| Motherboard | Super X11DPG-HGX2; Super X11DPG-HGX2; Super X11DPG-HGX2; Super X11DPG-HGX2 |
| Processor - CPU | Dual Socket P (LGA 3647) Intel® Xeon® Scalable Processors, 3 UPI up to 10.4GT/s Support CPU TDP 205W |
| System Memory - Memory Capacity | 24 DIMM slots Up to 3TB 3DS ECC L/RDIMM, up to DDR4-2933MHz |
| System Memory - Memory Type | 2933/2666/2400/2133MHz ECC DDR4 RDIMM/LRDIMM |
| On-Board Devices - Chipset | Intel® C621 chipset |
| On-Board Devices - SATA | SATA3 (6Gbps) with RAID 0, 1, 5, 10 |
| On-Board Devices - IPMI | Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support |
| On-Board Devices - Network Controllers | Dual Port 10GBase-T from Intel X540 Ethernet Controller |
| Input Output - SATA | 6 SATA3 (6Gbps) ports |
| Input Output - LAN | 2 RJ45 10GBase-T LAN ports 1 RJ45 Dedicated IPMI LAN port |
| Input Output - USB | 2 USB 3.0 ports (front) |
| Input Output - Video | 1 VGA Connector |
| Chassis - Form Factor | 10U Rackmountable |
| Chassis - Model | CSE-1018G-R12KP |
| Expansion Slots - PCI-Express | 16 PCI-E 3.0 x16 for RDMA via IB EDR - supporting 16 V100 GPUs 2 PCI-E 3.0 x16 on motherboard |
| System Cooling - Fans | 6x 80mm Hot-swap PWM Fans 8x 92mm Hot-swap Fans |
| Power Supply | 6x 3000W Redundant Titanium Level Power Supplies with PMBus; 6x 3000W Redundant Titanium Level Power Supplies with PMBus; 6x 3000W Redundant Titanium Level Power Supplies with PMBus; 6x 3000W Redundant Titanium Level Power Supplies with PMBus |
| Power Supply - 12V | Max: 53.4A & Min: 0.3A (200-207Vac) Max: 55.6A & Min: 0.3A (208-240Vac) |
| Power Supply - Certification | Titanium Level |
| System BIOS - BIOS Type | AMI 32Mb SPI Flash ROM |
| Parts List - Items Included | Part Number; Description; Motherboard / Chassis; MBD-X11DPG-HGX2 MBD-X11DPG-HGX2-SW CSE-1018G-R12KP; Super X11DPG-HGX2 Motherboard HGX2 PCIe switch board CSE-1018G-R12KP Chassis; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Add-on Card / Module; AOM-HGX2-NVL-P; HGX2 NVLINK board,HF,RoHS; Add-on Card / Module; AOM-SBL-SAS3; AOM-SBL-SAS3; Backplane; BPN-GPU-1018G; Midplane for 10U CSE-1018G HGX-2 project,RoHS; Riser Card; RSC-G-66-HGX2; 1U LHS Passive GPU RSC w/ 2 PCI-Ex16 slots HGX-2 sys,HF,Rohs; Riser Card; RSC-G-A66; 1U LHS Active GPU Riser card with two PCI-E x16 Slots,HF,RoH; Heatsink / Retention; SNK-P0067PS; 1U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Heatsink / Retention; SNK-P0071VS; 1U Proprietary Passive CPU Heat Sink (124 mm Long) for SYS-2029BZ-HNR Series Servers (X11 2U4N 3UPI Big Twin); * Power Supply; PWS-3K01G-1R; AC-DC 3000W, Titanium efficiency output: 54Vdc/55.6A, 12Vsb/; * Backplane; BPN-PDB-1018G; 54V PDB for 10U CSE-1018G HGX-2 project, support 6x Delta 54Vdc/3KW PSU, RoHS; * Cable 1; CBL-0223L; BLADE PWS POWER CORD C19 to