| Motherboard | Super X11DPFF-SN; Super X11DPFF-SN; Super X11DPFF-SN; Super X11DPFF-SN |
| On-Board Devices - Chipset | Intel® C621 chipset |
| On-Board Devices - SATA | SATA3 (6Gbps); RAID 0, 1, 5, 10 |
| On-Board Devices - IPMI | Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support |
| On-Board Devices - Network Controllers | Flexible networking via SIOM |
| PC Health Monitoring - FAN | Fans with tachometer monitoring Status monitor for speed control Pulse Width Modulated (PWM) fan connectors |
| PC Health Monitoring - Temperature | Monitoring for CPU and chassis environment Thermal Control for fan connectors |
| Chassis - Form Factor | 4U Rackmount |
| Chassis - Model | CSE-F418IF3-R2K20BP |
| Dimensions and Weight - Height | 6.96" (177mm) |
| Dimensions and Weight - Width | 17.63" (448mm) |
| Dimensions and Weight - Depth | 29" (737mm) |
| Dimensions and Weight - Package | 28.3" (W) x 15.0" (H) x 42.4" (D) |
| Dimensions and Weight - Weight | Net Weight: 150 lbs (68.04 kg) Gross Weight: 200 lbs (90.71 kg) |
| Dimensions and Weight - Available Colors | Black |
| Front Panel - Buttons | Power On/Off button UID button |
| Front Panel - LEDs | Power status LED Network activity LEDs Information LED (Fan failure, Overheat) |
| System Cooling - Fans | 8x 8cm 13.5k RPM rear fans per enclosure |
| Power Supply | 2200W Redundant Power Supplies with PMBus; 2200W Redundant Power Supplies with PMBus; 2200W Redundant Power Supplies with PMBus; 2200W Redundant Power Supplies with PMBus |
| Power Supply - 12V | Max: 100A / Min: 0A (100-127Vac) Max: 150A / Min: 0A (200-220Vac) Max: 165A / Min: 0A (220-230Vac) Max: 174.17A / Min: 0A (230-240Vac) Max: 183.3A / Min: 0A (220-240Vac) |
| Power Supply - Certification | Titanium Level [ Test Report ] |
| System BIOS - BIOS Type | 128Mb SPI Flash EEPROM with AMI BIOS |
| Parts List - Items Included | Part Number; Description; Motherboard / Chassis; MBD-X11DPFF-SNR CSE-F418IF3-R2K20BP; Super X11DPFF-SNR Motherboard 4U Chassis; Backplane; BPN-ADP-X11DPFF; Power adapter card for X11DPFF,RoHS; Cable 1; CBL-CDAT-0910; CBL,SGPIO,2X5F TO 2X5F,P2.54, 14CM, 24AWG,RoHS; Cable 2; CBL-PWCD-0578; PWCD,US,IEC60320 C14 TO C13,3FT,14AWG; Cable 3; CBL-PWEX-1020; PWEX,2X4F/P4.2 TO 2X4F/P4.2,10.5CM,16AWG,RoHS; Cable 4; CBL-PWEX-1020-11; PWEX,2X4F/P4.2 TO 2X4F/P4.2,10.5CM,16AWG,RoHS; Cable 5; CBL-SAST-0757; INT MINI SAS HD to SAS 29px2 + 8p 2x4(5,12V) GPU PWR BLK,50cm,22/30AWG,RoHS/REACH; Riser Card; RSC-P-6; RSC-P-6 (1U LHS TwinPro RSC with 1 PCI-Ex16),RoHS; Riser Card; RSC-R1UF-E16R; RSC-R1UF-E16R; Heatsink / Retention; SNK-P0067PS; 1U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Heatsink / Retention; SNK-P0067PSC; 1U Passive CPU Heat Sink with a 17-mm Wide Side Air Channel for X11 Purley Platform Equipped with a Narrow Retention Mechanism; * Power Supply; PWS-2K04A-1R; AC-DC 