| Motherboard | Super X11DPU-V; Super X11DPU-V; Super X11DPU-V; Super X11DPU-V |
| Processor - CPU | Dual Socket P (LGA 3647) 2nd Gen Intel® Xeon® Scalable Processors and Intel® Xeon® Scalable Processors, Dual UPI up to 10.4GT/s Support CPU TDP 70-150W |
| Processor - Note | * Refer to NEBS Tested Parts List for NEBS compliant CPUs supported |
| System Memory - Memory Capacity | 24 DIMM slots Up to 2TB 3DS ECC DDR4-2933MHz † RDIMM |
| System Memory - Memory Type | 2933 † /2666/2400/2133MHz ECC DDR4 RDIMM |
| On-Board Devices - Chipset | Intel® C621 chipset |
| On-Board Devices - SATA | SATA3 (6Gbps) |
| On-Board Devices - IPMI | Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support |
| Input Output - SATA | 6 SATA3 (6Gbps) ports |
| Input Output - LAN | Networking options provided via Ultra Riser card 1 RJ45 Dedicated IPMI LAN port |
| Input Output - USB | 2 USB 3.0 ports (rear) |
| Input Output - Video | 1 VGA port |
| PC Health Monitoring - FAN | Fans with tachometer monitoring Status monitor for speed control Pulse Width Modulated (PWM) fan connectors |
| PC Health Monitoring - Temperature | Monitoring for CPU and chassis environment Thermal Control for fan connectors |
| Chassis - Form Factor | 1U Rackmount |
| Chassis - Model | CSE-119UHTS-R1K62HP-NEBS |
| Dimensions and Weight - Height | 1.7" (43mm) |
| Dimensions and Weight - Width | 17.2" (437mm) |
| Dimensions and Weight - Depth | 29.1" (739mm) |
| Front Panel - Buttons | Power On/Off button System UID button |
| Front Panel - LEDs | Power LED Hard drive activity LED Network activity LEDs UID LED |
| Expansion Slots - PCI-Express | 2 PCI-E 3.0 x16 (FH, 10.5"L) 1 PCI-E 3.0 x8 (LP) 1 Internal PCI-E 3.0 |
| System Cooling - Fans | 8 Heavy duty fans with optimal fan speed control |
| Power Supply | 1600W Redundant Power Supplies with PMBus; 1600W Redundant Power Supplies with PMBus; 1600W Redundant Power Supplies with PMBus; 1600W Redundant Power Supplies with PMBus |
| Power Supply - 12V | Max: 83.3A / Min: 0A (100-127Vac) Max: 133A / Min: 0A (200-240Vac) |
| Power Supply - Certification | Titanium Level [ Test Report ] |
| System BIOS - BIOS Type | AMI 32Mb SPI Flash ROM |
| Parts List - Items Included | Part Number; Description; Motherboard / Chassis; MBD-X11DPU-V CSE-119UHTS-R1K62HP-NEBS; Super X11DPU-V Motherboard CSE-119UHTS-R1K62HP-NEBS; Backplane; BPN-SAS3-119A-N12; 1U Hybrid BPN for 12x2.5"; SAS3/SATA3/NVMe Storage Devices; Cable 1; CBL-CDAT-0190; CBL,FRONT CNTL,20 TO 20 PIN,RA,RND TUBE,30CM,28AWG; Cable 2; CBL-PWEX-0781; PWYCB,2X4F/GPU-White to TWO 2X2F,P4.2, (5,12V),65/65CM,18AWG,RoHS; Cable 3; CBL-PWEX-1067; PWEX,2X2F/P4.2 TO 2x4F/P4.2,BLK*2,YEL*1,RED*1,61CM,16AWG; Cable 5; CBL-SAST-0655; (SATA 8-11) MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,47CM,SB,30AWG; Cable 6; CBL-SAST-0656; (SATA 4-7) MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,39CM,SB,30AWG; Cable 7; CBL-SAST-0657; (SATA 0-3) MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,55CM,SB,30AWG; Cable 8; CBL-SAST-0822-1; (NVMe 0-1) SLIMLINE x8 (RE) to 2x Oculink x4, 63/63CM,85 OHM; Cable 9; CBL-SAST-1149-85; (NVMe 