C20, PBF. 1.8m. 12AWG, 20A, 250V; * FAN 1; FAN-0196L4; 92x92x76 mm, 13.3K-12.2K RPM Counter-rotating Fan for HGX2 P; * FAN 2; FAN-0197L4; 80x80x80 mm, 12K-11.3K RPM Counter-rotating Fan for HGX2 Pro; * Front Panel; FPB-FP1018G; Front control board 4.59x2.59 inches for SC1018G,RoHS; * Drive Tray(s); MCP-220-00169-0B; Black hot swap tool-less 2.5; * Drive Tray(s); MCP-220-00170-0B; Black hot swap tool-less NVMe 2.5; * Rail Set; MCP-290-41803-0N; Fat twin F418 / F424 Static Rail set support 28-33.5 inch depth rail,RoHS/REACH,PBF; * Parts; MCP-620-00022-0N; Blade Server Front Blade Light Pipe for MB; Part Number; Description; Motherboard / Chassis; MBD-X11DPG-HGX2 MBD-X11DPG-HGX2-SW CSE-1018G-R12KP; Super X11DPG-HGX2 Motherboard HGX2 PCIe switch board CSE-1018G-R12KP Chassis; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Add-on Card / Module; AOM-HGX2-NVL-P; HGX2 NVLINK board,HF,RoHS; Add-on Card / Module; AOM-SBL-SAS3; AOM-SBL-SAS3; Backplane; BPN-GPU-1018G; Midplane for 10U CSE-1018G HGX-2 project,RoHS; Riser Card; RSC-G-66-HGX2; 1U LHS Passive GPU RSC w/ 2 PCI-Ex16 slots HGX-2 sys,HF,Rohs; Riser Card; RSC-G-A66; 1U LHS Active GPU Riser card with two PCI-E x16 Slots,HF,RoH; Heatsink / Retention; SNK-P0067PS; 1U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Heatsink / Retention; SNK-P0071VS; 1U Proprietary Passive CPU Heat Sink (124 mm Long) for SYS-2029BZ-HNR Series Servers (X11 2U4N 3UPI Big Twin); * Power Supply; PWS-3K01G-1R; AC-DC 3000W, Titanium efficiency output: 54Vdc/55.6A, 12Vsb/; * Backplane; BPN-PDB-1018G; 54V PDB for 10U CSE-1018G HGX-2 project, support 6x Delta 54Vdc/3KW PSU, RoHS; * Cable 1; CBL-0223L; BLADE PWS POWER CORD C19 to C20, PBF. 1.8m. 12AWG, 20A, 250V; * FAN 1; FAN-0196L4; 92x92x76 mm, 13.3K-12.2K RPM Counter-rotating Fan for HGX2 P; * FAN 2; FAN-0197L4; 80x80x80 mm, 12K-11.3K RPM Counter-rotating Fan for HGX2 Pro; * Front Panel; FPB-FP1018G; Front control board 4.59x2.59 inches for SC1018G,RoHS; * Drive Tray(s); MCP-220-00169-0B; Black hot swap tool-less 2.5; * Drive Tray(s); MCP-220-00170-0B; Black hot swap tool-less NVMe 2.5; * Rail Set; MCP-290-41803-0N; Fat twin F418 / F424 Static Rail set support 28-33.5 inch depth rail,RoHS/REACH,PBF; * Parts; MCP-620-00022-0N; Blade Server Front Blade Light Pipe for MB; Part Number; Description; Motherboard / Chassis; MBD-X11DPG-HGX2 MBD-X11DPG-HGX2-SW CSE-1018G-R12KP; Super X11DPG-HGX2 Motherboard HGX2 PCIe switch board CSE-1018G-R12KP Chassis; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Add-on Card / Module; AOM-HGX2-NVL-P; HGX2 NVLINK board,HF,RoHS; Add-on Card / Module; AOM-SBL-SAS3; AOM-SBL-SAS3; Backplane; BPN-GPU-1018G; Midplane for 10U CSE-1018G HGX-2 project,RoHS; Riser Card; RSC-G-66-HGX2; 1U LHS Passive GPU RSC w/ 2 PCI-Ex16 slots HGX-2 sys,HF,Rohs; Riser