| Motherboard | Super X10DRG-OT+-CPU; Super X10DRG-OT+-CPU; Super X10DRG-OT+-CPU; Super X10DRG-OT+-CPU |
| System Memory - Memory Capacity | 24x 288-pin DDR4 DIMM slots Up to 3TB † ECC 3DS LRDIMM, 1.5TB ECC RDIMM |
| System Memory - Memory Type | 2400 † /2133/1866/1600MHz ECC DDR4 SDRAM 72-bit |
| System Memory - DIMM Sizes | RDIMM: 64GB, 32GB, 16GB, 8GB, 4GB LRDIMM: 64GB, 32GB 3DS LRDIMM: 128GB |
| System Memory - Memory Voltage | 1.2 V |
| System Memory - Error Detection | Corrects single-bit errors |
| On-Board Devices - Chipset | Intel® C612 chipset |
| On-Board Devices - SATA | SATA3 (6Gbps) with RAID 0, 1, 5, 10 |
| On-Board Devices - IPMI | Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support ASPEED AST2400 BMC |
| On-Board Devices - Network Controllers | Dual 10GBase-T Ports with Intel® X540 Virtual Machine Device Queues reduce I/O overhead Supports 10GBASE-T, 100BASE-TX, and 1000BASE-T, RJ45 output |
| Input Output - SATA | 10 SATA3 (6Gbps) ports |
| Input Output - LAN | 2 RJ45 10GBase-T LAN ports 1 RJ45 Dedicated IPMI LAN port |
| Input Output - USB | 4 USB 3.0 ports |
| Input Output - Video | 1 VGA Connector |
| PC Health Monitoring - FAN | 4-pin fan headers with tachometer status monitoring Low noise fan speed control mode |
| PC Health Monitoring - Temperature | Monitoring for CPU and system environment Thermal Control for 8 fan connectors |
| PC Health Monitoring - Other Features | Chassis intrusion detection |
| Chassis - Form Factor | 4U Rackmountable Rackmount Kit (MCP-290-00057-0N) |
| Chassis - Model | CSE-418GTS-R4000B |
| Expansion Slots - PCI-Express | 11 PCI-E 3.0 x16 (FH, FL) slots 1 PCI-E 3.0 x8 (in x16) slots Single Root Complex |
| Drive Bays - Hot-swap | 24 Hot-swap 2.5" hard drive bays |
| Backplane | SAS/SATA HDD Backplane; SAS/SATA HDD Backplane; SAS/SATA HDD Backplane; SAS/SATA HDD Backplane |
| System Cooling - Fans | 8 Hot-swap 92mm cooling fans |
| Power Supply | 2000W Redundant Power Supplies with PMBus; 2000W Redundant Power Supplies with PMBus; 2000W Redundant Power Supplies with PMBus; 2000W Redundant Power Supplies with PMBus |
| Power Supply - 12V | Max: 83.3A / Min: 0A (100-120Vac) Max: 150A / Min: 0A (200-220Vac) Max: 165A / Min: 0A (220-230Vac) Max: 166.7A / Min: 0A (230-240Vac) Max: 166.7A / Min: 0A (200-240Vac) (UL/cUL only) |
| Power Supply - Certification | Titanium Level [ Test Report ] |
| System BIOS - BIOS Type | 128Mb SPI Flash EEPROM with AMI® BIOS |
| Operating Environment Compliance - RoHS | RoHS Compliant |
| Operating Environment Compliance - Environmental Spec | Operating Temperature: 10°C to 35°C (50°F to 95°F) Non-operating Temperature: -40°C to 70°C (-40°F to 158°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) |