4.5) SLIMLINE SAS x8 (RE) to 2x Oculink x4,INT, 49CM, 85 OHM; Cable 10; CBL-SAST-1154-85; (NVMe 2-3) SLIMLINE x8 (RE) to 2x Oculink x4,INT, 54CM, 85 OHM; Drive Tray(s); MCP-220-00178-0B; 2.5 thin profile drive tray, Orange tab (for hotswap NVMe drive), for SC119UH; Drive Tray(s); MCP-220-00187-0B; 2.5 thin profile drive tray, standard color tab, for SC119UH; Air Shroud; MCP-310-11601-0B; (CPU2) Mylar air shroud for SC116U (X11 24DIMM, left side); Air Shroud; MCP-310-11906-0B; (CPU1) Right side air shroud with foam air block; Riser Card; RSC-R1UW-2E16; 1U LHS WIO Riser card with two PCI-E x16 slots; Riser Card; RSC-R1UW-E8R; 1U RHS WIO Riser card with one PCI-E x8 slot; Heatsink / Retention; SNK-P0067PS; 1U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; * Power Supply; PWS-1K62A-1R; AC-DC 1600W, Titanium Level, Redundancy, 1U, DC Output: +12V and +12Vs, 203 x 73.5 x 40 mm, AC Input: 90 - 264 VAC/47-63Hz, PMBus 1.2 with DSP controller,HF,RoHS/REACH; * Cable 10; CBL-CDAT-0218; CBL,CNTL PANEL CONVERTER,FOR 809H and CSE119UH,FFC,20PIN,15C; * Cable 11; CBL-CUSB-0996; USB 3.0(F) Type A, RA to USB3.0 20pin,60CM,26/30AWG,RoHS; * FAN 1; FAN-0163L4; 40x40x56 mm, 23.3K-20.3K RPM, Counter-rotating Fan/td>; * Front Panel; FPB-FP119UH; Front control board for 119UHTS 1U Ultra; * Rear Window; MCP-240-81916-0N; Rear window for SC819U, 119U tool-less chassis (No opening); * Rail Set; MCP-290-00102-0N; Outer rail, quick-release type, 25.6\" to 33.05\"; * Rail Set; MCP-290-00112-0N; Inner rail, extension, long (quick) for 1U 17.2; * Rail Set; MCP-290-00120-0N; Inner rail, front, quick-release type (thumb screw appiled); * Air Shroud; MCP-310-81905-0B; Plastic air shroud for SC819U, 119U, 829U, 219U (PWS),RoHS/REACH; Part Number; Description; Motherboard / Chassis; MBD-X11DPU-V CSE-119UHTS-R1K62HP-NEBS; Super X11DPU-V Motherboard CSE-119UHTS-R1K62HP-NEBS; Backplane; BPN-SAS3-119A-N12; 1U Hybrid BPN for 12x2.5"; SAS3/SATA3/NVMe Storage Devices; Cable 1; CBL-CDAT-0190; CBL,FRONT CNTL,20 TO 20 PIN,RA,RND TUBE,30CM,28AWG; Cable 2; CBL-PWEX-0781; PWYCB,2X4F/GPU-White to TWO 2X2F,P4.2, (5,12V),65/65CM,18AWG,RoHS; Cable 3; CBL-PWEX-1067; PWEX,2X2F/P4.2 TO 2x4F/P4.2,BLK*2,YEL*1,RED*1,61CM,16AWG; Cable 5; CBL-SAST-0655; (SATA 8-11) MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,47CM,SB,30AWG; Cable 6; CBL-SAST-0656; (SATA 4-7) MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,39CM,SB,30AWG; Cable 7; CBL-SAST-0657; (SATA 0-3) MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,55CM,SB,30AWG; Cable 8; CBL-SAST-0822-1; (NVMe 0-1) SLIMLINE x8 (RE) to 2x Oculink x4, 63/63CM,85 OHM; Cable 9; CBL-SAST-1149-85; (NVMe 4.5) SLIMLINE SAS x8 (RE) to 2x Oculink x4,INT, 49CM, 85 OHM; Cable 10; CBL-SAST-1154-85; (NVMe 2-3) SLIMLINE x8 (RE) to 2x Oculink x4,INT, 54CM, 85 OHM; Drive Tray(s); MCP-220-00178-0B; 2.5 thin profile drive tray, Orange tab (for hotswap NVMe drive), for SC119UH; Drive Tray(s); MCP-220-00187-0B; 2.5 thin profile drive tray, standard color tab, for SC119UH; Air Shroud; MCP-310-11601-0B; (CPU2) Mylar air shroud for SC116U (X11 24DIMM, left side); Air