Card; RSC-G-A66; 1U LHS Active GPU Riser card with two PCI-E x16 Slots,HF,RoH; Heatsink / Retention; SNK-P0067PS; 1U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Heatsink / Retention; SNK-P0071VS; 1U Proprietary Passive CPU Heat Sink (124 mm Long) for SYS-2029BZ-HNR Series Servers (X11 2U4N 3UPI Big Twin); * Power Supply; PWS-3K01G-1R; AC-DC 3000W, Titanium efficiency output: 54Vdc/55.6A, 12Vsb/; * Backplane; BPN-PDB-1018G; 54V PDB for 10U CSE-1018G HGX-2 project, support 6x Delta 54Vdc/3KW PSU, RoHS; * Cable 1; CBL-0223L; BLADE PWS POWER CORD C19 to C20, PBF. 1.8m. 12AWG, 20A, 250V; * FAN 1; FAN-0196L4; 92x92x76 mm, 13.3K-12.2K RPM Counter-rotating Fan for HGX2 P; * FAN 2; FAN-0197L4; 80x80x80 mm, 12K-11.3K RPM Counter-rotating Fan for HGX2 Pro; * Front Panel; FPB-FP1018G; Front control board 4.59x2.59 inches for SC1018G,RoHS; * Drive Tray(s); MCP-220-00169-0B; Black hot swap tool-less 2.5; * Drive Tray(s); MCP-220-00170-0B; Black hot swap tool-less NVMe 2.5; * Rail Set; MCP-290-41803-0N; Fat twin F418 / F424 Static Rail set support 28-33.5 inch depth rail,RoHS/REACH,PBF; * Parts; MCP-620-00022-0N; Blade Server Front Blade Light Pipe for MB; Part Number; Description; Motherboard / Chassis; MBD-X11DPG-HGX2 MBD-X11DPG-HGX2-SW CSE-1018G-R12KP; Super X11DPG-HGX2 Motherboard HGX2 PCIe switch board CSE-1018G-R12KP Chassis; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Add-on Card / Module; AOM-HGX2-NVL-P; HGX2 NVLINK board,HF,RoHS; Add-on Card / Module; AOM-SBL-SAS3; AOM-SBL-SAS3; Backplane; BPN-GPU-1018G; Midplane for 10U CSE-1018G HGX-2 project,RoHS; Riser Card; RSC-G-66-HGX2; 1U LHS Passive GPU RSC w/ 2 PCI-Ex16 slots HGX-2 sys,HF,Rohs; Riser Card; RSC-G-A66; 1U LHS Active GPU Riser card with two PCI-E x16 Slots,HF,RoH; Heatsink / Retention; SNK-P0067PS; 1U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Heatsink / Retention; SNK-P0071VS; 1U Proprietary Passive CPU Heat Sink (124 mm Long) for SYS-2029BZ-HNR Series Servers (X11 2U4N 3UPI Big Twin); * Power Supply; PWS-3K01G-1R; AC-DC 3000W, Titanium efficiency output: 54Vdc/55.6A, 12Vsb/; * Backplane; BPN-PDB-1018G; 54V PDB for 10U CSE-1018G HGX-2 project, support 6x Delta 54Vdc/3KW PSU, RoHS; * Cable 1; CBL-0223L; BLADE PWS POWER CORD C19 to C20, PBF. 1.8m. 12AWG, 20A, 250V; * FAN 1; FAN-0196L4; 92x92x76 mm, 13.3K-12.2K RPM Counter-rotating Fan for HGX2 P; * FAN 2; FAN-0197L4; 80x80x80 mm, 12K-11.3K RPM Counter-rotating Fan for HGX2 Pro; * Front Panel; FPB-FP1018G; Front control board 4.59x2.59 inches for SC1018G,RoHS; * Drive Tray(s); MCP-220-00169-0B; Black hot swap tool-less 2.5; * Drive Tray(s); MCP-220-00170-0B; Black hot swap tool-less NVMe 2.5; * Rail Set; MCP-290-41803-0N; Fat twin F418 / F424 Static Rail set support 28-33.5 inch depth rail,RoHS/REACH,PBF; * Parts; MCP-620-00022-0N; Blade Server Front Blade Light Pipe for MB |