2000W, Titanium Level, Redundancy, 1U, PMBus 1.2, +12V/+5Vsb, 360x76x40mm,HF,RoHS/REACH; * Power Supply; PWS-2K20A-1R; 1U 2200W Redundant, Titanium, 76(W) X 40(H) X 336(L) mm; * Backplane; BPN-PDB-X11DPFF; Power Middleplane for X11 FIO Fattwin,RoHS; * Rail Set; MCP-290-41803-0N; Fat twin F418 / F424 Static Rail set support 28-33.5 inch depth rail,RoHS/REACH,PBF; Part Number; Description; Motherboard / Chassis; MBD-X11DPFF-SNR CSE-F418IF3-R2K20BP; Super X11DPFF-SNR Motherboard 4U Chassis; Backplane; BPN-ADP-X11DPFF; Power adapter card for X11DPFF,RoHS; Cable 1; CBL-CDAT-0910; CBL,SGPIO,2X5F TO 2X5F,P2.54, 14CM, 24AWG,RoHS; Cable 2; CBL-PWCD-0578; PWCD,US,IEC60320 C14 TO C13,3FT,14AWG; Cable 3; CBL-PWEX-1020; PWEX,2X4F/P4.2 TO 2X4F/P4.2,10.5CM,16AWG,RoHS; Cable 4; CBL-PWEX-1020-11; PWEX,2X4F/P4.2 TO 2X4F/P4.2,10.5CM,16AWG,RoHS; Cable 5; CBL-SAST-0757; INT MINI SAS HD to SAS 29px2 + 8p 2x4(5,12V) GPU PWR BLK,50cm,22/30AWG,RoHS/REACH; Riser Card; RSC-P-6; RSC-P-6 (1U LHS TwinPro RSC with 1 PCI-Ex16),RoHS; Riser Card; RSC-R1UF-E16R; RSC-R1UF-E16R; Heatsink / Retention; SNK-P0067PS; 1U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Heatsink / Retention; SNK-P0067PSC; 1U Passive CPU Heat Sink with a 17-mm Wide Side Air Channel for X11 Purley Platform Equipped with a Narrow Retention Mechanism; * Power Supply; PWS-2K04A-1R; AC-DC 2000W, Titanium Level, Redundancy, 1U, PMBus 1.2, +12V/+5Vsb, 360x76x40mm,HF,RoHS/REACH; * Power Supply; PWS-2K20A-1R; 1U 2200W Redundant, Titanium, 76(W) X 40(H) X 336(L) mm; * Backplane; BPN-PDB-X11DPFF; Power Middleplane for X11 FIO Fattwin,RoHS; * Rail Set; MCP-290-41803-0N; Fat twin F418 / F424 Static Rail set support 28-33.5 inch depth rail,RoHS/REACH,PBF; Part Number; Description; Motherboard / Chassis; MBD-X11DPFF-SNR CSE-F418IF3-R2K20BP; Super X11DPFF-SNR Motherboard 4U Chassis; Backplane; BPN-ADP-X11DPFF; Power adapter card for X11DPFF,RoHS; Cable 1; CBL-CDAT-0910; CBL,SGPIO,2X5F TO 2X5F,P2.54, 14CM, 24AWG,RoHS; Cable 2; CBL-PWCD-0578; PWCD,US,IEC60320 C14 TO C13,3FT,14AWG; Cable 3; CBL-PWEX-1020; PWEX,2X4F/P4.2 TO 2X4F/P4.2,10.5CM,16AWG,RoHS; Cable 4; CBL-PWEX-1020-11; PWEX,2X4F/P4.2 TO 2X4F/P4.2,10.5CM,16AWG,RoHS; Cable 5; CBL-SAST-0757; INT MINI SAS HD to SAS 29px2 + 8p 2x4(5,12V) GPU PWR BLK,50cm,22/30AWG,RoHS/REACH; Riser Card; RSC-P-6; RSC-P-6 (1U LHS TwinPro RSC with 1 PCI-Ex16),RoHS; Riser Card; RSC-R1UF-E16R; RSC-R1UF-E16R; Heatsink / Retention; SNK-P0067PS; 1U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Heatsink / Retention; SNK-P0067PSC; 1U Passive CPU Heat Sink with a 17-mm Wide Side Air Channel for X11 Purley Platform Equipped with a Narrow Retention Mechanism; * Power Supply; PWS-2K04A-1R; AC-DC 2000W, Titanium Level, Redundancy, 1U, PMBus 1.2, +12V/+5Vsb, 360x76x40mm,HF,RoHS/REACH; * Power Supply; PWS-2K20A-1R; 1U 2200W Redundant, Titanium, 