Shroud; MCP-310-11906-0B; (CPU1) Right side air shroud with foam air block; Riser Card; RSC-R1UW-2E16; 1U LHS WIO Riser card with two PCI-E x16 slots; Riser Card; RSC-R1UW-E8R; 1U RHS WIO Riser card with one PCI-E x8 slot; Heatsink / Retention; SNK-P0067PS; 1U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; * Power Supply; PWS-1K62A-1R; AC-DC 1600W, Titanium Level, Redundancy, 1U, DC Output: +12V and +12Vs, 203 x 73.5 x 40 mm, AC Input: 90 - 264 VAC/47-63Hz, PMBus 1.2 with DSP controller,HF,RoHS/REACH; * Cable 10; CBL-CDAT-0218; CBL,CNTL PANEL CONVERTER,FOR 809H and CSE119UH,FFC,20PIN,15C; * Cable 11; CBL-CUSB-0996; USB 3.0(F) Type A, RA to USB3.0 20pin,60CM,26/30AWG,RoHS; * FAN 1; FAN-0163L4; 40x40x56 mm, 23.3K-20.3K RPM, Counter-rotating Fan/td>; * Front Panel; FPB-FP119UH; Front control board for 119UHTS 1U Ultra; * Rear Window; MCP-240-81916-0N; Rear window for SC819U, 119U tool-less chassis (No opening); * Rail Set; MCP-290-00102-0N; Outer rail, quick-release type, 25.6\" to 33.05\"; * Rail Set; MCP-290-00112-0N; Inner rail, extension, long (quick) for 1U 17.2; * Rail Set; MCP-290-00120-0N; Inner rail, front, quick-release type (thumb screw appiled); * Air Shroud; MCP-310-81905-0B; Plastic air shroud for SC819U, 119U, 829U, 219U (PWS),RoHS/REACH; Part Number; Description; Motherboard / Chassis; MBD-X11DPU-V CSE-119UHTS-R1K62HP-NEBS; Super X11DPU-V Motherboard CSE-119UHTS-R1K62HP-NEBS; Backplane; BPN-SAS3-119A-N12; 1U Hybrid BPN for 12x2.5"; SAS3/SATA3/NVMe Storage Devices; Cable 1; CBL-CDAT-0190; CBL,FRONT CNTL,20 TO 20 PIN,RA,RND TUBE,30CM,28AWG; Cable 2; CBL-PWEX-0781; PWYCB,2X4F/GPU-White to TWO 2X2F,P4.2, (5,12V),65/65CM,18AWG,RoHS; Cable 3; CBL-PWEX-1067; PWEX,2X2F/P4.2 TO 2x4F/P4.2,BLK*2,YEL*1,RED*1,61CM,16AWG; Cable 5; CBL-SAST-0655; (SATA 8-11) MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,47CM,SB,30AWG; Cable 6; CBL-SAST-0656; (SATA 4-7) MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,39CM,SB,30AWG; Cable 7; CBL-SAST-0657; (SATA 0-3) MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,55CM,SB,30AWG; Cable 8; CBL-SAST-0822-1; (NVMe 0-1) SLIMLINE x8 (RE) to 2x Oculink x4, 63/63CM,85 OHM; Cable 9; CBL-SAST-1149-85; (NVMe 4.5) SLIMLINE SAS x8 (RE) to 2x Oculink x4,INT, 49CM, 85 OHM; Cable 10; CBL-SAST-1154-85; (NVMe 2-3) SLIMLINE x8 (RE) to 2x Oculink x4,INT, 54CM, 85 OHM; Drive Tray(s); MCP-220-00178-0B; 2.5 thin profile drive tray, Orange tab (for hotswap NVMe drive), for SC119UH; Drive Tray(s); MCP-220-00187-0B; 2.5 thin profile drive tray, standard color tab, for SC119UH; Air Shroud; MCP-310-11601-0B; (CPU2) Mylar air shroud for SC116U (X11 24DIMM, left side); Air Shroud; MCP-310-11906-0B; (CPU1) Right side air shroud with foam air block; Riser Card; RSC-R1UW-2E16; 1U LHS WIO Riser card with two PCI-E x16 slots; Riser Card; RSC-R1UW-E8R; 1U RHS WIO Riser card with one PCI-E x8 slot; Heatsink / Retention; SNK-P0067PS; 1U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; * Power Supply; PWS-1K62A-1R; AC-DC 1600W, Titanium Level, Redundancy, 1U, DC Output: +12V and +12Vs, 203 x 73.5 x 40 mm, AC Input: 90 - 264 