| Parts List - Items Included | Part Number; Description; Motherboard / Chassis; MBD-X10DRG-OT+-CPU MBD-X10DRG-O-PCIE CSE-418GTS-R4000B; Super X10DRG-OT+-CPU Motherboard Super X10DRG-O-PCIE Motherboard CSE-418GTS-R4000B Chassis; Air Shroud; MCP-310-41808-0B; Mylar PCIe air shroud for SC418G; Backplane; BPN-SAS3-216A; 24-port 2U SAS3 12Gbps direct-attached backplane, support up to 24x 2.5-inch SAS3/SATA3 HDD/SSD; Cable 1; CBL-SAST-0591; MINI SAS HD-4 SATA,6G,INT,RF,Cross Over,75CM,75CM SB,30AWG; Cable 2; CBL-0449L; HDD power extension for X8OBN, special 8 pin to 4 HDD. 45cm. 18AWG; Cable 3; CBL-PWEX-0582; 8 pin to two 6+2 pin 12V GPU power cable, 30 cm 16/20 AWG, 10A/pin(16AWG), 6A/pin(20AWG), -25~85C, RoHS/REACH; LBL-0108; CAUTION LABEL FOR REDUNDANT PWR SYSTEMS; Manual; MNL-1800-QRG; SYS-4028GR-TR(T) Quick Reference Guide,HF,RoHS/REACH; Riser Card; RSC-X9DRG-O; RSC-X9DRG-O; Heatsink / Retention; SNK-P0048PS; 2U Passive CPU Heat Sink for X9, X10 Generation Systems Equipped w/ a Narrow ILM MB; Power Supply; PWS-2K05A-1R; 1U 2000W Redundant Titanium Power Supply W/PMbus 73.5x40x265mm,RoHS/REACH; Part Number; Description; Motherboard / Chassis; MBD-X10DRG-OT+-CPU MBD-X10DRG-O-PCIE CSE-418GTS-R4000B; Super X10DRG-OT+-CPU Motherboard Super X10DRG-O-PCIE Motherboard CSE-418GTS-R4000B Chassis; Air Shroud; MCP-310-41808-0B; Mylar PCIe air shroud for SC418G; Backplane; BPN-SAS3-216A; 24-port 2U SAS3 12Gbps direct-attached backplane, support up to 24x 2.5-inch SAS3/SATA3 HDD/SSD; Cable 1; CBL-SAST-0591; MINI SAS HD-4 SATA,6G,INT,RF,Cross Over,75CM,75CM SB,30AWG; Cable 2; CBL-0449L; HDD power extension for X8OBN, special 8 pin to 4 HDD. 45cm. 18AWG; Cable 3; CBL-PWEX-0582; 8 pin to two 6+2 pin 12V GPU power cable, 30 cm 16/20 AWG, 10A/pin(16AWG), 6A/pin(20AWG), -25~85C, RoHS/REACH; LBL-0108; CAUTION LABEL FOR REDUNDANT PWR SYSTEMS; Manual; MNL-1800-QRG; SYS-4028GR-TR(T) Quick Reference Guide,HF,RoHS/REACH; Riser Card; RSC-X9DRG-O; RSC-X9DRG-O; Heatsink / Retention; SNK-P0048PS; 2U Passive CPU Heat Sink for X9, X10 Generation Systems Equipped w/ a Narrow ILM MB; Power Supply; PWS-2K05A-1R; 1U 2000W Redundant Titanium Power Supply W/PMbus 73.5x40x265mm,RoHS/REACH; Part Number; Description; Motherboard / Chassis; MBD-X10DRG-OT+-CPU MBD-X10DRG-O-PCIE CSE-418GTS-R4000B; Super X10DRG-OT+-CPU Motherboard Super X10DRG-O-PCIE Motherboard CSE-418GTS-R4000B Chassis; Air Shroud; MCP-310-41808-0B; Mylar PCIe air shroud for SC418G; Backplane; BPN-SAS3-216A; 24-port 2U SAS3 12Gbps direct-attached backplane, support up to 24x 2.5-inch SAS3/SATA3 HDD/SSD; Cable 1; CBL-SAST-0591; MINI SAS HD-4 SATA,6G,INT,RF,Cross Over,75CM,75CM SB,30AWG; Cable 2; CBL-0449L; HDD power extension for X8OBN, special 8 pin to 4 HDD. 45cm. 18AWG; Cable 3; CBL-PWEX-0582; 8 pin to two 6+2 pin 12V GPU power cable, 30 cm 16/20 AWG, 10A/pin(16AWG), 6A/pin(20AWG), -25~85C, RoHS/REACH; LBL-0108; CAUTION LABEL FOR REDUNDANT PWR SYSTEMS; Manual; MNL-1800-QRG; SYS-4028GR-TR(T) Quick Reference Guide,HF,RoHS/REACH; Riser Card; RSC-X9DRG-O; RSC-X9DRG-O; Heatsink / Retention; SNK-P0048PS; 2U Passive CPU Heat Sink for X9, X10 Generation Systems Equipped w/ a Narrow ILM MB; Power Supply; PWS-2K05A-1R; 1U 2000W Redundant Titanium Power Supply W/PMbus 73.5x40x265mm,RoHS/REACH; Part Number; Description; Motherboard / Chassis; MBD-X10DRG-OT+-CPU MBD-X10DRG-O-PCIE