, срок действия и имя держателя.
- ЮMoney при онлайн-заказе. Для совершения покупки система перенаправит вас на страницу платежного сервиса. Здесь необходимо заполнить форму по инструкции.
Экономьте время на получении заказа. В интернет-магазине доступно 4 варианта доставки:
- Курьерская доставка работает с 9.00 до 19.00. Когда товар поступит на склад, курьерская служба свяжется для уточнения деталей. Специалист предложит выбрать удобное время доставки и уточнит адрес. Осмотрите упаковку на целостность и соответствие указанной комплектации.
- Самовывоз из магазина. Список торговых точек для выбора появится в корзине. Когда заказ поступит на склад, вам придет уведомление. Для получения заказа обратитесь к сотруднику в кассовой зоне и назовите номер.
- Постамат. Когда заказ поступит на точку, на ваш телефон или e-mail придет уникальный код. Заказ нужно оплатить в терминале постамата. Срок хранения — 3 дня.
- Почтовая доставка через почту России. Когда заказ придет в отделение, на ваш адрес придет извещение о посылке. Перед оплатой вы можете оценить состояние коробки: вес, целостность. Вскрывать коробку самостоятельно вы можете только после оплаты заказа. Один заказ может содержать не больше 10 позиций и его стоимость не должна превышать 100 000 р.