76(W) X 40(H) X 336(L) mm; * Backplane; BPN-PDB-X11DPFF; Power Middleplane for X11 FIO Fattwin,RoHS; * Rail Set; MCP-290-41803-0N; Fat twin F418 / F424 Static Rail set support 28-33.5 inch depth rail,RoHS/REACH,PBF; Part Number; Description; Motherboard / Chassis; MBD-X11DPFF-SNR CSE-F418IF3-R2K20BP; Super X11DPFF-SNR Motherboard 4U Chassis; Backplane; BPN-ADP-X11DPFF; Power adapter card for X11DPFF,RoHS; Cable 1; CBL-CDAT-0910; CBL,SGPIO,2X5F TO 2X5F,P2.54, 14CM, 24AWG,RoHS; Cable 2; CBL-PWCD-0578; PWCD,US,IEC60320 C14 TO C13,3FT,14AWG; Cable 3; CBL-PWEX-1020; PWEX,2X4F/P4.2 TO 2X4F/P4.2,10.5CM,16AWG,RoHS; Cable 4; CBL-PWEX-1020-11; PWEX,2X4F/P4.2 TO 2X4F/P4.2,10.5CM,16AWG,RoHS; Cable 5; CBL-SAST-0757; INT MINI SAS HD to SAS 29px2 + 8p 2x4(5,12V) GPU PWR BLK,50cm,22/30AWG,RoHS/REACH; Riser Card; RSC-P-6; RSC-P-6 (1U LHS TwinPro RSC with 1 PCI-Ex16),RoHS; Riser Card; RSC-R1UF-E16R; RSC-R1UF-E16R; Heatsink / Retention; SNK-P0067PS; 1U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Heatsink / Retention; SNK-P0067PSC; 1U Passive CPU Heat Sink with a 17-mm Wide Side Air Channel for X11 Purley Platform Equipped with a Narrow Retention Mechanism; * Power Supply; PWS-2K04A-1R; AC-DC 2000W, Titanium Level, Redundancy, 1U, PMBus 1.2, +12V/+5Vsb, 360x76x40mm,HF,RoHS/REACH; * Power Supply; PWS-2K20A-1R; 1U 2200W Redundant, Titanium, 76(W) X 40(H) X 336(L) mm; * Backplane; BPN-PDB-X11DPFF; Power Middleplane for X11 FIO Fattwin,RoHS; * Rail Set; MCP-290-41803-0N; Fat twin F418 / F424 Static Rail set support 28-33.5 inch depth rail,RoHS/REACH,PBF |
| Optional Parts List | Part Number; Description; Connect 2x 2.5" NVMe Drive; CBL-SAST-0950; 1/node; 2x OcuLink v 1.0 to 2x PCIe SFF-8639 w/ Power, 35/57CM, 32/24/20 AWG; Connect 4x 2.5" NVMe Drives *Consult with Technical Support; CBL-SAST-0950 MCP-120-00107-0N; 2/node 1/node; 2x OcuLink v 1.0 to 2x PCIe SFF-8639 w/ Power, 35/57CM, 32/24/20 AWG Fixed tool-less 2x 2.5" internal HDD bracket (2nd HDD required screws); Connect 4x 2.5" SATA Drives Working Conditions: • CPU Watts: 165W or lower • Ambient Temp: 30°C or lower; CBL-SAST-0673 MCP-120-00107-0N; 1/node 1/node; MINI SAS HD-SAS 29Px4+2x4P x2,INT,47/47/57/57CM,22/30AWG Fixed tool-less 2x 2.5" internal HDD bracket (2nd HDD required screws); Connect 2x 2.5" SAS Drives; *Any Qualified LSI Card (Please refer to X11DPFF-SN Tested AOC List); 1/node; Connect 4x 2.5" SAS Drives Working Conditions: • CPU Watts: 125W or lower • Ambient Temp: 25°C or lower; CBL-SAST-0673 MCP-120-00107-0N Any Qualified LSI Card (Please refer to X11DPFF-SN Tested AOC List); 1/node 1/node 1/node; MINI SAS HD-SAS 29Px4+2x4P x2,INT,47/47/57/57CM,22/30AWG Fixed tool-less 2x 2.5" internal HDD bracket (2nd HDD required screws) -; SuperCap Kit; BTR-CV3108-TP2; 1/node; LSI 3108 CacheVault kit for SIOM based TwinPro, RoHS/REACH; RAID Card; AOC-S3108L-H8IR-16DD; LSI 