CSE-418GTS-R4000B; Super X10DRG-OT+-CPU Motherboard Super X10DRG-O-PCIE Motherboard CSE-418GTS-R4000B Chassis; Air Shroud; MCP-310-41808-0B; Mylar PCIe air shroud for SC418G; Backplane; BPN-SAS3-216A; 24-port 2U SAS3 12Gbps direct-attached backplane, support up to 24x 2.5-inch SAS3/SATA3 HDD/SSD; Cable 1; CBL-SAST-0591; MINI SAS HD-4 SATA,6G,INT,RF,Cross Over,75CM,75CM SB,30AWG; Cable 2; CBL-0449L; HDD power extension for X8OBN, special 8 pin to 4 HDD. 45cm. 18AWG; Cable 3; CBL-PWEX-0582; 8 pin to two 6+2 pin 12V GPU power cable, 30 cm 16/20 AWG, 10A/pin(16AWG), 6A/pin(20AWG), -25~85C, RoHS/REACH; LBL-0108; CAUTION LABEL FOR REDUNDANT PWR SYSTEMS; Manual; MNL-1800-QRG; SYS-4028GR-TR(T) Quick Reference Guide,HF,RoHS/REACH; Riser Card; RSC-X9DRG-O; RSC-X9DRG-O; Heatsink / Retention; SNK-P0048PS; 2U Passive CPU Heat Sink for X9, X10 Generation Systems Equipped w/ a Narrow ILM MB; Power Supply; PWS-2K05A-1R; 1U 2000W Redundant Titanium Power Supply W/PMbus 73.5x40x265mm,RoHS/REACH |
| Optional Parts List | Part Number; Description; CBL-PWEX-0665; PCIe 8 pin female(black) to CPU 8 pin female(white), K80/M60/M40/P100/P40 GPU power for 300W card, 30cm, 18AWG; Add-on Card Dummy; MCP-240-00096-0N; GPU / Add-on Card Dummy Assembly (2 Slots)-Single Pack; Bracket; MCP-120-00016-00; Blank FH L-bracket (with Tesla P4); Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; CBL-PWEX-0665; PCIe 8 pin female(black) to CPU 8 pin female(white), K80/M60/M40/P100/P40 GPU power for 300W card, 30cm, 18AWG; Add-on Card Dummy; MCP-240-00096-0N; GPU / Add-on Card Dummy Assembly (2 Slots)-Single Pack; Bracket; MCP-120-00016-00; Blank FH L-bracket (with Tesla P4); Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; CBL-PWEX-0665; PCIe 8 pin female(black) to CPU 8 pin female(white), K80/M60/M40/P100/P40 GPU power for 300W card, 30cm, 18AWG; Add-on Card Dummy; MCP-240-00096-0N; GPU / Add-on Card Dummy Assembly (2 Slots)-Single Pack; Bracket; MCP-120-00016-00; Blank FH L-bracket (with Tesla P4); Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; CBL-PWEX-0665; PCIe 8 pin female(black) to CPU 8 pin female(white), K80/M60/M40/P100/P40 GPU power for 300W card, 30cm, 18AWG; Add-on Card Dummy; MCP-240-00096-0N; GPU / Add-on Card Dummy Assembly (2 Slots)-Single Pack; Bracket; MCP-120-00016-00; Blank FH L-bracket (with Tesla P4); Global Services & Support; OS4HR3/2/1 OSNBD3/2/1; 3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license) |
| ProcessorCache - CPU | Intel® Xeon® processor E5-2600 v4 † / v3 family (up to 160W TDP) * Dual Socket R3 (LGA 2011) |
| ProcessorCache - Note | * Please contact Supermicro Technical Support for additional information about frequency optimized CPUs and specialized system optimization. |
| System BIOS - BIOS Features | Plug and Play (PnP) APM 1.2 DMI 2.3 PCI 2.3 ACPI 1.0 / 2.0 / 3.0 USB Keyboard support SMBIOS 2.7.1 UEFI |
| On-Board Devices - Graphics | ASPEED AST2400 BMC |
| Dimensions - Width | 17.2" (437mm) |
| Dimensions - Height | 7.0" (178mm) |
| Dimensions - Depth | 29" (737mm) |
