| Motherboard | Super X11DPFR-SN; Super X11DPFR-SN; Super X11DPFR-SN; Super X11DPFR-SN |
| On-Board Devices - Chipset | Intel® C621 chipset |
| On-Board Devices - IPMI | Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support |
| On-Board Devices - Network Controllers | Flexible networking via SIOM |
| PC Health Monitoring - FAN | Fans with tachometer monitoring Status monitor for speed control Pulse Width Modulated (PWM) fan connectors |
| PC Health Monitoring - Temperature | Monitoring for CPU and chassis environment Thermal Control for fan connectors |
| Chassis - Form Factor | 4U Rackmount |
| Chassis - Model | CSE-F424AS2-R1K23BP |
| Dimensions and Weight - Height | 6.96" (177mm) |
| Dimensions and Weight - Width | 17.63" (448mm) |
| Dimensions and Weight - Depth | 29" (737mm) |
| Dimensions and Weight - Package | 28.3" (W) x 15.0" (H) x 42.4" (D) |
| Dimensions and Weight - Weight | Net Weight: 150 lbs (68.04 kg) Gross Weight: 200 lbs (90.71 kg) |
| Dimensions and Weight - Available Colors | Black |
| Front Panel - Buttons | Power On/Off button UID button |
| Front Panel - LEDs | Power status LED Hard drive activity LED Network activity LEDs Information LED (UID, Fan failure, Overheat) |
| Backplane | 1 SAS/SATA backplane; 1 SAS/SATA backplane; 1 SAS/SATA backplane; 1 SAS/SATA backplane |
| System BIOS - BIOS Type | 128Mb SPI Flash EEPROM with AMI BIOS |
| Parts List - Items Included | Part Number; Description; Motherboard / Chassis; MBD-X11DPFR-SN CSE-F424AS2-R1K23BP; Super X11DPFR-SN Motherboard 4U Chassis; Backplane; BPN-ADP-8S3008-1UF; BPN-ADP-8S3008-1UF; Backplane; BPN-ADP-X11DPFR; Power distribution board for X11DPFR-S(N); Backplane; BPN-SAS3-F424-A2N2A; 2-Port Hybrid Backplane support 2 x SAS3/SATA3/NVMe Storage Devices; Backplane; BPN-SAS3-F424-A6; 6-port Fat Twin SAS3 12Gbps backplane, support up to 6x 3.5-inch SAS3/SATA3 HDD/SSD; Cable 1; CBL-0486L; 2x2 to 2x2 15cm power cable HF. 18AWG; Cable 2; CBL-OTHR-0022L; 20 to 20 pin cable for BPN-ADP-F418LS,7.5cm, 28AWG,RoHS/REACH,PBF; Cable 3; CBL-PWCD-0900; PWCD,US/EU/Canada/China/Australia,IEC60320 C14 TO C13,4FT,17AWG; Cable 4; CBL-SAST-0691; MINI SAS HD RA- 2x MINI SAS HD,INT,15/59CM,28AWG; Cable 5; CBL-SAST-0706; MINI SAS HD (reversed RA)-MINI SAS HD,12G,INT,11CM,30AWG; Heatsink / Retention; SNK-P0068PSC; 2U Passive CPU Heat Sink with a Side Air Channel for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Heatsink / Retention; SNK-P0069PSC; 1.5U Proprietary 50-mm Tall Passive CPU Heat Sink with a Side Air Channel for X11 Purley Platform 2U Node Twin Series Servers; Power Supply; PWS-1K23A-1R; AC-DC 1200W, Titanium Level, Redundancy, 1U, PMBUS 1.2, +12V/+5Vsb, 360x76x40 mm,HF,RoHS/REACH; Part Number; Description; Motherboard / Chassis; MBD-X11DPFR-SN CSE-F424AS2-R1K23BP; Super X11DPFR-SN Motherboard 4U Chassis; Backplane; BPN-ADP-8S3008-1UF; BPN-ADP-8S3008-1UF; Backplane; BPN-ADP-X11DPFR; Power distribution board for X11DPFR-S(N); Backplane; BPN-SAS3-F424-A2N2A; 2-Port Hybrid Backplane support 2 x SAS3/SATA3/NVMe Storage Devices; Backplane; BPN-SAS3-F424-A6; 6-port Fat Twin SAS3 12Gbps backplane, support up to 6x 3.5-inch SAS3/SATA3 HDD/SSD; Cable 1; CBL-0486L; 2x2 to 2x2 15cm power cable HF. 