| Optional Parts List | Part Number; Description; NVMe RAID 1 (Require Intel VROC Key); AOC-SLG3-2M2 Tested M.2 List; Low Profile PCI-E x8 add-on card supports 2 PCI-E 3.0 x4 M-Key M.2 NVMe Modules NVMe M.2 Module; Network Card(s); AOC-MCX455A-ECAT-MLN; Mellanox ConnectX-4 VPI adapter card, EDR IB (100Gb/s) and 100GbE, single-port QSFP28, PCIe3.0 x16, tall bracket, ROHS R6; AOC-MCX456A-ECAT-MLN; Mellanox ConnectX-4 VPI adapter card, EDR IB (100Gb/s) and 100GbE, dual-port QSFP28, PCIe3.0 x16, tall bracket, ROHS R6; AOC-MCX515A-CCAT; Mellanox ConnectX-5 EN network interface card, 100GbE single-port QSFP28, PCIe3.0 x16, HF, RoHSket, HF, RoHS; AOC-MCX516A-CCAT; Mellanox ConnectX-5 EN network interface card, 100GbE dual-port QSFP28, PCIe3.0 x16, tall bracket, HF, RoHS; AOC-MCX555A-ECAT; Mellanox ConnectX-5 VPI adapter card, EDR IB (100Gb/s) and 100GbE, single-port QSFP28, PCIe3.0 x16, tall bracket, HF, RoHS; AOC-MCX556A-ECAT; Mellanox ConnectX-5 VPI adapter card, EDR IB (100Gb/s) and 100GbE, dual-port QSFP28, PCIe3.0 x16, tall bracket, HF, RoHS; TPM Security Module; AOM-TPM-9670V; SPI capable vertical TPM 2.0 provisioned for client,RoHS; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; NVMe RAID 1 (Require Intel VROC Key); AOC-SLG3-2M2 Tested M.2 List; Low Profile PCI-E x8 add-on card supports 2 PCI-E 3.0 x4 M-Key M.2 NVMe Modules NVMe M.2 Module; Network Card(s); AOC-MCX455A-ECAT-MLN; Mellanox ConnectX-4 VPI adapter card, EDR IB (100Gb/s) and 100GbE, single-port QSFP28, PCIe3.0 x16, tall bracket, ROHS R6; AOC-MCX456A-ECAT-MLN; Mellanox ConnectX-4 VPI adapter card, EDR IB (100Gb/s) and 100GbE, dual-port QSFP28, PCIe3.0 x16, tall bracket, ROHS R6; AOC-MCX515A-CCAT; Mellanox ConnectX-5 EN network interface card, 100GbE single-port QSFP28, PCIe3.0 x16, HF, RoHSket, HF, RoHS; AOC-MCX516A-CCAT; Mellanox ConnectX-5 EN network interface card, 100GbE dual-port QSFP28, PCIe3.0 x16, tall bracket, HF, RoHS; AOC-MCX555A-ECAT; Mellanox ConnectX-5 VPI adapter card, EDR IB (100Gb/s) and 100GbE, single-port QSFP28, PCIe3.0 x16, tall bracket, HF, RoHS; AOC-MCX556A-ECAT; Mellanox ConnectX-5 VPI adapter card, EDR IB (100Gb/s) and 100GbE, dual-port QSFP28, PCIe3.0 x16, tall bracket, HF, RoHS; TPM Security Module; AOM-TPM-9670V; SPI capable vertical TPM 2.0 provisioned for client,RoHS; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; NVMe RAID 1 (Require Intel VROC Key); AOC-SLG3-2M2 Tested M.2 List; Low Profile PCI-E x8 add-on card supports 2 PCI-E 3.0 x4 M-Key M.2 NVMe Modules NVMe M.2 Module; Network Card(s); AOC-MCX455A-ECAT-MLN; Mellanox ConnectX-4 VPI adapter card, EDR IB (100Gb/s) and 100GbE, single-port QSFP28, PCIe3.0 x16, tall bracket, ROHS R6; AOC-MCX456A-ECAT-MLN; Mellanox ConnectX-4 