3108 8 int 12Gb/s ports, 8xGen3, ROC - LP,16 HDD; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; Connect 2x 2.5" NVMe Drive; CBL-SAST-0950; 1/node; 2x OcuLink v 1.0 to 2x PCIe SFF-8639 w/ Power, 35/57CM, 32/24/20 AWG; Connect 4x 2.5" NVMe Drives *Consult with Technical Support; CBL-SAST-0950 MCP-120-00107-0N; 2/node 1/node; 2x OcuLink v 1.0 to 2x PCIe SFF-8639 w/ Power, 35/57CM, 32/24/20 AWG Fixed tool-less 2x 2.5" internal HDD bracket (2nd HDD required screws); Connect 4x 2.5" SATA Drives Working Conditions: • CPU Watts: 165W or lower • Ambient Temp: 30°C or lower; CBL-SAST-0673 MCP-120-00107-0N; 1/node 1/node; MINI SAS HD-SAS 29Px4+2x4P x2,INT,47/47/57/57CM,22/30AWG Fixed tool-less 2x 2.5" internal HDD bracket (2nd HDD required screws); Connect 2x 2.5" SAS Drives; *Any Qualified LSI Card (Please refer to X11DPFF-SN Tested AOC List); 1/node; Connect 4x 2.5" SAS Drives Working Conditions: • CPU Watts: 125W or lower • Ambient Temp: 25°C or lower; CBL-SAST-0673 MCP-120-00107-0N Any Qualified LSI Card (Please refer to X11DPFF-SN Tested AOC List); 1/node 1/node 1/node; MINI SAS HD-SAS 29Px4+2x4P x2,INT,47/47/57/57CM,22/30AWG Fixed tool-less 2x 2.5" internal HDD bracket (2nd HDD required screws) -; SuperCap Kit; BTR-CV3108-TP2; 1/node; LSI 3108 CacheVault kit for SIOM based TwinPro, RoHS/REACH; RAID Card; AOC-S3108L-H8IR-16DD; LSI 3108 8 int 12Gb/s ports, 8xGen3, ROC - LP,16 HDD; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; Connect 2x 2.5" NVMe Drive; CBL-SAST-0950; 1/node; 2x OcuLink v 1.0 to 2x PCIe SFF-8639 w/ Power, 35/57CM, 32/24/20 AWG; Connect 4x 2.5" NVMe Drives *Consult with Technical Support; CBL-SAST-0950 MCP-120-00107-0N; 2/node 1/node; 2x OcuLink v 1.0 to 2x PCIe SFF-8639 w/ Power, 35/57CM, 32/24/20 AWG Fixed tool-less 2x 2.5" internal HDD bracket (2nd HDD required screws); Connect 4x 2.5" SATA Drives Working Conditions: • CPU Watts: 165W or lower • Ambient Temp: 30°C or lower; CBL-SAST-0673 MCP-120-00107-0N; 1/node 1/node; MINI SAS HD-SAS 29Px4+2x4P x2,INT,47/47/57/57CM,22/30AWG Fixed tool-less 2x 2.5" internal HDD bracket (2nd HDD required screws); Connect 2x 2.5" SAS Drives; *Any Qualified LSI Card (Please refer to X11DPFF-SN Tested AOC List); 1/node; Connect 4x 2.5" SAS Drives Working Conditions: • CPU Watts: 125W or lower • Ambient Temp: 25°C or lower; CBL-SAST-0673 MCP-120-00107-0N Any Qualified LSI Card (Please refer to X11DPFF-SN Tested AOC List); 1/node 1/node 1/node; MINI SAS HD-SAS 29Px4+2x4P x2,INT,47/47/57/57CM,22/30AWG Fixed tool-less 2x 2.5" internal HDD bracket (2nd HDD required screws) -; SuperCap Kit; BTR-CV3108-TP2; 1/node; LSI 3108 CacheVault kit for SIOM based TwinPro, RoHS/REACH; RAID Card; AOC-S3108L-H8IR-16DD; LSI 3108 8 int 12Gb/s ports, 8xGen3, ROC - LP,16 HDD; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; Connect 2x 2.5" NVMe