18AWG; Cable 2; CBL-OTHR-0022L; 20 to 20 pin cable for BPN-ADP-F418LS,7.5cm, 28AWG,RoHS/REACH,PBF; Cable 3; CBL-PWCD-0900; PWCD,US/EU/Canada/China/Australia,IEC60320 C14 TO C13,4FT,17AWG; Cable 4; CBL-SAST-0691; MINI SAS HD RA- 2x MINI SAS HD,INT,15/59CM,28AWG; Cable 5; CBL-SAST-0706; MINI SAS HD (reversed RA)-MINI SAS HD,12G,INT,11CM,30AWG; Heatsink / Retention; SNK-P0068PSC; 2U Passive CPU Heat Sink with a Side Air Channel for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Heatsink / Retention; SNK-P0069PSC; 1.5U Proprietary 50-mm Tall Passive CPU Heat Sink with a Side Air Channel for X11 Purley Platform 2U Node Twin Series Servers; Power Supply; PWS-1K23A-1R; AC-DC 1200W, Titanium Level, Redundancy, 1U, PMBUS 1.2, +12V/+5Vsb, 360x76x40 mm,HF,RoHS/REACH; Part Number; Description; Motherboard / Chassis; MBD-X11DPFR-SN CSE-F424AS2-R1K23BP; Super X11DPFR-SN Motherboard 4U Chassis; Backplane; BPN-ADP-8S3008-1UF; BPN-ADP-8S3008-1UF; Backplane; BPN-ADP-X11DPFR; Power distribution board for X11DPFR-S(N); Backplane; BPN-SAS3-F424-A2N2A; 2-Port Hybrid Backplane support 2 x SAS3/SATA3/NVMe Storage Devices; Backplane; BPN-SAS3-F424-A6; 6-port Fat Twin SAS3 12Gbps backplane, support up to 6x 3.5-inch SAS3/SATA3 HDD/SSD; Cable 1; CBL-0486L; 2x2 to 2x2 15cm power cable HF. 18AWG; Cable 2; CBL-OTHR-0022L; 20 to 20 pin cable for BPN-ADP-F418LS,7.5cm, 28AWG,RoHS/REACH,PBF; Cable 3; CBL-PWCD-0900; PWCD,US/EU/Canada/China/Australia,IEC60320 C14 TO C13,4FT,17AWG; Cable 4; CBL-SAST-0691; MINI SAS HD RA- 2x MINI SAS HD,INT,15/59CM,28AWG; Cable 5; CBL-SAST-0706; MINI SAS HD (reversed RA)-MINI SAS HD,12G,INT,11CM,30AWG; Heatsink / Retention; SNK-P0068PSC; 2U Passive CPU Heat Sink with a Side Air Channel for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Heatsink / Retention; SNK-P0069PSC; 1.5U Proprietary 50-mm Tall Passive CPU Heat Sink with a Side Air Channel for X11 Purley Platform 2U Node Twin Series Servers; Power Supply; PWS-1K23A-1R; AC-DC 1200W, Titanium Level, Redundancy, 1U, PMBUS 1.2, +12V/+5Vsb, 360x76x40 mm,HF,RoHS/REACH; Part Number; Description; Motherboard / Chassis; MBD-X11DPFR-SN CSE-F424AS2-R1K23BP; Super X11DPFR-SN Motherboard 4U Chassis; Backplane; BPN-ADP-8S3008-1UF; BPN-ADP-8S3008-1UF; Backplane; BPN-ADP-X11DPFR; Power distribution board for X11DPFR-S(N); Backplane; BPN-SAS3-F424-A2N2A; 2-Port Hybrid Backplane support 2 x SAS3/SATA3/NVMe Storage Devices; Backplane; BPN-SAS3-F424-A6; 6-port Fat Twin SAS3 12Gbps backplane, support up to 6x 3.5-inch SAS3/SATA3 HDD/SSD; Cable 1; CBL-0486L; 2x2 to 2x2 15cm power cable HF. 18AWG; Cable 2; CBL-OTHR-0022L; 20 to 20 pin cable for BPN-ADP-F418LS,7.5cm, 28AWG,RoHS/REACH,PBF; Cable 3; CBL-PWCD-0900; PWCD,US/EU/Canada/China/Australia,IEC60320 C14 TO C13,4FT,17AWG; Cable 4; CBL-SAST-0691; MINI SAS HD RA- 2x MINI SAS HD,INT,15/59CM,28AWG; Cable 5; CBL-SAST-0706; MINI SAS HD (reversed RA)-MINI SAS HD,12G,INT,11CM,30AWG; Heatsink / Retention; SNK-P0068PSC; 2U Passive CPU Heat Sink with a Side Air Channel for X11 Purley Platform Equipped with a Narrow Retention Mechanism; Heatsink / Retention; SNK-P0069PSC; 1.5U Proprietary 50-mm Tall Passive CPU Heat Sink with a Side Air Channel for X11 Purley Platform 2U Node Twin Series Servers; Power Supply; PWS-1K23A-1R; AC-DC 1200W, Titanium Level, Redundancy, 1U, PMBUS 1.2, +12V/+5Vsb, 360x76x40 mm,HF,RoHS/REACH |