VAC/47-63Hz, PMBus 1.2 with DSP controller,HF,RoHS/REACH; * Cable 10; CBL-CDAT-0218; CBL,CNTL PANEL CONVERTER,FOR 809H and CSE119UH,FFC,20PIN,15C; * Cable 11; CBL-CUSB-0996; USB 3.0(F) Type A, RA to USB3.0 20pin,60CM,26/30AWG,RoHS; * FAN 1; FAN-0163L4; 40x40x56 mm, 23.3K-20.3K RPM, Counter-rotating Fan/td>; * Front Panel; FPB-FP119UH; Front control board for 119UHTS 1U Ultra; * Rear Window; MCP-240-81916-0N; Rear window for SC819U, 119U tool-less chassis (No opening); * Rail Set; MCP-290-00102-0N; Outer rail, quick-release type, 25.6\" to 33.05\"; * Rail Set; MCP-290-00112-0N; Inner rail, extension, long (quick) for 1U 17.2; * Rail Set; MCP-290-00120-0N; Inner rail, front, quick-release type (thumb screw appiled); * Air Shroud; MCP-310-81905-0B; Plastic air shroud for SC819U, 119U, 829U, 219U (PWS),RoHS/REACH; Part Number; Description; Motherboard / Chassis; MBD-X11DPU-V CSE-119UHTS-R1K62HP-NEBS; Super X11DPU-V Motherboard CSE-119UHTS-R1K62HP-NEBS; Backplane; BPN-SAS3-119A-N12; 1U Hybrid BPN for 12x2.5"; SAS3/SATA3/NVMe Storage Devices; Cable 1; CBL-CDAT-0190; CBL,FRONT CNTL,20 TO 20 PIN,RA,RND TUBE,30CM,28AWG; Cable 2; CBL-PWEX-0781; PWYCB,2X4F/GPU-White to TWO 2X2F,P4.2, (5,12V),65/65CM,18AWG,RoHS; Cable 3; CBL-PWEX-1067; PWEX,2X2F/P4.2 TO 2x4F/P4.2,BLK*2,YEL*1,RED*1,61CM,16AWG; Cable 5; CBL-SAST-0655; (SATA 8-11) MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,47CM,SB,30AWG; Cable 6; CBL-SAST-0656; (SATA 4-7) MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,39CM,SB,30AWG; Cable 7; CBL-SAST-0657; (SATA 0-3) MINI SAS HD(ST)-MINI SAS(RA-RS EXIT),6G,INT,55CM,SB,30AWG; Cable 8; CBL-SAST-0822-1; (NVMe 0-1) SLIMLINE x8 (RE) to 2x Oculink x4, 63/63CM,85 OHM; Cable 9; CBL-SAST-1149-85; (NVMe 4.5) SLIMLINE SAS x8 (RE) to 2x Oculink x4,INT, 49CM, 85 OHM; Cable 10; CBL-SAST-1154-85; (NVMe 2-3) SLIMLINE x8 (RE) to 2x Oculink x4,INT, 54CM, 85 OHM; Drive Tray(s); MCP-220-00178-0B; 2.5 thin profile drive tray, Orange tab (for hotswap NVMe drive), for SC119UH; Drive Tray(s); MCP-220-00187-0B; 2.5 thin profile drive tray, standard color tab, for SC119UH; Air Shroud; MCP-310-11601-0B; (CPU2) Mylar air shroud for SC116U (X11 24DIMM, left side); Air Shroud; MCP-310-11906-0B; (CPU1) Right side air shroud with foam air block; Riser Card; RSC-R1UW-2E16; 1U LHS WIO Riser card with two PCI-E x16 slots; Riser Card; RSC-R1UW-E8R; 1U RHS WIO Riser card with one PCI-E x8 slot; Heatsink / Retention; SNK-P0067PS; 1U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism; * Power Supply; PWS-1K62A-1R; AC-DC 1600W, Titanium Level, Redundancy, 1U, DC Output: +12V and +12Vs, 203 x 73.5 x 40 mm, AC Input: 90 - 264 VAC/47-63Hz, PMBus 1.2 with DSP controller,HF,RoHS/REACH; * Cable 10; CBL-CDAT-0218; CBL,CNTL PANEL CONVERTER,FOR 809H and CSE119UH,FFC,20PIN,15C; * Cable 11; CBL-CUSB-0996; USB 3.0(F) Type A, RA to USB3.0 20pin,60CM,26/30AWG,RoHS; * FAN 1; FAN-0163L4; 40x40x56 mm, 23.3K-20.3K RPM, Counter-rotating Fan/td>; * Front Panel; FPB-FP119UH; Front control board for 119UHTS 1U Ultra; * Rear Window; MCP-240-81916-0N; Rear window for SC819U, 119U tool-less chassis (No opening); * Rail Set; MCP-290-00102-0N; Outer rail, quick-release type, 25.6\" to 33.05\"; * Rail Set; MCP-290-00112-0N; Inner rail, extension, long (quick) for 1U 17.2; * Rail Set; MCP-290-00120-0N; Inner rail, front, quick-release type (thumb screw appiled); * Air Shroud; MCP-310-81905-0B; Plastic air shroud for SC819U, 119U, 829U, 219U (PWS),RoHS/REACH |