Drive; CBL-SAST-0950; 1/node; 2x OcuLink v 1.0 to 2x PCIe SFF-8639 w/ Power, 35/57CM, 32/24/20 AWG; Connect 4x 2.5" NVMe Drives *Consult with Technical Support; CBL-SAST-0950 MCP-120-00107-0N; 2/node 1/node; 2x OcuLink v 1.0 to 2x PCIe SFF-8639 w/ Power, 35/57CM, 32/24/20 AWG Fixed tool-less 2x 2.5" internal HDD bracket (2nd HDD required screws); Connect 4x 2.5" SATA Drives Working Conditions: • CPU Watts: 165W or lower • Ambient Temp: 30°C or lower; CBL-SAST-0673 MCP-120-00107-0N; 1/node 1/node; MINI SAS HD-SAS 29Px4+2x4P x2,INT,47/47/57/57CM,22/30AWG Fixed tool-less 2x 2.5" internal HDD bracket (2nd HDD required screws); Connect 2x 2.5" SAS Drives; *Any Qualified LSI Card (Please refer to X11DPFF-SN Tested AOC List); 1/node; Connect 4x 2.5" SAS Drives Working Conditions: • CPU Watts: 125W or lower • Ambient Temp: 25°C or lower; CBL-SAST-0673 MCP-120-00107-0N Any Qualified LSI Card (Please refer to X11DPFF-SN Tested AOC List); 1/node 1/node 1/node; MINI SAS HD-SAS 29Px4+2x4P x2,INT,47/47/57/57CM,22/30AWG Fixed tool-less 2x 2.5" internal HDD bracket (2nd HDD required screws) -; SuperCap Kit; BTR-CV3108-TP2; 1/node; LSI 3108 CacheVault kit for SIOM based TwinPro, RoHS/REACH; RAID Card; AOC-S3108L-H8IR-16DD; LSI 3108 8 int 12Gb/s ports, 8xGen3, ROC - LP,16 HDD; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license) |
| Management - Software | Intel® Node Manager IPMI 2.0 KVM with dedicated LAN SuperDoctor® 5 Watch Dog |
| Management - Power Configurations | ACPI Power Management |
| Power Supply - 5VSB | Max: 1A / Min: 0A |
| On-Board Devices - Graphics | ASPEED AST2500 BMC |
| Expansion Slots per node - PCI-Express | 1 PCI-E 3.0 x16 (Low-profile) 1 PCI-E 3.0 x8 (Low-profile) 1 PCI-E 3.0 x16 (SIOM) |
| Input Output per node - LAN | SIOM flexible Network card 1 RJ45 Dedicated IPMI LAN port (front) |
| PC Health Monitoring - CPU | Monitors for CPU Cores, Chipset Voltages, Memory. 4+1 Phase-switching voltage regulator |
| Operating Environment - RoHS | RoHS Compliant |
| Operating Environment - Environmental Spec | Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F) Non-operating Temperature: -40°C to 60°C (-40°F to 140°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) |
| Power Supply - DimensionW x H x L | 76 x 40 x 336 mm |
| Power Supply - Output Type | Backplanes (gold finger) |
| System Memory per Node - Memory Capacity | 12 DIMM slots Up to 3TB 3DS ECC DDR4-2933MHz † RDIMM/LRDIMM Supports Intel® Optane™ DCPMM †† |
| System Memory per Node - Memory Type | 2933 † /2666/2400/2133MHz ECC DDR4 RDIMM/LRDIMM |
| System Memory per Node - Note | † 2933MHz in two DIMMs per channel can be achieved by using memory purchased from Supermicro †† Cascade Lake only. Contact your Supermicro sales rep for more info. |
| Input Output per node - USB | 2 USB 3.0 ports (front) |
| Input Output per node - VGA | 1 VGA port (front) |