| Optional Parts List | Part Number; Description; Backplane; BPN-ADP-2UPWR-X11; 1 per node for configurations with CPU at 145W or higher; CBL-0480L; 1 per node for configurations with CPU at 145W or higher; Contact Supermicro for configurations with more NVMe SSDs.; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; Backplane; BPN-ADP-2UPWR-X11; 1 per node for configurations with CPU at 145W or higher; CBL-0480L; 1 per node for configurations with CPU at 145W or higher; Contact Supermicro for configurations with more NVMe SSDs.; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; Backplane; BPN-ADP-2UPWR-X11; 1 per node for configurations with CPU at 145W or higher; CBL-0480L; 1 per node for configurations with CPU at 145W or higher; Contact Supermicro for configurations with more NVMe SSDs.; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license); Part Number; Description; Backplane; BPN-ADP-2UPWR-X11; 1 per node for configurations with CPU at 145W or higher; CBL-0480L; 1 per node for configurations with CPU at 145W or higher; Contact Supermicro for configurations with more NVMe SSDs.; Software; SFT-OOB-LIC •; OOB Management Package (per node license); Software; SFT-DCMS-Single; DataCenter Management Package (per node license) |
| On-Board Devices - SAS | SAS3 (12Gbps) via Broadcom 3008 |
| Management - Software | Intel® Node Manager IPMI 2.0 KVM with dedicated LAN SuperDoctor® 5 Watch Dog |
| Management - Power Configurations | ACPI Power Management |
| On-Board Devices - Graphics | ASPEED AST2500 BMC |
| Expansion Slots per node - PCI-Express | 1 PCI-E 3.0 x16 (Low-profile) 1 PCI-E 3.0 x16 (SIOM) |
| Input Output per node - LAN | SIOM flexible Network card 1 RJ45 Dedicated IPMI LAN port |
| Power Supply 76mm Width | 1200W Redundant Power Supplies with PMBus; 1200W Redundant Power Supplies with PMBus; 1200W Redundant Power Supplies with PMBus; 1200W Redundant Power Supplies with PMBus |
| Power Supply 76mm Width - Total Output Power | 1000W/1200W |
| Power Supply 76mm Width - DimensionW x H x L | 76 x 40 x 336 mm |
| Power Supply 76mm Width - Input | 100-127Vac / 15-12A / 50-60Hz 200-240Vac / 8.5-7A / 50-60Hz 200-240Vdc / 8.5-7A (for CCC only) |
| Power Supply 76mm Width - 12V | Max: 83A / Min: 0A (100-127Vac) Max: 100A / Min: 0A (200-240Vac) Max: 100A / Min: 0A (200-240Vdc) |
| Power Supply 76mm Width - 5Vsb | Max: 4A / Min: 0A |
| Power Supply 76mm Width - Output Type | 19 Pairs Gold Finger Connector |
| Power Supply 76mm Width - Certification | Titanium Level [ Test Report ] |
| PC Health Monitoring - CPU | Monitors for CPU Cores, Chipset Voltages, Memory. 4+1 Phase-switching voltage regulator |
| Operating Environment - RoHS | RoHS Compliant |
| Operating Environment - Environmental Spec | Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F) Non-operating Temperature: -40°C to 60°C (-40°F to 140°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) |
| System Memory per Node - Memory Capacity | 12 DIMM slots Up to 3TB 3DS ECC DDR4-2933MHz † RDIMM/LRDIMM Supports Intel® Optane™ DCPMM †† |