| Input Output - SAS | 8 SAS optional via AOC-S3108L-H8IR-16DD |
| Management - Software | Intel® Node Manager Redfish API IPMI 2.0 KVM with dedicated LAN NMI SSM , SPM , SUM SuperDoctor® 5 |
| Management - Power Configurations | ACPI Power Management |
| Input Output - DOM | 2 Super DOM (Disk on Module) ports |
| On-Board Devices - Graphics | ASPEED AST2500 BMC |
| PC Health Monitoring - CPU | Monitors for CPU Cores, Chipset Voltages, Memory. 4+1 Phase-switching voltage regulator |
| Dimensions and Weight - Gross Weight | 48 lbs (21.8 kg) |
| Processor - Cores | Up to 24 Cores |
| System Memory - Note | † 2933MHz in two DIMMs per channel can be achieved by using memory purchased from Supermicro * Refer to NEBS Tested Parts List for NEBS compliant memory modules supported |
| Operating Environment - RoHS | RoHS Compliant |
| Operating Environment - Environmental Spec | Operating Temperature: Continuous: 5°C ~ 40°C (41°F ~ 104°F) Short term: -5°C ~ 55°C (23°F ~ 131°F) Non-operating Temperature: -40°C to 70°C (-40°F to 158°F) Operating Relative Humidity: 5% to 85% with excursions of 5% to 93% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) |
| On-Board Devices - Network Connectivity | Networking options provided via Ultra Riser card |
| Input Output - NVMe | 6 NVMe/SATA ports (NVMe from CPU 1) |
| Input Output - Serial Port | 1 Serial header |
| Dimensions and Weight - Available Color | Black |
| Drive Bays Storage - Hot-swap | 12 Hot-swap 2.5" drive bays, 6 NVMe/SATA ports (NVMe from CPU1) and 6 SATA ports Optional SAS support via AOC-S3108L-H8IR-16DD |
| System Cooling - Air Shroud | 1 Air Shroud |
| Power Supply - Total Output Power | 1000W: 100 - 127Vac 1600W: 200 - 240Vac |
| Power Supply - DimensionW x H x L | 73.5 x 40 x 203 mm |
| Power Supply - Input | 100-127Vac / 13 - 9A / 50-60Hz 200-240Vac / 10 - 8A / 50-60Hz |
| Power Supply - 12Vsb | Max: 2.1A / Min: 0A |
| Power Supply - Output Type | 25 Pairs Gold Finger Connector |
| Drive Bays Storage - Note | Refer to NEBS Tested Parts List for NEBS compliant drives supported |
| Product SKUs - SYS-1029U-TN12RV-NEBS | SuperServer 1029U-TN12RV-NEBS ( Black ) |
| NEBS Tested Parts List | Part Number; Description; P4X-CLX6230R-SRGZA; Intel Xeon Gold 6230R Processor, 26 Cores, 2.10GHz, 36MB, 150W; Memory; MEM-DR464L-CL01-ER29 MEM-DR464L-HL02-ER29 MEM-DR432L-HL01-ER29 MEM-DR432L-SL01-ER29 MEM-DR432L-CL01-ER29 MEM-DR416L-CL01-ER29 MEM-DR416L-HL04-ER29; 64GB, DDR4-2933, RDIMM, Micron 64GB, DDR4-2933, RDIMM, Hynix 32GB, DDR4-2933, RDIMM, Hynix 32GB, DDR4-2933, RDIMM, Samsung 32GB, DDR4-2933, RDIMM, Micron 16GB, DDR4-2933, RDIMM, Micron 16GB, DDR4-2933, RDIMM, Hynix; NVMe SSD; HDS-2VD-MTFDHAL11TTCW1AR HDS-SUN0-MZWLL6T4HMLA05 HDS-S2T1-MZ7LH3T8HMLT05 HDS-SUN1-MZQLB3T8HALS07 