| Drive Bays per node - M2 | M.2 Interface: 2 SATA/PCI-E 3.0 x4, RAID 0 & 1 M.2 Form Factor: 2260, 2280, 22110 M.2 Key: M-Key |
| Power Supply - Total Output Power and Input | 1200W with Input 100-127Vac 1800W with Input 200-220Vac 1980W with Input 220-230Vac 2090W with Input 230-240Vac 2200W with Input 220-240Vac (for UL/cUL use only) 2090W with Input 230-240Vdc (for CCC only) |
| Power Supply - AC Input Frequency | 50-60Hz |
| Processor per Node - CPU | Dual Socket P (LGA 3647) 2nd Gen Intel® Xeon® Scalable Processors and Intel® Xeon® Scalable Processors ‡ , Dual UPI up to 10.4GT/s Support CPU TDP 70-165W with IVR |
| Processor per Node - Cores | Up to 28 Cores |
| Processor per Node - Note | ‡ BIOS version 3.2 or above is required to support 2nd Gen Intel® Xeon® Scalable processors (codenamed Cascade Lake-R) |
| Product SKUs - SYS-F619P2-FT | SuperServer F619P2-FT+ ( Black ) |
| Drive Bays per node - Fixed | 2 or 4 Fixed 2.5" SATA3/NVMe drive bays |
Отзывы
Загрузка отзывов...
Добавить отзыв
Оплачивайте покупки удобным способом. В интернет-магазине доступно 3 варианта оплаты:
- Наличные при самовывозе или доставке курьером. Специалист свяжется с вами в день доставки, чтобы уточнить время и заранее подготовить сдачу с любой купюры. Вы подписываете товаросопроводительные документы, вносите денежные средства, получаете товар и чек.
- Безналичный расчет при самовывозе или оформлении в интернет-магазине: карты МИР, Visa и MasterCard. Чтобы оплатить покупку, система перенаправит вас на сервер системы ASSIST. Здесь нужно ввести номер карты, срок действия и имя держателя.
- ЮMoney при онлайн-заказе. Для совершения покупки система перенаправит вас на страницу платежного сервиса. Здесь необходимо заполнить форму по инструкции.
Экономьте время на получении заказа. В интернет-магазине доступно 4 варианта доставки:
- Курьерская доставка работает с 9.00 до 19.00. Когда товар поступит на склад, курьерская служба свяжется для уточнения деталей. Специалист предложит выбрать удобное время доставки и уточнит адрес. Осмотрите упаковку на целостность и соответствие указанной комплектации.
- Самовывоз из магазина. Список торговых точек для выбора появится в корзине. Когда заказ поступит на склад, вам придет уведомление. Для получения заказа обратитесь к сотруднику в кассовой зоне и назовите номер.
- Постамат. Когда заказ поступит на точку, на ваш телефон или e-mail придет уникальный код. Заказ нужно оплатить в терминале постамата. Срок хранения — 3 дня.
- Почтовая доставка через почту России. Когда заказ придет в отделение, на ваш адрес придет извещение о посылке. Перед оплатой вы можете оценить состояние коробки: вес, целостность. Вскрывать коробку самостоятельно вы можете только после оплаты заказа. Один заказ может содержать не больше 10 позиций и его стоимость не должна превышать 100 000 р.