VPI adapter card, EDR IB (100Gb/s) and 100GbE, dual-port QSFP28, PCIe3.0 x16, tall bracket, ROHS R6; AOC-MCX515A-CCAT; Mellanox ConnectX-5 EN network interface card, 100GbE single-port QSFP28, PCIe3.0 x16, HF, RoHSket, HF, RoHS; AOC-MCX516A-CCAT; Mellanox ConnectX-5 EN network interface card, 100GbE dual-port QSFP28, PCIe3.0 x16, tall bracket, HF, RoHS; AOC-MCX555A-ECAT; Mellanox ConnectX-5 VPI adapter card, EDR IB (100Gb/s) and 100GbE, single-port QSFP28, PCIe3.0 x16, tall bracket, HF, RoHS; AOC-MCX556A-ECAT; Mellanox ConnectX-5 VPI adapter card, EDR IB (100Gb/s) and 100GbE, dual-port QSFP28, PCIe3.0 x16, tall bracket, HF, RoHS; TPM Security Module; AOM-TPM-9670V; SPI capable vertical TPM 2.0 provisioned for client,RoHS; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; NVMe RAID 1 (Require Intel VROC Key); AOC-SLG3-2M2 Tested M.2 List; Low Profile PCI-E x8 add-on card supports 2 PCI-E 3.0 x4 M-Key M.2 NVMe Modules NVMe M.2 Module; Network Card(s); AOC-MCX455A-ECAT-MLN; Mellanox ConnectX-4 VPI adapter card, EDR IB (100Gb/s) and 100GbE, single-port QSFP28, PCIe3.0 x16, tall bracket, ROHS R6; AOC-MCX456A-ECAT-MLN; Mellanox ConnectX-4 VPI adapter card, EDR IB (100Gb/s) and 100GbE, dual-port QSFP28, PCIe3.0 x16, tall bracket, ROHS R6; AOC-MCX515A-CCAT; Mellanox ConnectX-5 EN network interface card, 100GbE single-port QSFP28, PCIe3.0 x16, HF, RoHSket, HF, RoHS; AOC-MCX516A-CCAT; Mellanox ConnectX-5 EN network interface card, 100GbE dual-port QSFP28, PCIe3.0 x16, tall bracket, HF, RoHS; AOC-MCX555A-ECAT; Mellanox ConnectX-5 VPI adapter card, EDR IB (100Gb/s) and 100GbE, single-port QSFP28, PCIe3.0 x16, tall bracket, HF, RoHS; AOC-MCX556A-ECAT; Mellanox ConnectX-5 VPI adapter card, EDR IB (100Gb/s) and 100GbE, dual-port QSFP28, PCIe3.0 x16, tall bracket, HF, RoHS; TPM Security Module; AOM-TPM-9670V; SPI capable vertical TPM 2.0 provisioned for client,RoHS; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-DCMS-Single; DataCenter Management Package (per node license) |
| System BIOS - BIOS Features | Intel® Node Manager IPMI 2.0 KVM with dedicated LAN SSM , SPM , SUM SuperDoctor® 5 Watchdog |
| On-Board Devices - Graphics | ASPEED AST2500 BMC |
| Dimensions - Width | 17.8" (452mm) |
| Dimensions - Height | 17.2" (437mm) |
| Dimensions - Depth | 27.75" (705mm) |
| Dimensions - Weight | Net Weight: 298 lbs (135 kg) Gross Weight: 385 lbs (175 kg) |
| Dimensions - Available Colors | Black |
| Processor - Cores | Up to 28 Cores |
| Operating Environment - RoHS | RoHS Compliant |
| Operating Environment - Environmental Spec | Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F) Non-operating Temperature: -40°C to 60°C (-40°F to 140°F) Operating Relative Humidity: 10% to 85% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) |