HDS-IUN2-SSDPE2KX020T8 HDS-IUN0-SSDPE2KE016T8 HDS-MMN-MTFDHBA256TCK1AS; 11TB, Micron 9200 ECO, <1 DWPD 6.4TB, Samsung PM1725B, 3 DWPD 3.84TB, Samsung PM883, 1.3 DWPD 3.84 TB, Samsung PM983, 1.3 DWPD 2TB, Intel P4510, 1 DWPD 1.6TB, Intel P4610, 3 DWPD Micron 2200 256GB NVMe PCIe3.0x4 TLC M.2 22x80mm; Riser Card; RSC-UMR-8 RSC-R1UW-2E16 RSC-R1UW-E8R; 1U Ultra RHS Riser Card with 1 PCIE/SATA Hybrid M.2 &1 PCIE 1U LHS WIO Riser card with two PCI-E x16 slots 1U RHS WIO Riser card with one PCI-E x8 slot; SATA SSD; HDS-I2T0-SSDSC2KG038T8 HDS-I2T0-SSDSC2KB480G8; 3.8TB, Intel D3-S4610, 3 DWPD 480GB, Intel D3-S4510, <2 DWPD; SAS SSD; HDS-H2A1-WUSTR1548ASS200 HDS-X2A-XS400ME70004; 480GB, WDC/HGST Ultrastar SS530, 1 DWPD 400GB, Seagate Lange, 10 DWPD; Storage Control Card and Cable(s); AOC-S3108L-H8iR-16DD & 2x CBL-SAST-0593; Std LP, 8 internal ports, 12Gb/s per port- Gen3, 240HDD, RAID 0, 1, 5, 6, 10, 50, 60; MINI SAS HD,12G,INT,60CM,30AWG; Network Card(s); AOC-S25G-m2S AOC-S100G-M2C; Standard LP, 2x 25GbE SFP28, Mellanox ConnectX-4 LX EN Standard LP, 2x 100GbE QSFP28, Mellanox ConnectX-4 LX EN; TPM security module; AOM-TPM-9670H-S; TCG 2.0 compliant trusted platform module (TPM), Horizontal FF; Ultra Riser Card; AOC-URN4-m2TS & MCP-240-81915-0N AOC-URN4-b2XT & MCP-240-81909-0N AOC-URN4; 2-port 25GbE SFP28, Mellanox CX-4 Lx EN 2-port 10GbE RJ45, Broadcom BCM57416 No Onboard NIC; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; P4X-CLX6230R-SRGZA; Intel Xeon Gold 6230R Processor, 26 Cores, 2.10GHz, 36MB, 150W; Memory; MEM-DR464L-CL01-ER29 MEM-DR464L-HL02-ER29 MEM-DR432L-HL01-ER29 MEM-DR432L-SL01-ER29 MEM-DR432L-CL01-ER29 MEM-DR416L-CL01-ER29 MEM-DR416L-HL04-ER29; 64GB, DDR4-2933, RDIMM, Micron 64GB, DDR4-2933, RDIMM, Hynix 32GB, DDR4-2933, RDIMM, Hynix 32GB, DDR4-2933, RDIMM, Samsung 32GB, DDR4-2933, RDIMM, Micron 16GB, DDR4-2933, RDIMM, Micron 16GB, DDR4-2933, RDIMM, Hynix; NVMe SSD; HDS-2VD-MTFDHAL11TTCW1AR HDS-SUN0-MZWLL6T4HMLA05 HDS-S2T1-MZ7LH3T8HMLT05 HDS-SUN1-MZQLB3T8HALS07 HDS-IUN2-SSDPE2KX020T8 HDS-IUN0-SSDPE2KE016T8 HDS-MMN-MTFDHBA256TCK1AS; 11TB, Micron 9200 ECO, <1 DWPD 6.4TB, Samsung PM1725B, 3 DWPD 3.84TB, Samsung PM883, 1.3 DWPD 3.84 TB, Samsung PM983, 1.3 DWPD 2TB, Intel P4510, 1 DWPD 1.6TB, Intel P4610, 3 DWPD Micron 2200 256GB NVMe PCIe3.0x4 TLC M.2 22x80mm; Riser Card; RSC-UMR-8 RSC-R1UW-2E16 RSC-R1UW-E8R; 1U Ultra RHS Riser Card with 1 PCIE/SATA Hybrid M.2 &1 PCIE 1U LHS WIO Riser card with two PCI-E x16 slots 1U RHS WIO Riser card with one PCI-E x8 slot; SATA SSD; HDS-I2T0-SSDSC2KG038T8 HDS-I2T0-SSDSC2KB480G8; 3.8TB, Intel D3-S4610, 3 DWPD 480GB, Intel D3-S4510, <2 DWPD; SAS SSD; HDS-H2A1-WUSTR1548ASS200 HDS-X2A-XS400ME70004; 480GB, WDC/HGST Ultrastar SS530, 1 DWPD 400GB, Seagate Lange, 10 DWPD; Storage Control Card and Cable(s); AOC-S3108L-H8iR-16DD & 2x CBL-SAST-0593; Std LP, 8 internal ports, 12Gb/s per port- Gen3, 240HDD, RAID 0, 1, 5, 6, 10, 50, 60; MINI SAS HD,12G,INT,60CM,30AWG; Network Card(s); AOC-S25G-m2S AOC-S100G-M2C; Standard LP, 2x 25GbE SFP28, Mellanox ConnectX-4 LX EN Standard LP, 2x 100GbE QSFP28, Mellanox ConnectX-4 LX