| Dimensions - Weight | Net Weight: 65.5 lbs (29.7 kg) Gross Weight: 100 lbs (45.3 kg) |
| Dimensions - Available Colors | Black |
| PC Health Monitoring - CPU | Monitors for CPU Cores, +1.2V, 1.5V, +3.3V, +12V, (+3V, 1.0V, 1.2V, 1.8V, 1.1V) Standby, VBAT, Memory, Chipset Voltages. 4-Phase-switching voltage regulator with auto-sense from 0.6V-1.35V |
| Input Output - Serial Port | 1 Serial header |
| Power Supply - Total Output Power | 1000W: 100 – 120Vac 1800W: 200 – 220Vac 1980W: 220 – 230Vac 2000W: 230 – 240Vac 2000W: 200 – 240Vac (UL/CUL only) |
| Power Supply - DimensionW x H x L | 73.5 x 40 x 265 mm |
| Power Supply - Input | 100-120Vac / 12.5-9.5A / 50-60Hz 200-220Vac / 10-9.5A / 50-60Hz 220-230Vac / 10-9.8A / 50-60Hz 230-240Vac / 10-9.8A / 50-60Hz 200-240Vac / 11.8-9.8A / 50-60Hz (UL/cUL only) |
| Power Supply - 12Vsb | Max: 2.1A / Min: 0A |
| Power Supply - Output Type | 25 Pairs Gold Finger Connector |
| ProcessorCache - Cores Cache | Up to 22 Cores † / Up to 55MB † Cache |
| ProcessorCache - System Bus | QPI up to 9.6 GT/s |
| System Cooling - Shrouds | 1 Air Shroud (MCP-310-41808-0B) |
| Product SKUs - SYS-4028GR-TRT2 | SuperServer 4028GR-TRT2 ( Black ) |
Отзывы
Загрузка отзывов...
Добавить отзыв
Оплачивайте покупки удобным способом. В интернет-магазине доступно 3 варианта оплаты:
- Наличные при самовывозе или доставке курьером. Специалист свяжется с вами в день доставки, чтобы уточнить время и заранее подготовить сдачу с любой купюры. Вы подписываете товаросопроводительные документы, вносите денежные средства, получаете товар и чек.
- Безналичный расчет при самовывозе или оформлении в интернет-магазине: карты МИР, Visa и MasterCard. Чтобы оплатить покупку, система перенаправит вас на сервер системы ASSIST. Здесь нужно ввести номер карты, срок действия и имя держателя.
- ЮMoney при онлайн-заказе. Для совершения покупки система перенаправит вас на страницу платежного сервиса. Здесь необходимо заполнить форму по инструкции.
Экономьте время на получении заказа. В интернет-магазине доступно 4 варианта доставки:
- Курьерская доставка работает с 9.00 до 19.00. Когда товар поступит на склад, курьерская служба свяжется для уточнения деталей. Специалист предложит выбрать удобное время доставки и уточнит адрес. Осмотрите упаковку на целостность и соответствие указанной комплектации.
- Самовывоз из магазина. Список торговых точек для выбора появится в корзине. Когда заказ поступит на склад, вам придет уведомление. Для получения заказа обратитесь к сотруднику в кассовой зоне и назовите номер.
- Постамат. Когда заказ поступит на точку, на ваш телефон или e-mail придет уникальный код. Заказ нужно оплатить в терминале постамата. Срок хранения — 3 дня.
- Почтовая доставка через почту России. Когда заказ придет в отделение, на ваш адрес придет извещение о посылке. Перед оплатой вы можете оценить состояние коробки: вес, целостность. Вскрывать коробку самостоятельно вы можете только после оплаты заказа. Один заказ может содержать не больше 10 позиций и его стоимость не должна превышать 100 000 р.