| System Memory per Node - Memory Type | 2933 † /2666/2400/2133MHz ECC DDR4 RDIMM/LRDIMM |
| System Memory per Node - Note | † 2933MHz in two DIMMs per channel can be achieved by using memory purchased from Supermicro †† Cascade Lake only. Contact your Supermicro sales rep for more info. |
| Input Output per node - NVMe | 2 NVMe U.2 option |
| Input Output per node - USB | 2 USB 3.0 ports (rear) |
| Input Output per node - VGA | 1 VGA port |
| Drive Bays per node - Hot-swap | 8 Hot-swap 3.5" SAS3/SATA3 or 6 Hot-swap 3.5" SAS3/SATA3 + 2 optional NVMe U.2 |
| Drive Bays per node - M2 | M.2 Interface: PCI-E 3.0 x4 M.2 Form Factor: 2260, 2280, 22110 M.2 Key: M-Key |
| System Cooling per node - Fans | 2x 8cm 14 RPM middle fans |
| Processor per Node - CPU | Dual Socket P (LGA 3647) 2nd Gen Intel® Xeon® Scalable Processors and Intel® Xeon® Scalable Processors ‡ , Dual UPI up to 10.4GT/s Support CPU TDP 70-165W with IVR |
| Processor per Node - Cores | Up to 28 Cores |
| Processor per Node - Note | ‡ BIOS version 3.2 or above is required to support 2nd Gen Intel® Xeon® Scalable processors (codenamed Cascade Lake-R). Extended thermal solutions may be required to support CPUs higher than 165W TDP, please contact Supermicro Technical Support for additional information. |
| Input Output per node - SAS | 8 SAS3 (12Gbps) ports |
| Product SKUs - SYS-F629P3-RC0B | SuperServer F629P3-RC0B ( Black ) |
Отзывы
Загрузка отзывов...
Добавить отзыв
Оплачивайте покупки удобным способом. В интернет-магазине доступно 3 варианта оплаты:
- Наличные при самовывозе или доставке курьером. Специалист свяжется с вами в день доставки, чтобы уточнить время и заранее подготовить сдачу с любой купюры. Вы подписываете товаросопроводительные документы, вносите денежные средства, получаете товар и чек.
- Безналичный расчет при самовывозе или оформлении в интернет-магазине: карты МИР, Visa и MasterCard. Чтобы оплатить покупку, система перенаправит вас на сервер системы ASSIST. Здесь нужно ввести номер карты, срок действия и имя держателя.
- ЮMoney при онлайн-заказе. Для совершения покупки система перенаправит вас на страницу платежного сервиса. Здесь необходимо заполнить форму по инструкции.
Экономьте время на получении заказа. В интернет-магазине доступно 4 варианта доставки:
- Курьерская доставка работает с 9.00 до 19.00. Когда товар поступит на склад, курьерская служба свяжется для уточнения деталей. Специалист предложит выбрать удобное время доставки и уточнит адрес. Осмотрите упаковку на целостность и соответствие указанной комплектации.
- Самовывоз из магазина. Список торговых точек для выбора появится в корзине. Когда заказ поступит на склад, вам придет уведомление. Для получения заказа обратитесь к сотруднику в кассовой зоне и назовите номер.
- Постамат. Когда заказ поступит на точку, на ваш телефон или e-mail придет уникальный код. Заказ нужно оплатить в терминале постамата. Срок хранения — 3 дня.
- Почтовая доставка через почту России. Когда заказ придет в отделение, на ваш адрес придет извещение о посылке. Перед оплатой вы можете оценить состояние коробки: вес, целостность. Вскрывать коробку самостоятельно вы можете только после оплаты заказа. Один заказ может содержать не больше 10 позиций и его стоимость не должна превышать 100 000 р.