EN; TPM security module; AOM-TPM-9670H-S; TCG 2.0 compliant trusted platform module (TPM), Horizontal FF; Ultra Riser Card; AOC-URN4-m2TS & MCP-240-81915-0N AOC-URN4-b2XT & MCP-240-81909-0N AOC-URN4; 2-port 25GbE SFP28, Mellanox CX-4 Lx EN 2-port 10GbE RJ45, Broadcom BCM57416 No Onboard NIC; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; P4X-CLX6230R-SRGZA; Intel Xeon Gold 6230R Processor, 26 Cores, 2.10GHz, 36MB, 150W; Memory; MEM-DR464L-CL01-ER29 MEM-DR464L-HL02-ER29 MEM-DR432L-HL01-ER29 MEM-DR432L-SL01-ER29 MEM-DR432L-CL01-ER29 MEM-DR416L-CL01-ER29 MEM-DR416L-HL04-ER29; 64GB, DDR4-2933, RDIMM, Micron 64GB, DDR4-2933, RDIMM, Hynix 32GB, DDR4-2933, RDIMM, Hynix 32GB, DDR4-2933, RDIMM, Samsung 32GB, DDR4-2933, RDIMM, Micron 16GB, DDR4-2933, RDIMM, Micron 16GB, DDR4-2933, RDIMM, Hynix; NVMe SSD; HDS-2VD-MTFDHAL11TTCW1AR HDS-SUN0-MZWLL6T4HMLA05 HDS-S2T1-MZ7LH3T8HMLT05 HDS-SUN1-MZQLB3T8HALS07 HDS-IUN2-SSDPE2KX020T8 HDS-IUN0-SSDPE2KE016T8 HDS-MMN-MTFDHBA256TCK1AS; 11TB, Micron 9200 ECO, <1 DWPD 6.4TB, Samsung PM1725B, 3 DWPD 3.84TB, Samsung PM883, 1.3 DWPD 3.84 TB, Samsung PM983, 1.3 DWPD 2TB, Intel P4510, 1 DWPD 1.6TB, Intel P4610, 3 DWPD Micron 2200 256GB NVMe PCIe3.0x4 TLC M.2 22x80mm; Riser Card; RSC-UMR-8 RSC-R1UW-2E16 RSC-R1UW-E8R; 1U Ultra RHS Riser Card with 1 PCIE/SATA Hybrid M.2 &1 PCIE 1U LHS WIO Riser card with two PCI-E x16 slots 1U RHS WIO Riser card with one PCI-E x8 slot; SATA SSD; HDS-I2T0-SSDSC2KG038T8 HDS-I2T0-SSDSC2KB480G8; 3.8TB, Intel D3-S4610, 3 DWPD 480GB, Intel D3-S4510, <2 DWPD; SAS SSD; HDS-H2A1-WUSTR1548ASS200 HDS-X2A-XS400ME70004; 480GB, WDC/HGST Ultrastar SS530, 1 DWPD 400GB, Seagate Lange, 10 DWPD; Storage Control Card and Cable(s); AOC-S3108L-H8iR-16DD & 2x CBL-SAST-0593; Std LP, 8 internal ports, 12Gb/s per port- Gen3, 240HDD, RAID 0, 1, 5, 6, 10, 50, 60; MINI SAS HD,12G,INT,60CM,30AWG; Network Card(s); AOC-S25G-m2S AOC-S100G-M2C; Standard LP, 2x 25GbE SFP28, Mellanox ConnectX-4 LX EN Standard LP, 2x 100GbE QSFP28, Mellanox ConnectX-4 LX EN; TPM security module; AOM-TPM-9670H-S; TCG 2.0 compliant trusted platform module (TPM), Horizontal FF; Ultra Riser Card; AOC-URN4-m2TS & MCP-240-81915-0N AOC-URN4-b2XT & MCP-240-81909-0N AOC-URN4; 2-port 25GbE SFP28, Mellanox CX-4 Lx EN 2-port 10GbE RJ45, Broadcom BCM57416 No Onboard NIC; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; P4X-CLX6230R-SRGZA; Intel Xeon Gold 6230R Processor, 26 Cores, 2.10GHz, 36MB, 150W; Memory; MEM-DR464L-CL01-ER29 MEM-DR464L-HL02-ER29 MEM-DR432L-HL01-ER29 MEM-DR432L-SL01-ER29 MEM-DR432L-CL01-ER29 MEM-DR416L-CL01-ER29 MEM-DR416L-HL04-ER29; 64GB, DDR4-2933, RDIMM, Micron 64GB, DDR4-2933, RDIMM, Hynix 32GB, DDR4-2933, RDIMM, Hynix 32GB, DDR4-2933, RDIMM, Samsung 32GB, DDR4-2933, RDIMM, Micron 16GB, DDR4-2933, RDIMM, Micron 16GB, DDR4-2933, RDIMM, Hynix; NVMe SSD; HDS-2VD-MTFDHAL11TTCW1AR HDS-SUN0-MZWLL6T4HMLA05 HDS-S2T1-MZ7LH3T8HMLT05 HDS-SUN1-MZQLB3T8HALS07 HDS-IUN2-SSDPE2KX020T8 HDS-IUN0-SSDPE2KE016T8 HDS-MMN-MTFDHBA256TCK1AS; 11TB, Micron 9200 ECO, <1 DWPD 6.4TB, Samsung PM1725B, 3 DWPD 3.84TB, Samsung PM883, 1.3 DWPD 3.84 TB, Samsung PM983, 1.3 DWPD 