| Drive Bays Storage - Hot-swap | 16 Hot-swap 2.5" NVMe drive bays * 6 Hot-swap 2.5" SATA3 drive bays |
| Drive Bays Storage - M2 | M.2 Interface: 2 PCI-E 3.0 x4 Form Factors: 2280, 22110 Key: M-Key |
| Power Supply - Total Output Power | 2883W with Input 200 - 207Vac 3000W with Input 208 - 240Vac |
| Power Supply - DimensionW x H x L | 68 x 40 x 430 mm |
| Power Supply - Input | 50-60Hz |
| Power Supply - 12Vsb | Max: 3A / Min: 0A |
| Power Supply - Output Type | Backplanes (gold finger) |
| Input Output - COM Port | 1 COM port (header) |
| GPU - Supported GPUs | 16 SXM Socket Based NVIDIA V100 Compatible GPU list |
| GPU - CPU-GPU Interconnect | PCI-E Gen 3 x16 Switch CPU-GPU Interconnect |
| GPU - GPU-GPU Interconnect | NVIDIA® NVLink™ with NVSwitch™ GPU-GPU Interconnect |
| Product SKUs - SYS-9029GP-TNVRT | SuperServer 9029GP-TNVRT ( Black ) |
| Drive Bays Storage - Note | * NVMe hot-swap feature doesn't work in Windows environment |
Отзывы
Загрузка отзывов...
Добавить отзыв
Оплачивайте покупки удобным способом. В интернет-магазине доступно 3 варианта оплаты:
- Наличные при самовывозе или доставке курьером. Специалист свяжется с вами в день доставки, чтобы уточнить время и заранее подготовить сдачу с любой купюры. Вы подписываете товаросопроводительные документы, вносите денежные средства, получаете товар и чек.
- Безналичный расчет при самовывозе или оформлении в интернет-магазине: карты МИР, Visa и MasterCard. Чтобы оплатить покупку, система перенаправит вас на сервер системы ASSIST. Здесь нужно ввести номер карты, срок действия и имя держателя.
- ЮMoney при онлайн-заказе. Для совершения покупки система перенаправит вас на страницу платежного сервиса. Здесь необходимо заполнить форму по инструкции.
Экономьте время на получении заказа. В интернет-магазине доступно 4 варианта доставки:
- Курьерская доставка работает с 9.00 до 19.00. Когда товар поступит на склад, курьерская служба свяжется для уточнения деталей. Специалист предложит выбрать удобное время доставки и уточнит адрес. Осмотрите упаковку на целостность и соответствие указанной комплектации.
- Самовывоз из магазина. Список торговых точек для выбора появится в корзине. Когда заказ поступит на склад, вам придет уведомление. Для получения заказа обратитесь к сотруднику в кассовой зоне и назовите номер.
- Постамат. Когда заказ поступит на точку, на ваш телефон или e-mail придет уникальный код. Заказ нужно оплатить в терминале постамата. Срок хранения — 3 дня.
- Почтовая доставка через почту России. Когда заказ придет в отделение, на ваш адрес придет извещение о посылке. Перед оплатой вы можете оценить состояние коробки: вес, целостность. Вскрывать коробку самостоятельно вы можете только после оплаты заказа. Один заказ может содержать не больше 10 позиций и его стоимость не должна превышать 100 000 р.