2TB, Intel P4510, 1 DWPD 1.6TB, Intel P4610, 3 DWPD Micron 2200 256GB NVMe PCIe3.0x4 TLC M.2 22x80mm; Riser Card; RSC-UMR-8 RSC-R1UW-2E16 RSC-R1UW-E8R; 1U Ultra RHS Riser Card with 1 PCIE/SATA Hybrid M.2 &1 PCIE 1U LHS WIO Riser card with two PCI-E x16 slots 1U RHS WIO Riser card with one PCI-E x8 slot; SATA SSD; HDS-I2T0-SSDSC2KG038T8 HDS-I2T0-SSDSC2KB480G8; 3.8TB, Intel D3-S4610, 3 DWPD 480GB, Intel D3-S4510, <2 DWPD; SAS SSD; HDS-H2A1-WUSTR1548ASS200 HDS-X2A-XS400ME70004; 480GB, WDC/HGST Ultrastar SS530, 1 DWPD 400GB, Seagate Lange, 10 DWPD; Storage Control Card and Cable(s); AOC-S3108L-H8iR-16DD & 2x CBL-SAST-0593; Std LP, 8 internal ports, 12Gb/s per port- Gen3, 240HDD, RAID 0, 1, 5, 6, 10, 50, 60; MINI SAS HD,12G,INT,60CM,30AWG; Network Card(s); AOC-S25G-m2S AOC-S100G-M2C; Standard LP, 2x 25GbE SFP28, Mellanox ConnectX-4 LX EN Standard LP, 2x 100GbE QSFP28, Mellanox ConnectX-4 LX EN; TPM security module; AOM-TPM-9670H-S; TCG 2.0 compliant trusted platform module (TPM), Horizontal FF; Ultra Riser Card; AOC-URN4-m2TS & MCP-240-81915-0N AOC-URN4-b2XT & MCP-240-81909-0N AOC-URN4; 2-port 25GbE SFP28, Mellanox CX-4 Lx EN 2-port 10GbE RJ45, Broadcom BCM57416 No Onboard NIC; Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license) |
Отзывы
Загрузка отзывов...
Добавить отзыв
Оплачивайте покупки удобным способом. В интернет-магазине доступно 3 варианта оплаты:
- Наличные при самовывозе или доставке курьером. Специалист свяжется с вами в день доставки, чтобы уточнить время и заранее подготовить сдачу с любой купюры. Вы подписываете товаросопроводительные документы, вносите денежные средства, получаете товар и чек.
- Безналичный расчет при самовывозе или оформлении в интернет-магазине: карты МИР, Visa и MasterCard. Чтобы оплатить покупку, система перенаправит вас на сервер системы ASSIST. Здесь нужно ввести номер карты, срок действия и имя держателя.
- ЮMoney при онлайн-заказе. Для совершения покупки система перенаправит вас на страницу платежного сервиса. Здесь необходимо заполнить форму по инструкции.
Экономьте время на получении заказа. В интернет-магазине доступно 4 варианта доставки:
- Курьерская доставка работает с 9.00 до 19.00. Когда товар поступит на склад, курьерская служба свяжется для уточнения деталей. Специалист предложит выбрать удобное время доставки и уточнит адрес. Осмотрите упаковку на целостность и соответствие указанной комплектации.
- Самовывоз из магазина. Список торговых точек для выбора появится в корзине. Когда заказ поступит на склад, вам придет уведомление. Для получения заказа обратитесь к сотруднику в кассовой зоне и назовите номер.
- Постамат. Когда заказ поступит на точку, на ваш телефон или e-mail придет уникальный код. Заказ нужно оплатить в терминале постамата. Срок хранения — 3 дня.
- Почтовая доставка через почту России. Когда заказ придет в отделение, на ваш адрес придет извещение о посылке. Перед оплатой вы можете оценить состояние коробки: вес, целостность. Вскрывать коробку самостоятельно вы можете только после оплаты заказа. Один заказ может содержать не больше 10 позиций и его стоимость не должна превышать 100 000 р.